SearcharxivSearch

arXiv subjects

Victor Merza

Publications and source records attributed to Victor Merza.

2 recordsLinked to original sources

Toward Ionization Cluster Size Measurements with a Compact Nanodosimeter

Nanodosimetry aims to provide measurable quantities related to the nanoscopic particle track structure, which determines the biological effectiveness of radiation. While simulated nanodosimetry has already demonstrated its potential for radiation treatment planning, the experimental realization of practical nanodosimetric detectors is still in its early stages. In this work, a nanodosimetric prototype operated with low-pressure gas was developed to count ionizations in a nanometer-equivalent sensitive gas volume. Its performance was evaluated experimentally with alpha beams from an Am-241 source in 1 mbar propane gas. The results support the further development of this compact nanodosimeter class, with potential applications in particle therapy, radiation protection, and space radiation dosimetry.

physics.ins-det

Experimental and Monte Carlo Simulation Studies to Investigate the Working Principle of Compact Nanodosimeters

In recent years, compact nanodosimetric detectors based on ion multiplication in low-pressure gas have been developed and gained attention in the scientific community. These detectors use strong electric fields to collect and multiply positive ions produced by the incident radiation in mm-sized cell holes in dielectric materials, achieving a nm-equivalent spatial resolution of the localization of ionization events, when scaled to liquid water at unit density. Their design assumes that ion-impact ionizations of gas molecules within the cell holes dominate signal formation, yet this assumption has lacked direct physical verification. Electron emission from the cell hole walls or the cathode due to ion-impact could also contribute, requiring alternative designs to optimize efficiency. To investigate the relative importance of the possible mechanisms, a nanodosimetric detector featuring a single cell hole with a diameter of 1.5 mm in a dielectric plate was developed. Ion collection and multiplication were achieved by applying a negative high voltage to the glass cathode 0.5 mm below the cell hole, assisted by a low drift field above the plate. A grounded readout electrode with a 0.8 mm hole covers the cell hole to prevent interactions of collected ions with the hole walls. High signal yields in 1 mbar and 2 mbar propane gas were observed and indicated that ion-impact ionizations of the gas molecules could indeed be the primary mechanism for signal induction. Ion-induced secondary electron emission from the cathode was identified as another potential contribution. The compact nanodosimeter setup was further modeled with Geant4-DNA and Garfield++ for deeper insight. The results of these studies are important for understanding and developing a new class of nanodosimeters with potential applications in particle therapy, radiation protection, space dosimetry, and particle physics.

physics.ins-det