Publications and source records attributed to Vianak Naranjo.

5 recordsLinked to original sources

Charge migration characterization in the METIS H2RG detectors

The Mid-infrared ELT Imager and Spectrograph (METIS) is one of the first-light instruments of the Extremely Large Telescope (ELT). For the L and M band, the instrument makes use of Teledyne's H2RG detectors, known to be affected by charge migration, also known as the brighter-fatter effect (BFE). In the H2RG detectors this manifests as photo-electrons moving from a central bright pixel to neighboring pixels as the depletion region of the central pixel shrinks with accumulated charge. Due to its effect of `blurring' information, it especially affects direct imaging, transit, and high-resolution spectroscopy applications. We aim to characterize its effect in the METIS H2RG detectors, such that we can remove it without losing information.

astro-ph.IM

A 5kHz modulator for pyramid wavefront sensors

Despite the emergence of new types of wavefront sensors, the modulated pyramid wavefront sensor remains the workhorse for ELT instrumentation, and is among the options even for advanced high-contrast, high-Strehl instrumentation like PCS and SAXO+. To achieve the required degree of wavefront control, an operation at frequencies of 3kHz, ideally up to 5kHz, is necessary, requiring an optomechanical device capable of delivering accurate circular modulation patterns with these frequencies. Here, we present tests of a novel type of high-frequency modulator based on shearing piezo actuators. The modulator prototype moves a flat circular mirror (15mm diameter) with a tip-tilt range of plus/minus 50 arcsec. At a typical 10mm pupil diameter on the modulator mirror, and operating at 2.2$μ$m, this will create a modulation circle with a radius of slightly greater than 2 $λ$/D. While this is less than conventionally specified for most instruments, it should already be sufficient for any practical application except for very bad conditions or extended targets. We performed modulation tests at frequencies between 250 Hz to 5 kHz using a test setup including a modulated laser beam probed with a high-speed camera. The prototype showed stable behaviour during a one-hour-long operation at a maximum frequency of 5 kHz and with negligible heat generation. The maximum modulation amplitude was 60 arcsec. We observed very accurate reproduction of the input modulation pattern with typical ellipticities less than 1% and random deviations below 0.2% for frequencies below 4.5kHz. These tests demonstrate the prototype's capabilities and could be followed by on-sky tests or the integration of the modulator into XAO testbeds.

astro-ph.IM

Development of the Warm Astrometric Mask for MICADO astrometry calibration

The achievement of $μ$arcsec relative astrometry with ground-based, near infrared, extremely large telescopes requires a significant endeavour of calibration strategies. In this paper we address the removal of instrument optical distortions coming from the ELT first light instrument MICADO and its adaptive optics system MAORY by means of an astrometric calibration mask. The results of the test campaign on a prototype mask (scale 1:2) has probed the manufacturing precision down to $\sim$ 50nm/1mm scale, leading to a relative precision $δσ\sim 5e-5$. The assessed manufacturing precision indicates that an astrometric relative precision of $δσ\sim 5e-5 = \frac{50μas}{1 arcsec}$ is in principle achievable, disclosing $μ$arcsec near infrared astrometry behind an extremely large telescope. The impact of $\sim$ 10-100 nm error residuals on the mask pinholes position is tolerable at a calibration level as confirmed by ray tracing simulations of realistic MICADO distortion patterns affected by mid spatial frequencies residuals. We demonstrated that the MICADO astrometric precision of 50 $μ$as is achievable also in presence of a mid spatial frequencies pattern and manufacturing errors of the WAM by fitting the distorted WAM pattern seen through the instrument with a 10$^{th}$ order Legendre polynomial.

astro-ph.IM

The GRAVITY Coudé Infrared Adaptive Optics (CIAO) system for the VLT Interferometer

GRAVITY is a second generation instrument for the VLT Interferometer, designed to enhance the near-infrared astrometric and spectro-imaging capabilities of VLTI. Combining beams from four telescopes, GRAVITY will provide an astrometric precision of order 10 micro-arcseconds, imaging resolution of 4 milli-arcseconds, and low and medium resolution spectro-interferometry, pushing its performance far beyond current infrared interfero- metric capabilities. To maximise the performance of GRAVITY, adaptive optics correction will be implemented at each of the VLT Unit Telescopes to correct for the effects of atmospheric turbulence. To achieve this, the GRAVITY project includes a development programme for four new wavefront sensors (WFS) and NIR-optimized real time control system. These devices will enable closed-loop adaptive correction at the four Unit Telescopes in the range 1.4-2.4 μm. This is crucially important for an efficient adaptive optics implementation in regions where optically bright references sources are scarce, such as the Galactic Centre. We present here the design of the GRAVITY wavefront sensors and give an overview of the expected adaptive optics performance under typical observing conditions. Benefiting from newly developed SELEX/ESO SAPHIRA electron avalanche photodiode (eAPD) detectors providing fast readout with low noise in the near-infrared, the AO systems are expected to achieve residual wavefront errors of \leq400 nm at an operating frequency of 500 Hz.

astro-ph.IM

Near-infrared wavefront sensing for the VLT interferometer

The very large telescope (VLT) interferometer (VLTI) in its current operating state is equipped with high-order adaptive optics (MACAO) working in the visible spectrum. A low-order near-infrared wavefront sensor (IRIS) is available to measure non-common path tilt aberrations downstream the high-order deformable mirror. For the next generation of VLTI instrumentation, in particular for the designated GRAVITY instrument, we have examined various designs of a four channel high-order near-infrared wavefront sensor. Particular objectives of our study were the specification of the near-infrared detector in combination with a standard wavefront sensing system. In this paper we present the preliminary design of a Shack-Hartmann wavefront sensor operating in the near-infrared wavelength range, which is capable of measuring the wavefronts of four telescopes simultaneously. We further present results of our design study, which aimed at providing a first instrumental concept for GRAVITY.

astro-ph