SearcharxivSearch

arXiv subjects

Vijay R. Sharma

Publications and source records attributed to Vijay R. Sharma.

2 recordsLinked to original sources

The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification

This study presents the first clinical integration and experimental demonstration of a nozzle-mounted Compton camera prompt gamma imaging (PGI) system for in vivo proton range verification. Four position-sensitive solid-state Compton camera modules, each containing four cadmium zinc telluride (CdZnTe) detector crystals, were integrated into a modified range shifter mounted directly on the treatment nozzle of a clinical proton therapy gantry. This compact fixed-geometry configuration maintained alignment with the proton beam axis throughout irradiation and enabled stable synchronized data acquisition during pencil-beam scanning delivery. The system was evaluated under realistic clinical proton beam delivery conditions using single-energy and spread-out Bragg peak (SOBP) irradiations at gantry angles of 90° and 270°, delivered doses of 2 Gy and 7.5 Gy, and controlled distal range shifts of up to 10 mm. Prompt gamma events were reconstructed into three-dimensional emission distributions using a physics-based Compton scatter reconstruction framework. The system operated reliably during all irradiations and produced reproducible prompt-gamma localization across repeated measurements. Reconstructed emission distributions remained geometrically consistent across gantry angles and demonstrated sensitivity to controlled distal range perturbations, with measurable upstream shifts of the emission hotspot corresponding to reduced proton penetration depth. These results demonstrate the feasibility of a clinically integrated nozzle-mounted quad-camera Compton PGI system for detecting millimeter-scale proton range variations during beam delivery and represent an important step toward clinically deployable prompt gamma-based in vivo treatment verification in proton therapy.

physics.med-ph

Response of G-NUMEN LaBr$_3$(Ce) detectors to high counting rates

The G-NUMEN array is the future gamma spectrometer of the NUMEN experiment (Nuclear Matrix Element for the Neutrinoless double beta decay), to be installed around the object point of the MAGNEX magnetic spectrometer at the INFN-LNS laboratory. This project aims at exploring Double Charge Exchange (DCE) reactions in order to obtain crucial information about the neutrinoless double beta decay ($0νββ$). The primary objective of the G-NUMEN array is to detect the gamma rays emitted from the deexcitation of the excited states populated via DCE reactions with good energy resolution and detection efficiency, amidst a background composed of transitions from competing reaction channels with far higher cross sections. To achieve this, the G-NUMEN signals will be processed in coincidence with those generated by the detection of the reaction ejectiles in the MAGNEX Focal Plane Detector(FPD). Under the expected experimental conditions, G-NUMEN detectors will operate at high counting rates, of the order of hundreds of kHz per detector, while maintaining excellent energy and timing resolutions. The complete array will consist of over 100 LaBr$_3$(Ce) scintillators. Initial tests have been conducted on the first detectors of the array, allowing for the determination of their performance at high rates.

physics.ins-det