Vladimir Bashkirov

Publications and source records attributed to Vladimir Bashkirov.

5 recordsLinked to original sources

Toward Ionization Cluster Size Measurements with a Compact Nanodosimeter

Nanodosimetry aims to provide measurable quantities related to the nanoscopic particle track structure, which determines the biological effectiveness of radiation. While simulated nanodosimetry has already demonstrated its potential for radiation treatment planning, the experimental realization of practical nanodosimetric detectors is still in its early stages. In this work, a nanodosimetric prototype operated with low-pressure gas was developed to count ionizations in a nanometer-equivalent sensitive gas volume. Its performance was evaluated experimentally with alpha beams from an Am-241 source in 1 mbar propane gas. The results support the further development of this compact nanodosimeter class, with potential applications in particle therapy, radiation protection, and space radiation dosimetry.

physics.ins-det↗

Experimental and Monte Carlo Simulation Studies to Investigate the Working Principle of Compact Nanodosimeters

In recent years, compact nanodosimetric detectors based on ion multiplication in low-pressure gas have been developed and gained attention in the scientific community. These detectors use strong electric fields to collect and multiply positive ions produced by the incident radiation in mm-sized cell holes in dielectric materials, achieving a nm-equivalent spatial resolution of the localization of ionization events, when scaled to liquid water at unit density. Their design assumes that ion-impact ionizations of gas molecules within the cell holes dominate signal formation, yet this assumption has lacked direct physical verification. Electron emission from the cell hole walls or the cathode due to ion-impact could also contribute, requiring alternative designs to optimize efficiency. To investigate the relative importance of the possible mechanisms, a nanodosimetric detector featuring a single cell hole with a diameter of 1.5 mm in a dielectric plate was developed. Ion collection and multiplication were achieved by applying a negative high voltage to the glass cathode 0.5 mm below the cell hole, assisted by a low drift field above the plate. A grounded readout electrode with a 0.8 mm hole covers the cell hole to prevent interactions of collected ions with the hole walls. High signal yields in 1 mbar and 2 mbar propane gas were observed and indicated that ion-impact ionizations of the gas molecules could indeed be the primary mechanism for signal induction. Ion-induced secondary electron emission from the cathode was identified as another potential contribution. The compact nanodosimeter setup was further modeled with Geant4-DNA and Garfield++ for deeper insight. The results of these studies are important for understanding and developing a new class of nanodosimeters with potential applications in particle therapy, radiation protection, space dosimetry, and particle physics.

physics.ins-det↗

A Prototype Scintillator Real-Time Beam Monitor for Ultra-high Dose Rate Radiotherapy

FLASH Radiotherapy (RT) is a potentially new cancer radiotherapy technique where an entire therapeutic dose is delivered in about 0.1 s and at ~1000 times higher dose rate than in conventional RT. For clinical trials to be conducted safely, precise and fast beam monitoring that can generate an out-of-tolerance beam interrupt is required. A FLASH Beam Scintillator Monitor (FBSM) is being developed based in part on a novel proprietary inorganic hybrid scintillator material. The FBSM provides large area coverage, low mass profile, linear response over a broad dynamic range, radiation tolerance, and real-time analysis IEC-compliant fast beam-interrupt signal. This paper includes the design concept and test results from a prototype device in radiation beams that include heavy ions, FLASH level dose per pulse electron beams, anda hospital radiotherapy clinic with electron beams. Results include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. The scintillator showed a small -0.02%/kGy signal decrease after a 212 kGy cumulative dose resulting from continuous exposure for 15 minutes at a FLASH compatible dose rate of 234 Gy/s. These tests established the linear response of the FBSM with respect to dose per pulse. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile. At 20 kfps or 50 microsec/frame, the real-time FPGA based computation and analysis of beam position, beam shape, and beam dose takes < 1 microsec.

physics.med-ph↗

A Highly Accelerated Parallel Multi-GPU based Reconstruction Algorithm for Generating Accurate Relative Stopping Powers

Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stopping Power (RSP) measurements with high accuracy within clinically required time frames. Generating accurate RSP values within the shortest amount of time is considered a key goal when developing a pCT software. The existing pCT softwares have successfully met this time frame and even succeeded this time goal, but requiring clusters with hundreds of processors. This paper describes a novel reconstruction technique using two Graphics Processing Unit (GPU) cores, such as is available on a single Nvidia P100. The proposed reconstruction technique is tested on both simulated and experimental datasets and on two different systems namely Nvidia K40 and P100 GPUs from IBM and Cray. The experimental results demonstrate that our proposed reconstruction method meets both the timing and accuracy with the benefit of having reasonable cost, and efficient use of power.

physics.med-ph↗

Mapping the Sensitive Volume of an Ion-Counting Nanodosimeter

We present two methods of independently mapping the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors inherent in both methods are quantified.

physics.ins-det↗