Searcharxiv⌕ Search

arXiv subjects

Vijay K. Dubey

Publications and source records attributed to Vijay K. Dubey.

3 recordsLinked to original sources

Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

cs.CE↗

Fully Differentiable Ultrasound Simulation Utilizing Ray-Tracing

Ultrasound imaging tasks such as calibration, inverse parameter estimation, and acquisition design require models that are physically grounded, efficient, and differentiable with respect to meaningful material and system parameters. While full-wave solvers offer high fidelity, they are often too expensive for iterative optimization, and existing ray-based methods have mostly been limited to forward simulation. In this work, we present a fully differentiable end-to-end ultrasound simulation framework based on full-path Monte Carlo ray tracing. Building on UltraRay, the method propagates gradients from image-space losses back through acoustic transport, beamforming, and post-processing, enabling gradient-based optimization over scene and acquisition parameters. The framework combines differentiable ray transport in Mitsuba 3/Dr.Jit with a custom differentiable bridge through the ultrasound image-formation pipeline. Forward examples reproduce expected geometric image features and capture more complex anatomical structures. In inverse problems, the method recovers known parameters in a simulated-reference setting and identifies effective parameters that improve agreement between simulated and experimental B-mode images in a simulation-to-real setting. Finite-difference comparisons further support the consistency of the computed gradients. Overall, this work provides a practical foundation for differentiable, physics-based ultrasound simulation and optimization.

cs.CE↗

Graph Neural Network Surrogates for Contacting Deformable Bodies with Necessary and Sufficient Contact Detection

Surrogate models for the rapid inference of nonlinear boundary value problems in mechanics are helpful in a broad range of engineering applications. However, effective surrogate modeling of applications involving the contact of deformable bodies, especially in the context of varying geometries, is still an open issue. In particular, existing methods are confined to rigid body contact or, at best, contact between rigid and soft objects with well-defined contact planes. Furthermore, they employ contact or collision detection filters that serve as a rapid test but use only the necessary and not sufficient conditions for detection. In this work, we present a graph neural network architecture that utilizes continuous collision detection and, for the first time, incorporates sufficient conditions designed for contact between soft deformable bodies. We test its performance on two benchmarks, including a problem in soft tissue mechanics of predicting the closed state of a bioprosthetic aortic valve. We find a regularizing effect on adding additional contact terms to the loss function, leading to better generalization of the network. These benefits hold for simple contact at similar planes and element normal angles, and complex contact at differing planes and element normal angles. We also demonstrate that the framework can handle varying reference geometries. However, such benefits come with high computational costs during training, resulting in a trade-off that may not always be favorable. We quantify the training cost and the resulting inference speedups on various hardware architectures. Importantly, our graph neural network implementation results in up to a thousand-fold speedup for our benchmark problems at inference.

cs.CE↗