Searcharxiv⌕ Search

arXiv subjects

Vinícius A. Lacerda

Publications and source records attributed to Vinícius A. Lacerda.

4 recordsLinked to original sources

Enabling Small-Signal Stability Analysis of Black-Box Voltage Source Converters in Large-Scale Modern Power Systems

Modern power systems increasingly rely on power electronic converters, yet many of these devices are provided as black-box models, limiting the applicability of conventional small-signal analysis (SSA) tools. This work presents a unified multi-variable fitted state-space (SSA-FITSS) methodology that enables accurate small-signal modeling of black-box Voltage Source Converters (VSCs) using frequency-domain (FD) identification, adaptive pole-expansion, and reduced-order realization. The method includes an automated state-interpretation strategy that assigns fitted states to representative control-loop categories based on their dominant frequency ranges, providing an approximate but meaningful physical interpretation of the identified dynamics. This capability allows extensive modal analysis, including eigenvalue sensitivities and participation factors, in systems where internal converter details are unavailable. The methodology is validated on a grid-following (GFL) VSC and applied to the New England system, which contains multiple black-box converters operating in both GFL and grid-forming (GFM) modes. Results show that the SSA-FITSS models accurately reproduce converter and system dynamics, support full eigenvalue-based analysis, and reveal stability limits under varying synchronous generation and GFL penetration levels. The approach overcomes key limitations of existing identification-based techniques by enabling scalable, interpretable, and system-wide stability assessment.

eess.SY↗

Performance of Differential Protection Applied to Collector Cables of Offshore Wind Farms with MMC-HVDC Transmission

The ongoing global transition towards low-carbon energy has propelled the integration of offshore wind farms, which, when combined with Modular Multilevel Converter-based High-Voltage Direct Current (MMC-HVDC) transmission, present unique challenges for power system protection. In collector cables connecting wind turbines to offshore MMC, both ends are supplied by Inverter-Based Resources (IBRs), which modify the magnitude and characteristics of fault currents. In this context, this paper investigates the limitations of conventional differential protection schemes under such conditions and compares them with enhanced strategies that account for sequence components. Using electromagnetic transient simulations of a representative offshore wind farm modeled in PSCAD/EMTDC software, internal and external fault scenarios are assessed, varying fault types and resistances. The comparative evaluation provides insights into the sensitivity and selectivity of differential protection and guides a deeper conceptual understanding of the evolving protection challenges inherent to future converter-dominated grids.

eess.SY↗

SIaD-Tool: A Comprehensive Frequency-Domain Tool for Small-Signal Stability and Interaction Assessment in Modern Power Systems

This paper presents SIaD-Tool, an open-source frequency-domain (FD) scanning solution for stability and interaction assessment in modern power systems. The tool enables multi-sequence identification in the abc, dq0, and 0pn frames and supports both series voltage and parallel current perturbation strategies. A novel perturbation scheme allows direct scanning in the target frame, simplifying the analysis of coupling effects and mirrored frequencies. SIaD-Tool is implemented on a multi-platform architecture, including MATLAB/Simulink and Python-PSCAD/EMTDC. Beyond system identification, it integrates automated stability evaluation through four standardized methods: Generalized Nyquist Criterion (GNC), modal impedance analysis, phase margin assessment, and passivity checks. Validation is carried out via extensive case studies involving passive elements, grid-following and grid-forming converters, offshore wind power plants, and the IEEE 9-bus system. Results confirm high accuracy, scalability, and robustness in detecting critical modes, interaction frequencies, oscillatory behavior, and stability margins.

eess.SY↗

Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks

This paper investigates how grid-forming (GFM) and grid-following (GFL) control strategies in inverter-based resources (IBRs) influence line distance and differential protection in converter-dominated transmission systems. A modified IEEE 39-bus system is evaluated with GFM and GFL units equipped with low-voltage ride-through logic, current limiting, and positive- or negative-sequence prioritization. Distance protection is implemented with a mho characteristic, while line differential protection uses an alpha-plane approach. Results show that phase-to-ground loops in distance protection can substantially overestimate the fault location near the Zone-1 reach. For line differential protection, external faults may cause the operating point to briefly enter the trip region of the alpha-plane, even for the healthy-phase in ABG faults under GFL control and during the initial moments of the fault, demanding strong external security measures. These findings highlight that modern converter controls, together with current limitation and sequence-current prioritization, can compromise the reliability and security of traditional protection schemes.

eess.SY↗