SearcharxivSearch

arXiv subjects

Viktoria Hinger

Publications and source records attributed to Viktoria Hinger.

8 recordsLinked to original sources

Non-destructive 3D doping imaging of silicon sensors

Silicon sensors are the foundational detection medium for X-rays and charged particles. While their bulk dopant distribution determines device performance, it is conventionally assumed homogeneous because traditional profiling is destructive, spatially restricted, and insensitive at the relevant concentrations. Here we introduce a non-destructive 3D doping imaging technique that turns the readout electronics of a charge-integrating hybrid pixel detector into a massively parallelized capacitance-voltage profiler. With a few tens of micrometres of 3D resolution over wafer-scale areas at concentrations on the order of $10^{11}$ cm$^{-3}$, we image the bulk doping concentration of operational sensors. Macroscopically, we resolve depth-evolving concentric doping rings; microscopically, we uncover scattered doping anomalies that distort local electric fields. The rings modulate the depletion voltage, while the anomalies disrupt local charge collection, a previously overlooked cause of pixel yield and performance degradation. By bridging manufacturing signatures with microscopic defects, this approach provides a non-destructive framework for sensor characterization and yield optimization.

physics.ins-det

High frame rate RIXS spectroscopy using a JUNGFRAU detector with an iLGAD sensor

Resonant inelastic X-ray scattering (RIXS) is a powerful photon-in, photon-out spectroscopy technique for probing electronic, magnetic, and lattice excitations in matter. Time-resolved RIXS extends this capability through a stroboscopic optical pump-probe scheme to characterize the time evolution of the photoexcitation and subsequent relaxation dynamics of a sample. This technique is, however, extremely photon-hungry, requiring high-repetition-rate and intense X-ray facilities. The Heisenberg RIXS (hRIXS) spectrometer at the Spectroscopy and Coherent Scattering (SCS) instrument of the European X-ray Free-Electron Laser (EuXFEL) is designed to exploit high-repetition-rates, while maintaining optimal time and energy resolution. In this work, we demonstrate the successful deployment of a JUNGFRAU detector equipped with an inverse Low Gain Avalanche Diode (iLGAD) sensor for time-resolved RIXS studies in the soft X-ray range, using the hRIXS spectrometer. A spatial resolution of $19.71 \pm 0.7~μ\mathrm{m}$ and a resolving power exceeding 10,000 were achieved at an unprecedented frame rate of 47 kHz. Intra-train resolved data measured with a high FEL peak fluence of $1.8~\mathrm{mJ/cm^{2}}$ for a 928.5 eV ph photon energy and 1.1 MHz repetition rate from cupric oxide (CuO) revealed a decrease in the emitted signal by ~10% over a time interval of $340~μ\mathrm{s}$, indicating FEL-induced effects that require monitoring when conducting high-repetition-rate experiments. These results establish the JUNGFRAU-iLGAD as a promising detector to harvest the full potential of the hRIXS spectrometer, and validate its suitability for soft X-ray applications.

physics.ins-det

Results of the 2022 ECFA Early-Career Researchers Panel survey on career prospects and diversity

This document presents the outcomes of a comprehensive survey conducted among early career researchers (ECRs) in academic particle physics. Running from September 24, 2022, to March 3, 2023, the survey gathered responses from 759 ECRs employed in 39 countries. The study aimed to gain insights into the career prospects and experiences of ECRs while also delving into diversity and sociological aspects within particle physics research. The survey results are presented in a manner consistent with the survey choices. The document offers insights for the particle physics community, and provides a set of recommendations for enhancing career prospects, fostering diversity, and addressing sociological dimensions within this field.

physics.soc-ph

Characterization of iLGADs using soft X-rays

Experiments at synchrotron radiation sources and X-ray Free-Electron Lasers in the soft X-ray energy range ($250$eV--$2$keV) stand to benefit from the adaptation of the hybrid silicon detector technology for low energy photons. Inverse Low Gain Avalanche Diode (iLGAD) sensors provide an internal gain, enhancing the signal-to-noise ratio and allowing single photon detection below $1$keV using hybrid detectors. In addition, an optimization of the entrance window of these sensors enhances their quantum efficiency (QE). In this work, the QE and the gain of a batch of different iLGAD diodes with optimized entrance windows were characterized using soft X-rays at the Surface/Interface:Microscopy beamline of the Swiss Light Source synchrotron. Above $250$eV, the QE is larger than $55\%$ for all sensor variations, while the charge collection efficiency is close to $100\%$. The average gain depends on the gain layer design of the iLGADs and increases with photon energy. A fitting procedure is introduced to extract the multiplication factor as a function of the absorption depth of X-ray photons inside the sensors. In particular, the multiplication factors for electron- and hole-triggered avalanches are estimated, corresponding to photon absorption beyond or before the gain layer, respectively.

physics.ins-det

The ECFA Early Career Researcher's Panel: composition, structure, and activities, 2021 -- 2022

The European Committee for Future Accelerators (ECFA) Early Career Researcher's (ECR) panel, which represents the interests of the ECR community to ECFA, officially began its activities in January 2021. In the first two years, the panel has defined its own internal structure, responded to ECFA requests for feedback, and launched its own initiatives to better understand and support the diverse interests of early career researchers. This report summarises the panel composition and structure, as well as the different activities the panel has been involved with during the first two years of its existence.

physics.acc-ph

Development of LGAD sensors with a thin entrance window for soft X-ray detection

We show the developments carried out to improve the silicon sensor technology for the detection of soft X-rays with hybrid X-ray detectors. An optimization of the entrance window technology is required to improve the quantum efficiency. The LGAD technology can be used to amplify the signal generated by the X-rays and to increase the signal-to-noise ratio, making single photon resolution in the soft X-ray energy range possible. In this paper, we report first results obtained from an LGAD sensor production with an optimized thin entrance window. Single photon detection of soft X-rays down to 452~eV has been demonstrated from measurements, with a signal-to-noise ratio better than 20.

physics.ins-det

Results of the 2021 ECFA Early-Career Researcher Survey on Training in Instrumentation

The European Committee for Future Accelerators (ECFA) Early-Career Researchers (ECR) Panel was invited by the ECFA Detector R&D Roadmap conveners to collect feedback from the European ECR community. A working group within the ECFA ECR panel held a Townhall Meeting to get first input, and then designed and broadly circulated a detailed survey to gather feedback from the larger ECR community. A total of 473 responses to this survey were received, providing a useful overview of the experiences of ECRs in instrumentation training and related topics. This report summarises the feedback received, and is intended to serve as an input to the ECFA Detector R&D Roadmap process.

physics.ins-det

Process Quality Control Strategy for the Phase-2 Upgrade of the CMS Outer Tracker and High Granularity Calorimeter

Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions. The upgraded CMS Outer Tracker and parts of the new CMS High Granularity Calorimeter (HGCAL) will encompass over $50{,}000$ new silicon sensors covering a total area of about $800\,\text{m}^{2}$. The sensor series production requires a dedicated strategy to monitor the quality and stability of the production process. The strategy is based on a test structure set that provides quick and easy access to critical process parameters. These include parameters not directly accessible on the sensors (e.g. oxide charge concentration and interface trap density) and parameters requiring potentially destructive measurements (e.g. dielectric strength). The set is implemented at least twice on each production wafer. It is divided into test structures for initial evaluation of the most relevant process parameters and structures for in-depth analysis. All structures can be contacted using a 20-needle probe card and an automated positioning stage. With this system, the initial analysis of one wafer is possible in about 30 minutes. In this paper, the CMS collaboration presents the quality assurance plan for the Phase-2 Upgrade with a focus on process quality control. We cover sensor process specifics, the layout of the test structure set that will be implemented in the production runs for the CMS Outer Tracker and HGCAL, and measurement results illustrating the functionality of the included test structures.

physics.ins-det