SearcharxivSearch

arXiv subjects

Viktor Vegh

Publications and source records attributed to Viktor Vegh.

15 recordsLinked to original sources

Weakly Supervised Pathology-Informed Representation Learning for PET-Based Content Retrieval of Intra-Tumour Heterogeneity

We propose a weakly supervised 18FFDG PET representation-learning framework for content based medical image retrieval, using H&E derived information during training while preserving PET-only inference. The proposed method was designed to use H&E derived information during training while maintaining PET only inference. A teacher student training strategy was used to learn the PET tumour derived voxel representations, from which global and hotspot conditioned embeddings were generated along with maps of intra tumour heterogeneity in our oesophegeal cancer test case. A progressive ablation strategy was used to evaluate the contribution of different supervision mechanisms. Retrieval performance was assessed across cross-validation folds using metrics including mean average precision, normalised discounted cumulative gain and mean reciprocal rank. Additional analyses evaluated ablation performance, hotspot faithfulness through perturbation/deletion experiments, prototype-specific PET uptake behaviour and indirect patient level concordance between learned PET prototype classes and selected histomic features. Progressive introduction of pathology informed supervision and hotspot modelling improved PET retrieval performance compared with global PET representations and conventional PET baselines. Across the ablation ladder, PET hotspot conditioned representations consistently provided stronger retrieval than global embeddings, indicating that focusing on informative tumour subregions improved sensitivity to intra tumour heterogeneity. Histopathology concordance further showed that the learned classes were not simply high uptake PET regions; instead, they demonstrated distinct heterogeneity in 18F FDG uptake.

cs.CV

Stress-testing cross-cancer generalizability of 3D nnU-Net for PET-CT tumor segmentation: multi-cohort evaluation with novel oesophageal and lung cancer datasets

Robust generalization is essential for deploying deep learning based tumor segmentation in clinical PET-CT workflows, where anatomical sites, scanners, and patient populations vary widely. This study presents the first cross cancer evaluation of nnU-Net on PET-CT, introducing two novel, expert-annotated whole-body datasets. 279 patients with oesophageal cancer (Australian cohort) and 54 with lung cancer (Indian cohort). These cohorts complement the public AutoPET dataset and enable systematic stress-testing of cross domain performance. We trained and tested 3D nnUNet models under three paradigms. Target only (oesophageal), public only (AutoPET), and combined training. For the tested sets, the oesophageal only model achieved the best in-domain accuracy (mean DSC, 57.8) but failed on external Indian lung cohort (mean DSC less than 3.4), indicating severe overfitting. The public only model generalized more broadly (mean DSC, 63.5 on AutoPET, 51.6 on Indian lung cohort) but underperformed in oesophageal Australian cohort (mean DSC, 26.7). The combined approach provided the most balanced results (mean DSC, lung (52.9), oesophageal (40.7), AutoPET (60.9)), reducing boundary errors and improving robustness across all cohorts. These findings demonstrate that dataset diversity, particularly multi demographic, multi center and multi cancer integration, outweighs architectural novelty as the key driver of robust generalization. This work presents the demography based cross cancer deep learning segmentation evaluation and highlights dataset diversity, rather than model complexity, as the foundation for clinically robust segmentation.

eess.IV

The potential role of AI agents in transforming nuclear medicine research and cancer management in India

India faces a significant cancer burden, with an incidence-to-mortality ratio indicating that nearly three out of five individuals diagnosed with cancer succumb to the disease. While the limitations of physical healthcare infrastructure are widely acknowledged as a primary challenge, concerted efforts by government and healthcare agencies are underway to mitigate these constraints. However, given the country's vast geography and high population density, it is imperative to explore alternative soft infrastructure solutions to complement existing frameworks. Artificial Intelligence agents are increasingly transforming problem-solving approaches across various domains, with their application in medicine proving particularly transformative. In this perspective, we examine the potential role of AI agents in advancing nuclear medicine for cancer research, diagnosis, and management in India. We begin with a brief overview of AI agents and their capabilities, followed by a proposed agent-based ecosystem that can address prevailing sustainability challenges in India nuclear medicine.

cs.MA

Robust, fast and accurate mapping of diffusional mean kurtosis

Diffusional kurtosis imaging (DKI) is a methodology for measuring the extent of non-Gaussian diffusion in biological tissue, which has shown great promise in clinical diagnosis, treatment planning and monitoring of many neurological diseases and disorders. However, robust, fast and accurate estimation of kurtosis from clinically feasible data acquisitions remains a challenge. In this study, we first outline a new accurate approach of estimating mean kurtosis via the sub-diffusion mathematical framework. Crucially, this extension of the conventional DKI overcomes the limitation on the maximum b-value of the latter. Kurtosis and diffusivity can now be simply computed as functions of the sub-diffusion model parameters. Second, we propose a new fast and robust fitting procedure to estimate the sub-diffusion model parameters using two diffusion times without increasing acquisition time as for the conventional DKI. Third, our sub-diffusion based kurtosis mapping method is evaluated using both simulations and the Connectome 1.0 human brain data. Exquisite tissue contrast is achieved even when the diffusion encoded data is collected in only minutes. In summary, our findings suggest robust, fast and accurate estimation of mean kurtosis can be realised within a clinically feasible diffusion weighted magnetic resonance imaging data acquisition time.

eess.IV

NeuroMorphix: A Novel Brain MRI Asymmetry-specific Feature Construction Approach For Seizure Recurrence Prediction

Seizure recurrence is an important concern after an initial unprovoked seizure; without drug treatment, it occurs within 2 years in 40-50% of cases. The decision to treat currently relies on predictors of seizure recurrence risk that are inaccurate, resulting in unnecessary, possibly harmful, treatment in some patients and potentially preventable seizures in others. Because of the link between brain lesions and seizure recurrence, we developed a recurrence prediction tool using machine learning and clinical 3T brain MRI. We developed NeuroMorphix, a feature construction approach based on MRI brain anatomy. Each of seven NeuroMorphix features measures the absolute or relative difference between corresponding regions in each cerebral hemisphere. FreeSurfer was used to segment brain regions and to generate values for morphometric parameters (8 for each cortical region and 5 for each subcortical region). The parameters were then mapped to whole brain NeuroMorphix features, yielding a total of 91 features per subject. Features were generated for a first seizure patient cohort (n = 169) categorised into seizure recurrence and non-recurrence subgroups. State-of-the-art classification algorithms were trained and tested using NeuroMorphix features to predict seizure recurrence. Classification models using the top 5 features, ranked by sequential forward selection, demonstrated excellent performance in predicting seizure recurrence, with area under the ROC curve of 88-93%, accuracy of 83-89%, and F1 score of 83-90%. Highly ranked features aligned with structural alterations known to be associated with epilepsy. This study highlights the potential for targeted, data-driven approaches to aid clinical decision-making in brain disorders.

eess.IV

Machine Learning Applications in Traumatic Brain Injury: A Spotlight on Mild TBI

Traumatic Brain Injury (TBI) poses a significant global public health challenge, contributing to high morbidity and mortality rates and placing a substantial economic burden on healthcare systems worldwide. The diagnosis of TBI relies on clinical information along with Computed Tomography (CT) scans. Addressing the multifaceted challenges posed by TBI has seen the development of innovative, data-driven approaches, for this complex condition. Particularly noteworthy is the prevalence of mild TBI (mTBI), which constitutes the majority of TBI cases where conventional methods often fall short. As such, we review the state-of-the-art Machine Learning (ML) techniques applied to clinical information and CT scans in TBI, with a particular focus on mTBI. We categorize ML applications based on their data sources, and there is a spectrum of ML techniques used to date. Most of these techniques have primarily focused on diagnosis, with relatively few attempts at predicting the prognosis. This review may serve as a source of inspiration for future research studies aimed at improving the diagnosis of TBI using data-driven approaches and standard diagnostic data.

eess.IV

Enhancing mTBI Diagnosis with Residual Triplet Convolutional Neural Network Using 3D CT

Mild Traumatic Brain Injury (mTBI) is a common and challenging condition to diagnose accurately. Timely and precise diagnosis is essential for effective treatment and improved patient outcomes. Traditional diagnostic methods for mTBI often have limitations in terms of accuracy and sensitivity. In this study, we introduce an innovative approach to enhance mTBI diagnosis using 3D Computed Tomography (CT) images and a metric learning technique trained with triplet loss. To address these challenges, we propose a Residual Triplet Convolutional Neural Network (RTCNN) model to distinguish between mTBI cases and healthy ones by embedding 3D CT scans into a feature space. The triplet loss function maximizes the margin between similar and dissimilar image pairs, optimizing feature representations. This facilitates better context placement of individual cases, aids informed decision-making, and has the potential to improve patient outcomes. Our RTCNN model shows promising performance in mTBI diagnosis, achieving an average accuracy of 94.3%, a sensitivity of 94.1%, and a specificity of 95.2%, as confirmed through a five-fold cross-validation. Importantly, when compared to the conventional Residual Convolutional Neural Network (RCNN) model, the RTCNN exhibits a significant improvement, showcasing a remarkable 22.5% increase in specificity, a notable 16.2% boost in accuracy, and an 11.3% enhancement in sensitivity. Moreover, RTCNN requires lower memory resources, making it not only highly effective but also resource-efficient in minimizing false positives while maximizing its diagnostic accuracy in distinguishing normal CT scans from mTBI cases. The quantitative performance metrics provided and utilization of occlusion sensitivity maps to visually explain the model's decision-making process further enhance the interpretability and transparency of our approach.

eess.IV

Interpretable 3D Multi-Modal Residual Convolutional Neural Network for Mild Traumatic Brain Injury Diagnosis

Mild Traumatic Brain Injury (mTBI) is a significant public health challenge due to its high prevalence and potential for long-term health effects. Despite Computed Tomography (CT) being the standard diagnostic tool for mTBI, it often yields normal results in mTBI patients despite symptomatic evidence. This fact underscores the complexity of accurate diagnosis. In this study, we introduce an interpretable 3D Multi-Modal Residual Convolutional Neural Network (MRCNN) for mTBI diagnostic model enhanced with Occlusion Sensitivity Maps (OSM). Our MRCNN model exhibits promising performance in mTBI diagnosis, demonstrating an average accuracy of 82.4%, sensitivity of 82.6%, and specificity of 81.6%, as validated by a five-fold cross-validation process. Notably, in comparison to the CT-based Residual Convolutional Neural Network (RCNN) model, the MRCNN shows an improvement of 4.4% in specificity and 9.0% in accuracy. We show that the OSM offers superior data-driven insights into CT images compared to the Grad-CAM approach. These results highlight the efficacy of the proposed multi-modal model in enhancing the diagnostic precision of mTBI.

eess.IV

Instant tissue field and magnetic susceptibility mapping from MR raw phase using Laplacian enabled deep neural networks

Quantitative susceptibility mapping (QSM) is a valuable MRI post-processing technique that quantifies the magnetic susceptibility of body tissue from phase data. However, the traditional QSM reconstruction pipeline involves multiple non-trivial steps, including phase unwrapping, background field removal, and dipole inversion. These intermediate steps not only increase the reconstruction time but amplify noise and errors. This study develops a large-stencil Laplacian preprocessed deep learning-based neural network for near instant quantitative field and susceptibility mapping (i.e., iQFM and iQSM) from raw MR phase data. The proposed iQFM and iQSM methods were compared with established reconstruction pipelines on simulated and in vivo datasets. In addition, experiments on patients with intracranial hemorrhage and multiple sclerosis were also performed to test the generalization of the novel neural networks. The proposed iQFM and iQSM methods yielded comparable results to multi-step methods in healthy subjects while dramatically improving reconstruction accuracies on intracranial hemorrhages with large susceptibilities. The reconstruction time was also substantially shortened from minutes using multi-step methods to only 30 milliseconds using the trained iQFM and iQSM neural networks.

eess.IV

Generalisation of continuous time random walk to anomalous diffusion MRI models with an age-related evaluation of human corpus callosum

Diffusion MRI measures of the human brain provide key insight into microstructural variations across individuals and into the impact of central nervous system diseases and disorders. One approach to extract information from diffusion signals has been to use biologically relevant analytical models to link millimetre scale diffusion MRI measures with microscale influences. The other approach has been to represent diffusion as an anomalous transport process and infer microstructural information from the different anomalous diffusion equation parameters. In this study, we investigated how parameters of various anomalous diffusion models vary with age in the human brain white matter, particularly focusing on the corpus callosum. We first unified several established anomalous diffusion models (the super-diffusion, sub-diffusion, quasi-diffusion and fractional Bloch-Torrey models) under the continuous time random walk modelling framework. This unification allows a consistent parameter fitting strategy to be applied from which meaningful model parameter comparisons can be made. We then provided a novel way to derive the diffusional kurtosis imaging (DKI) model, which is shown to be a degree two approximation of the sub-diffusion model. This link between the DKI and sub-diffusion models led to a new robust technique for generating maps of kurtosis and diffusivity using the sub-diffusion parameters \b{eta}_SUB and D_SUB. Superior tissue contrast is achieved in kurtosis maps based on the sub-diffusion model. 7T diffusion weighted MRI data for 65 healthy participants in the age range 19-78 years was used in this study. Results revealed that anomalous diffusion model parameters α and \b{eta} have shown consistent positive correlation with age in the corpus callosum, indicating α and \b{eta} are sensitive to tissue microstructural changes in aging.

physics.med-ph

Fractional order magnetic resonance fingerprinting in the human cerebral cortex

Mathematical models are becoming increasingly important in magnetic resonance imaging (MRI), as they provide a mechanistic approach for making a link between tissue microstructure and signals acquired using the medical imaging instrument. The Bloch equations, which describes spin and relaxation in a magnetic field, is a set of integer order differential equations with a solution exhibiting mono-exponential behaviour in time. Parameters of the model may be estimated using a non-linear solver, or by creating a dictionary of model parameters from which MRI signals are simulated and then matched with experiment. We have previously shown the potential efficacy of a magnetic resonance fingerprinting (MRF) approach, i.e. dictionary matching based on the classical Bloch equations, for parcellating the human cerebral cortex. However, this classical model is unable to describe in full the mm-scale MRI signal generated based on an heterogenous and complex tissue micro-environment. The time-fractional order Bloch equations has been shown to provide, as a function of time, a good fit of brain MRI signals. We replaced the integer order Bloch equations with the previously reported time-fractional counterpart within the MRF framework and performed experiments to parcellate human gray matter, which is cortical brain tissue with different cyto-architecture at different spatial locations. Our findings suggest that the time-fractional order parameters, α and β, potentially associate with the effect of interareal architectonic variability, hypothetically leading to more accurate cortical parcellation.

physics.med-ph

CNNs and GANs in MRI-based cross-modality medical image estimation

Cross-modality image estimation involves the generation of images of one medical imaging modality from that of another modality. Convolutional neural networks (CNNs) have been shown to be useful in identifying, characterising and extracting image patterns. Generative adversarial networks (GANs) use CNNs as generators and estimated images are discriminated as true or false based on an additional network. CNNs and GANs within the image estimation framework may be considered more generally as deep learning approaches, since imaging data tends to be large, leading to a larger number of network weights. Almost all research in the CNN/GAN image estimation literature has involved the use of MRI data with the other modality primarily being PET or CT. This review provides an overview of the use of CNNs and GANs for MRI-based cross-modality medical image estimation. We outline the neural networks implemented, and detail network constructs employed for CNN and GAN image-to-image estimators. Motivations behind cross-modality image estimation are provided as well. GANs appear to provide better utility in cross-modality image estimation in comparison with CNNs, a finding drawn based on our analysis involving metrics comparing estimated and actual images. Our final remarks highlight key challenges faced by the cross-modality medical image estimation field, and suggestions for future research are outlined.

eess.IV

Improving FLAIR SAR efficiency at 7T by adaptive tailoring of adiabatic pulse power using deep convolutional neural networks

Purpose: The purpose of this study is to demonstrate a method for Specific Absorption Rate (SAR) reduction for T2-FLAIR MRI sequences at 7T by predicting the required adiabatic pulse power and scaling the amplitude in a slice-wise fashion. Methods: We used a TR-FOCI adiabatic pulse for spin inversion in a T2-FLAIR sequence to improve B1+ homogeneity and calculate the pulse power required for adiabaticity slice-by-slice to minimize the SAR. Drawing on the implicit B1+ inhomogeneity present in a standard localizer scan, 3D AutoAlign localizers and SA2RAGE B1+ maps were acquired in eight volunteers. A convolutional neural network (CNN) was then trained to predict the B1+ profile from the localizers and scale factors for the pulse power for each slice were calculated. The ability to predict the B1+ profile as well as how the derived pulse scale factors affected the FLAIR inversion efficiency were assessed in transverse, sagittal, and coronal orientations. Results: The predicted B1+ maps matched the measured B1+ maps with a mean difference of 4.45% across all slices. The acquisition in the transverse orientation was shown to be most effective for this method and delivered a 40% reduction in SAR along with 1min and 30-sec reduction in scan time (28%) without degradation of image quality. Conclusion: We propose a SAR reduction technique based on the prediction of B1+ profiles from standard localizer scans using a CNN and show that scaling the inversion pulse power slice-by-slice for FLAIR sequences at 7T reduces SAR and scan time without compromising image quality.

eess.IV

Probing entanglement in Compton interactions

This theoretical research aims to examine areas of the Compton cross section of entangled annihilation photons for the purpose of testing for possible break down of theory, which could have consequences for predicted optimal capabilities of Compton PET systems.We provide maps of the cross section for entangled annihilation photons for experimental verification.We introduce a strategy to derive cross sections in a relatively straight forward manner for the Compton scattering of a hypothetical separable, mixed and entangled states. To understand the effect that entanglement has on the cross section for annihilation photons, we derive the cross section so that it is expressed in terms of the cross section of a hypothetical separable state and of a hypothetical forbidden maximally entangled state.We find lobe-like structures in the cross section which are regions where entanglement has the greatest effect.We also find that mixed states do not reproduce the cross section for annihilation photons, contrary to a recent investigation which reported otherwise.We review the motivation and method of the most precise Compton scattering experiment for annihilation photons, in order to resolve conflicting reports regarding the extent to which the cross section itself has been experimentally verified.

physics.optics

Linear centralization classifier

A classification algorithm, called the Linear Centralization Classifier (LCC), is introduced. The algorithm seeks to find a transformation that best maps instances from the feature space to a space where they concentrate towards the center of their own classes, while maximimizing the distance between class centers. We formulate the classifier as a quadratic program with quadratic constraints. We then simplify this formulation to a linear program that can be solved effectively using a linear programming solver (e.g., simplex-dual). We extend the formulation for LCC to enable the use of kernel functions for non-linear classification applications. We compare our method with two standard classification methods (support vector machine and linear discriminant analysis) and four state-of-the-art classification methods when they are applied to eight standard classification datasets. Our experimental results show that LCC is able to classify instances more accurately (based on the area under the receiver operating characteristic) in comparison to other tested methods on the chosen datasets. We also report the results for LCC with a particular kernel to solve for synthetic non-linear classification problems.

cs.LG