Searcharxiv⌕ Search

arXiv subjects

Vladimir V. Berdnikov

Publications and source records attributed to Vladimir V. Berdnikov.

3 recordsLinked to original sources

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron-positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, enabling continuous real-time monitoring of the photon flux and the recording of $e^+e^-$ pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

physics.ins-det↗

The beam test facility at Jefferson Lab for the precise energy measurement of future calorimeter concepts

In experimental nuclear physics (NP), high-precision electromagnetic calorimetry typically requires a good energy resolution and linear photosensor response on the level of (1-2)% over a full dynamic range of the detector. The beam of secondary leptons at the Jefferson Lab experimental complex, provided by the Hall D pair spectrometer (PS), is an optimal facility for studies aiming to understand the impact of light collection and signal processing on calorimetry energy resolution under real experimental conditions. The light emission and collection processes depend on radiator component quality and type, while signal processing depends on photosensor type and front-end electronics design. Various calorimeter tower components and detector assemblies for current and future NP experiments were tested within the lepton momentum range of (3-6) GeV/c using PS. The energy resolution of the PS itself is estimated to be better than approximately 0.6%.

physics.ins-det↗

Streaming readout for next generation electron scattering experiment

Current and future experiments at the high intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard `triggered' data acquisition systems with a new, simplified and outperforming scheme. `Streaming readout' (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper we report results of the on-beam validation of the Jefferson Lab SRO framework. We exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.