Physics-Based iOCT Sonification for Real-time Interaction Awareness in Subretinal Injection

Subretinal injection is a delicate vitreoretinal procedure requiring precise needle placement within the subretinal space while avoiding perforation of the retinal pigment epithelium (RPE), a layer directly beneath the target with extremely limited regenerative capacity. To enhance depth perception during cannula advancement, intraoperative optical coherence tomography (iOCT) offers high-resolution cross-sectional visualization of needle-tissue interaction; however, interpreting these images requires sustained visual attention alongside the en face microscope view, thereby increasing cognitive load during critical phases and placing additional demands on the surgeon's proprioceptive control. In this paper, we propose a structured, real-time sonification framework designed for extensible mapping of iOCT-derived anatomical features into perceptual auditory feedback. The method employs a physics-inspired acoustic model driven by segmented retinal layers from a stream of iOCT B-scans, with needle motion and injection-induced retinal layer displacements serving as excitation inputs to the sound model, enabling perception of tool position and retinal deformation. In a controlled user study (n=34), the proposed sonification achieved high retinal layer identification accuracy and robust detection of retinal deformation-related events, significantly outperforming a state-of-the-art baseline in overall event identification (83.4% vs. 60.6%, p < 0.001), with gains driven primarily by enhanced detection of injection-induced retinal deformation. Evaluation by experts (n=4) confirmed the clinical relevance and potential intraoperative applicability of the method. These results establish structured iOCT sonification as a viable complementary modality for real-time surgical guidance in subretinal injection.

cs.SD

Catheter Monitoring in Intelligent Endovascular Navigation Systems: Interactive Simulations and Mixed Reality for Enhanced Navigational Awareness

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter-vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was tested in-vitro using a sensorized catheter with Fiber Bragg Grating and electromagnetic sensors as it was advanced through a silicone replica of the vascular anatomy. Real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens 2. The performance and accuracy of FEM-computed vessel wall displacement were validated against experimental ground-truth obtained via stereo frames triangulation. Results: The simulated time exceeded the real temporal extent by 12% during initial navigation and by 45% when the catheter reached the most tortuous portion. Hololens 2 rendering remained stable at 35-40 frames per second. The median relative displacement error between FEM-computed and ground-truth vessel wall displacements remained below 1 mm and 2.33 mm for these two phases, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter-vessel interactions, with mixed reality visualization serving as a user interface to support operator decision-making.

cs.HC

Physics-driven Sonification for Improving Multisensory Needle Guidance in Percutaneous Epicardial Access

Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin and moving pericardium remains highly challenging and risky. To address this problem, we present a physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception during the critical needle landing phase in PEA. Dynamic cardiac anatomy from 4D CTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided the position of the needle tip relative to moving cardiac structures and drove an audio-visual feedback module. The visual display presented navigational cues and dynamic anatomy, while the auditory display encoded physiological cardiac states using a multilayer physical membrane model. A phantom study was conducted with twelve cardiologists performing needle insertions under visual-only and multisensory feedback. The multisensory method significantly improved navigation safety ($\chi^2 = 11.30$, $p < 0.01$), reducing myocardial contact (3.64% vs. 7.27%) and increasing correct access (90.91% vs. 52.73%). Needle placement accuracy improved, with closer membrane proximity (Cliff delta = 0.19) and reduced variability ($p < 0.05$). Execution time was comparable, while time-accuracy correlations differed significantly between modalities ($p < 0.01$). NASA-TLX indicated lower cognitive load with multisensory guidance ($p < 0.01$). These results demonstrate the feasibility of physics-driven sonification for improving spatiotemporal awareness and supporting user-centered surgical navigation.

cs.HC

BioSonix: Can Physics-Based Sonification Perceptualize Tissue Deformations From Tool Interactions?

Perceptualizing tool interactions with deformable structures in surgical procedures remains challenging, as unimodal visualization techniques often fail to capture the complexity of these interactions due to constraints such as occlusion and limited depth perception. This paper presents a novel approach to augment tool navigation in mixed reality environments by providing auditory representations of tool-tissue dynamics, particularly for interactions with soft tissue. BioSonix, a physics-informed design framework, utilizes tissue displacements in 3D space to compute excitation forces for a sound model encoding tissue properties such as stiffness and density. Biomechanical simulations were employed to model particle displacements resulting from tool-tissue interactions, establishing a robust foundation for the method. An optimization approach was used to define configurations for capturing diverse interaction scenarios with varying tool trajectories. Experiments were conducted to validate the accuracy of the sound-displacement mappings. Additionally, two user studies were performed: the first involved two clinical professionals (a neuroradiologist and a cardiologist), who confirmed the method's impact and achieved high task accuracy; the second included 22 biomedical experts, who demonstrated high discrimination accuracy in tissue differentiation and targeting tasks. The results revealed a strong correlation between tool-tissue dynamics and their corresponding auditory profiles, highlighting the potential of these sound representations to enhance the intuitive understanding of complex interactions.

cs.SD

MitraClip Device Automated Localization in 3D Transesophageal Echocardiography via Deep Learning

The MitraClip is the most widely percutaneous treatment for mitral regurgitation, typically performed under the real-time guidance of 3D transesophagel echocardiography (TEE). However, artifacts and low image contrast in echocardiography hinder accurate clip visualization. This study presents an automated pipeline for clip detection from 3D TEE images. An Attention UNet was employed to segment the device, while a DenseNet classifier predicted its configuration among ten possible states, ranging from fully closed to fully open. Based on the predicted configuration, a template model derived from computer-aided design (CAD) was automatically registered to refine the segmentation and enable quantitative characterization of the device. The pipeline was trained and validated on 196 3D TEE images acquired using a heart simulator, with ground-truth annotations refined through CAD-based templates. The Attention UNet achieved an average surface distance of 0.76 mm and 95% Hausdorff distance of 2.44 mm for segmentation, while the DenseNet achieved an average weighted F1-score of 0.75 for classification. Post-refinement, segmentation accuracy improved, with average surface distance and 95% Hausdorff distance reduced to 0.75 mm and 2.05 mm, respectively. This pipeline enhanced clip visualization, providing fast and accurate detection with quantitative feedback, potentially improving procedural efficiency and reducing adverse outcomes.

q-bio.QM