SearcharxivSearch

arXiv subjects

Vignesh Murugesan

Publications and source records attributed to Vignesh Murugesan.

17 recordsLinked to original sources

Demonstrating Single Photon Counting with Kinetic Inductance Detectors from 3.8 to 25 $\mu$m

One of the primary objectives of modern astronomy is the atmospheric characterization of Earth-like exoplanets at visible and infrared wavelengths. Achieving this goal requires extremely sensitive detectors capable of measuring faint signal of the exoplanet at the single-photon level while maintaining near-zero dark count rates. In the infrared, however, conventional semiconducting detector technologies struggle to meet these stringent requirements. In this work we demonstrate single-photon counting with superconducting Microwave Kinetic Inductance Detectors at the wavelengths 3.8, 8.5, 18.5, and 25 $\mu$m and measure resolving powers ($E/\delta E$) of 9.9, 5.9, 3.2, and 3.3, respectively, with corresponding dark count rates of 4, 8, 34, and 48 mHz. Our membrane-based devices reach phonon-loss limited performance at 3.8 $\mu$m, more than doubling the performance attainable with comparable solid-substrate devices. These results showcase the detector technology in the mid-infrared and the intricate measurement setup required for these sensitive detectors. We discuss how the detector design and measurement setup can be further optimized to increase the detector performance in the mid-infrared.

astro-ph.IM

Volume dependence of microwave induced excess quasiparticles in superconducting resonators

The presence of quasiparticles typically degrades the performance of superconducting microwave circuits. The readout signal can generate non-equilibrium quasiparticles, which lead to excess microwave loss and decoherence. To understand this effect quantitatively, we measure quasiparticle fluctuations and extract the quasiparticle density across different temperatures, readout powers, and resonator volumes. We find that microwave power generates a higher quasiparticle density as the active resonator volume is reduced and show that this effect sets a sensitivity limit on kinetic inductance detectors. We compare our results with theoretical models of direct microwave photon absorption by quasiparticles and conclude that an unknown, indirect mechanism plays a dominant role in quasiparticle generation. These results provide a route to mitigate quasiparticle generation due to readout power in superconducting devices.

cond-mat.supr-con

Demonstration of Ultra-Sensitive KIDs for Future THz Space Borne Polarimeters

We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. We find the integrated cross-polarization level to be at -21.5 dB for 1 f\#$\lambda$ spatial sampling. The measurements agree well with the theoretical description which is based on a combination of in-transmission simulation of the antenna feed, and an in-reception analysis of the antenna-KID system. Combined with the measured noise equivalent power of 5--7$\times$10$^{-20}$ W/$\sqrt{\mathrm{Hz}}$, these detectors are excellent candidates for large scale and high performance imaging polarimetric instruments.

astro-ph.IM

Recombination of localized quasiparticles in disordered superconductors

Disordered superconductors offer new impedance regimes for quantum circuits, enable a pathway to protected qubits, and can improve superconducting detectors due to their high kinetic inductance and sheet resistance. The performance of these devices can be limited, however, by quasiparticles - the fundamental excitations of a superconductor. While experiments have shown that disorder affects the relaxation of quasiparticles drastically, the microscopic mechanisms are still not understood. We address this issue by measuring quasiparticle relaxation in a disordered $\beta$-Ta film, which we pattern as the inductor of a microwave resonator. We observe that quasiparticle recombination is governed by the phonon scattering time, which is faster than conventional recombination in ordered superconductors. We interpret the results as recombination of localized quasiparticles, induced by disorder, which first delocalize via phonon absorption. We analyze quasiparticle relaxation measurements on superconductors with different degrees of disorder and conclude that this phenomenon is inherent to disordered superconductors.

cond-mat.supr-con

Resolving Power of Visible to Near-Infrared Hybrid $β$-Ta/NbTiN Kinetic Inductance Detectors

Kinetic Inductance Detectors (KIDs) are superconducting energy-resolving detectors, sensitive to single photons from the near-infrared to ultraviolet. We study a hybrid KID design consisting of a beta phase tantalum ($β$-Ta) inductor and a NbTiN interdigitated capacitor (IDC). The devices show an average intrinsic quality factor $Q_i$ of 4.3$\times10^5$ $\pm$ 1.3 $\times10^5$. To increase the power captured by the light sensitive inductor, we 3D-print an array of 150$\times$150 $μ$m resin micro lenses on the backside of the sapphire substrate. The shape deviation between design and printed lenses is smaller than 1$μ$m, and the alignment accuracy of this process is $δ_x = +5.8 \pm 0.5$ $μ$m and $δ_y = +8.3 \pm 3.3$ $μ$m. We measure a resolving power for 1545-402 nm that is limited to 4.9 by saturation in the KID's phase response. We can model the saturation in the phase response with the evolution of the number of quasiparticles generated by a photon event. An alternative coordinate system that has a linear response raises the resolving power to 5.9 at 402 nm. We verify the measured resolving power with a two-line measurement using a laser source and a monochromator. We discuss several improvements that can be made to the devices on a route towards KID arrays with high resolving powers.

physics.ins-det

DESHIMA 2.0: development of an integrated superconducting spectrometer for science-grade astronomical observations

Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed to observe the 220-440 GHz band in a single shot, corresponding to a redshift range of $z$=3.3-7.6 for the ionized carbon emission ([C II] 158 $μ$m). The first-light experiment of DESHIMA 1.0, using the 332-377 GHz band, has shown an excellent agreement among the on-sky measurements, the lab measurements, and the design. As a successor to DESHIMA 1.0, we plan the commissioning and the scientific observation campaign of DESHIMA 2.0 on the ASTE 10-m telescope in 2023. Ongoing upgrades for the full octave-bandwidth system include the wideband 347-channel chip design and the wideband quasi-optical system. For efficient measurements, we also develop the observation strategy using the mechanical fast sky-position chopper and the sky-noise removal technique based on a novel data-scientific approach. In the paper, we show the recent status of the upgrades and the plans for the scientific observation campaign.

astro-ph.IM

Strong Reduction of Quasiparticle Fluctuations in a Superconductor due to Decoupling of the Quasiparticle Number and Lifetime

We measure temperature dependent quasiparticle fluctuations in a small Al volume, embedded in a NbTiN superconducting microwave resonator. The resonator design allows for read-out close to equilibrium. By placing the Al film on a membrane, we enhance the fluctuation level and separate quasiparticle from phonon effects. When lowering the temperature, the recombination time saturates and the fluctuation level reduces a factor $\sim$100. From this we deduce that the number of free quasiparticles is still thermal. Therefore, the theoretical, inverse relation between quasiparticle number and recombination time is invalid in this experiment. This is consistent with quasiparticle trapping, where on-trap recombination limits the observed quasiparticle lifetime.

cond-mat.supr-con

Terahertz Band-Pass Filters for Wideband Superconducting On-chip Filter-bank Spectrometers

A superconducting microstrip half-wavelength resonator is proposed as a suitable band-pass filter for broadband moderate spectral resolution spectroscopy for terahertz (THz) astronomy. The proposed filter geometry has a free spectral range of an octave of bandwidth without introducing spurious resonances, reaches a high coupling efficiency in the pass-band and shows very high rejection in the stop-band to minimize reflections and cross-talk with other filters. A spectrally sparse prototype filter-bank in the band 300-400 GHz has been developed employing these filters as well as an equivalent circuit model to anticipate systematic errors. The fabricated chip has been characterized in terms of frequency response, reporting an average peak coupling efficiency of 27% with an average spectral resolution of 940.

astro-ph.IM

Phonon-trapping enhanced energy resolution in superconducting single photon detectors

A noiseless, photon counting detector, which resolves the energy of each photon, could radically change astronomy, biophysics and quantum optics. Superconducting detectors promise an intrinsic resolving power at visible wavelengths of $R=E/δE\approx100$ due to their low excitation energy. We study superconducting energy-resolving Microwave Kinetic Inductance Detectors (MKIDs), which hold particular promise for larger cameras. A visible/near-infrared photon absorbed in the superconductor creates a few thousand quasiparticles through several stages of electron-phonon interaction. Here we demonstrate experimentally that the resolving power of MKIDs at visible to near-infrared wavelengths is limited by the loss of hot phonons during this process. We measure the resolving power of our aluminum-based detector as a function of photon energy using four lasers with wavelengths between $1545-402$ nm. For detectors on thick SiN/Si and sapphire substrates the resolving power is limited to $10-21$ for the respective wavelengths, consistent with the loss of hot phonons. When we suspend the sensitive part of the detector on a 110 nm thick SiN membrane, the measured resolving power improves to $19-52$ respectively. The improvement is equivalent to a factor $8\pm2$ stronger phonon trapping on the membrane, which is consistent with a geometrical phonon propagation model for these hot phonons. We discuss a route towards the Fano limit by phonon engineering.

astro-ph.IM

Characterization of low-loss hydrogenated amorphous silicon films for superconducting resonators

Superconducting resonators used in millimeter-submillimeter astronomy would greatly benefit from deposited dielectrics with a small dielectric loss. We deposited hydrogenated amorphous silicon films using plasma-enhanced chemical vapor deposition, at substrate temperatures of 100°C, 250°C and 350°C. The measured void volume fraction, hydrogen content, microstructure parameter, and bond-angle disorder are negatively correlated with the substrate temperature. All three films have a loss tangent below $10^{-5}$ for a resonator energy of $10^5$ photons, at 120 mK and 4-7 GHz. This makes these films promising for microwave kinetic inductance detectors and on-chip millimeter-submilimeter filters.

astro-ph.IM

Simulating the radiation loss of superconducting submillimeter wave filters and transmission lines using Sonnet EM

Superconducting resonators and transmission lines are fundamental building blocks of integrated circuits for millimeter-submillimeter astronomy. Accurate simulation of radiation loss from the circuit is crucial for the design of these circuits because radiation loss increases with frequency, and can thereby deteriorate the system performance. Here we show a stratification for a 2.5-dimensional method-of-moment simulator Sonnet EM that enables accurate simulations of the radiative resonant behavior of submillimeter-wave coplanar resonators and straight coplanar waveguides (CPWs). The Sonnet simulation agrees well with the measurement of the transmission through a coplanar resonant filter at 374.6 GHz. Our Sonnet stratification utilizes artificial lossy layers below the lossless substrate to absorb the radiation, and we use co-calibrated internal ports for de-embedding. With this type of stratification, Sonnet can be used to model superconducting millimeter-submillimeter wave circuits even when radiation loss is a potential concern.

astro-ph.IM

DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer

We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.

astro-ph.IM

An Ultra-Wideband Leaky Lens Antenna for Broadband Spectroscopic Imaging Applications

We present the design, fabrication and characterisation of a broadband leaky lens antenna for broadband, spectroscopic imaging applications. The antenna is designed for operation in the 300-900 GHz band. We integrate the antenna directly into an Al-NbTiN hybrid MKID to measure the beam pattern and absolute coupling efficiency at three frequency bands centred around 350, 650 and 850 GHz, covering the full antenna band. We find an aperture efficiency $η_{ap} \approx 0.4$ over the whole frequency band, limited by lens reflections. We find a good match with simulations for both the patterns and efficiency, demonstrating a 1:3 bandwidth in the sub-mm wavelength range for future on-chip spectrometers.

physics.ins-det

First light demonstration of the integrated superconducting spectrometer

Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pixels (>$10^2$). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of $F/ΔF \sim 380$. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$ allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.

astro-ph.IM

Wideband on-chip terahertz spectrometer based on a superconducting filterbank

Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinetic inductance detector behind each filter. Using frequency division multiplexing, all detectors are read-out simultaneously creating a wide-band spectrometer with an instantaneous bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral resolution of $F/ΔF=380$ and reaches photon-noise limited sensitivity. We discuss the chip design and fabrication, as well as the system integration and testing. We confirm full system operation by the detection of an emission line spectrum of methanol gas. The proposed concept allows for spectroscopic radiation detection over large bandwidths and resolutions up to $F/ΔF\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the construction of medium resolution imaging spectrometers with unprecedented speed and sensitivity.

astro-ph.IM

Eliminating stray radiation inside large area imaging arrays

With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves. We demonstrate this effect with focal plane arrays of absorber coupled Lumped Element microwave Kinetic Inductance Detectors (LEKIDs) and lens-antenna coupled distributed quarter wavelength Microwave Kinetic Inductance Detectors (MKIDs). In these arrays the response from a point source at the pixel position is at a similar level to the stray response integrated over the entire chip area. For the antenna coupled arrays, we show that this effect can be suppressed by incorporating an on-chip stray light absorber. A similar method should be possible with the LEKID array, especially when they are lens coupled.

astro-ph.IM

Surface wave control for large arrays of microwave kinetic inductance detectors

Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray radiation inside the detector chips themselves, the surface wave. We demonstrate this effect with focal plane arrays of 880 lens-antenna coupled Microwave Kinetic Inductance Detectors (MKIDs). Presented here are near field measurements of the MKID optical response versus the position on the array of a reimaged optical source. We demonstrate that the optical response of a detector in these arrays saturates off-pixel at the $\sim-30$ dB level compared to the peak pixel response. The result is that the power detected from a point source at the pixel position is almost identical to the stray response integrated over the chip area. With such a contribution, it would be impossible to measure extended sources, while the point source sensitivity is degraded due to an increase of the stray loading. However, we show that by incorporating an on-chip stray light absorber, the surface wave contribution is reduced by a factor $>$10. With the on-chip stray light absorber the point source response is close to simulations down to the $\sim-35$ dB level, the simulation based on an ideal Gaussian illumination of the optics. In addition, as a crosscheck we show that the extended source response of a single pixel in the array with the absorbing grid is in agreement with the integral of the point source measurements.

astro-ph.IM