Searcharxiv⌕ Search

arXiv subjects

Vicente González

Publications and source records attributed to Vicente González.

5 recordsLinked to original sources

Direct proton transfer on $^{46}$Ar supports the presence of a charge density bubble linked to a novel nuclear structure below $^{48}$Ca

The $^{46}$Ar($^3$He,d)$^{47}$K reaction was performed in inverse kinematics using a radioactive $^{46}$Ar beam produced by the SPIRAL1 facility at GANIL and a cryogenic $^{3}$He target. The AGATA-MUGAST-VAMOS setup allowed the coincident measurement of the $γ$ rays, deuterons and recoiling $^{47}$K isotopes produced by the reaction. The relative cross sections towards the proton-addition states in $^{47}$K point towards a depletion of the $πs_{1/2}$ shell. The experimental findings are in good agreement with ab initio calculations, which predict that $^{46}$Ar exhibits a charge density bubble associated with a pronounced proton closed-shell character.

nucl-ex↗

Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor

MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of $\sim150\,\mathrm{e^-}$. A precise knowledge of the threshold is crucial to understanding the charge collection in the pixel and specifying the environment for sensor application. A simple procedure is developed to calibrate the threshold to unit electrons making use of a dedicated charge injection circuit and an Fe-55 source with dominant charge deposition of $1600\, \mathrm{e^-}$. The injection voltage is determined which corresponds to the injection under Fe-55 exposure and is the basis for charge calibration. The charge injection circuit incorporates a capacitance with design value of $\mathrm{C_{inj}}=$ 230 aF. Experimentally, the average capacitance value for non-irradiated samples is found to be $\mathrm{C_{inj,exp}}=$ 257 aF. The 12 % divergence motivates the need for the presented precise calibration procedure, which is proposed to be performed for each MALTA2 sensor.

physics.ins-det↗

Radiation Hardness of MALTA2 Monolithic CMOS Sensors on Czochralski Substrates

MALTA2 is the latest full-scale prototype of the MALTA family of Depleted Monolithic Active Pixel Sensors (DMAPS) produced in Tower Semiconductor 180 nm CMOS technology. In order to comply with the requirements of High Energy Physics (HEP) experiments, various process modifications and front-end changes have been implemented to achieve low power consumption, reduce Random Telegraph Signal (RTS) noise, and optimise the charge collection geometry. Compared to its predecessors, MALTA2 targets the use of a high-resistivity, thick Czochralski (Cz) substrates in order to demonstrate radiation hardness in terms of detection efficiency and timing resolution up to 3E15 1 MeV neq/cm2 with backside metallisation to achieve good propagation of the bias voltage. This manuscript shows the results that were obtained with non-irradiated and irradiated MALTA2 samples on Cz substrates from the CERN SPS test beam campaign from 2021-2023 using the MALTA telescope.

physics.ins-det↗

Recent results with radiation-tolerant TowerJazz 180 nm MALTA Sensors

To achieve the physics goals of future colliders, it is necessary to develop novel, radiation-hard silicon sensors for their tracking detectors. We target the replacement of hybrid pixel detectors with Depleted Monolithic Active Pixel Sensors (DMAPS) that are radiation-hard, monolithic CMOS sensors. We have designed, manufactured and tested the MALTA series of sensors, which are DMAPS in the 180 nm TowerJazz CMOS imaging technology. MALTA have a pixel pitch well below current hybrid pixel detectors, high time resolution (< 2 ns) and excellent charge collection efficiency across pixel geometries. These sensors have a total silicon thickness of between 50-300 $μ$m, implying reduced material budgets and multiple scattering rates for future detectors which utilize such technology. Furthermore, their monolithic design bypasses the costly stage of bump-bonding in hybrid sensors and can substantially reduce detector costs. This contribution presents the latest results from characterization studies of the MALTA2 sensors, including results demonstrating the radiation tolerance of these sensors.

physics.ins-det↗

Quicker reaction, lower variability: The effect of transient time in flow variability of project-driven production

Based on the knowledge of dynamic systems, the shorter the transient response, or the faster a system reaches the steady-state after the introduction of the change, the smaller will be the output variability. In lean manufacturing, the principle of reducing set-up times has the same purpose: reduce the transient time and improve production flow. Analogously, the analysis of the transient response of project-driven systems may provide crucial information about how fast these systems react to a change and how that change affects their production output. Although some studies have investigated flow variability in projects, few have looked at variability from the perspective that the transient state represents the changeovers on project-driven production systems and how the transient state affects the process' flow variability. The purpose of this study is to investigate the effect of changes in project-driven production systems from a conceptual point of view, furthermore, measuring and correlating the transient response of five cases to their flow variability. Results showed a proportional relationship between the percentile transient time and flow variability of a process. That means that the quicker the production system reacts to change; the less the distress in the production output, consequently, lower levels of flow variability. As practical implications, lean practices focusing on reducing set-up times (transient time) can have their effects measured on project-driven production flow.

eess.SY↗