Searcharxiv⌕ Search

arXiv subjects

Vladislav Balagura

Publications and source records attributed to Vladislav Balagura.

5 recordsLinked to original sources

Van der Meer Scan Luminosity Measurement and Beam-Beam Correction

The main method for calibrating the luminosity at Large Hadron Collider (LHC) is van der Meer scan where the beams are swept transversely across each other. This beautiful method was invented in 1968. Despite the honourable age, it remains the preferable tool at hadron colliders. It delivers the lowest calibration systematics, which still often dominates the overall luminosity uncertainty at LHC experiments. Various details of the method are discussed in the paper. One of the main factors limiting proton-proton van der Meer scan accuracy is the beam-beam electromagnetic interaction. It modifies the shapes of the colliding bunches and biases the measured luminosity. In the first years of operation, four main LHC experiments did not attempt to correct the bias because of its complexity. In 2012 a correction method was proposed and then subsequently used by all experiments. It was based, however, on a simplified linear approximation of the beam-beam force and, therefore, had limited accuracy. In this paper, a new simulation is presented, which takes into account the exact non-linear force. Depending on the beam parameters, the results of the new and old methods differ by $\sim1\%$. This needs to be propagated to all LHC cross-section measurements after 2012. The new simulation is going to be used at LHC in future luminosity calibrations.

hep-ex↗

ILD Silicon Tungsten Electromagnetic Calorimeter First Full Scale Electronic Prototype

The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a full length detecting layer (1.60m for the ILD barrel). Indeed, this length induces difficulties for clock and signal propagation and data integrity. The design used for short length slabs had to be adapted on the basis of a simulation study. The long slab performance has been tested with cosmics, radioactive source and with 3 GeV electrons in the beam tests at DESY, Hamburg. The results of the per-channel calibration of the detector are presented. In DESY beam tests we have accumulated data for both normal and inclined incidence of the beam. With the latter one particle can sometimes traverse two pixels and deposit less energy per pixel. We show how this can be used to measure the position of the trigger threshold. This new prototype gives us a lot of hints on how to improve the design of the front-end electronics. It is also a convenient tool to estimate the key characteristics of ILD SiW-Ecal (like power consumption, cooling, readout time etc.) and to optimize the future design of the detector.

physics.ins-det↗

Reconstruction of physics objects at the Circular Electron Positron Collider with Arbor

After the Higgs discovery, precise measurements of the Higgs properties and the electroweak observables become vital for the experimental particle physics. A powerful Higgs/Z factory, the Circular Electron Positron Collider(CEPC) is proposed. The Particle Flow oriented detector design is proposed to the CEPC and a Particle Flow algorithm, Arbor is optimized accordingly. We summarize the physics object reconstruction performance of the Particle Flow oriented detector design with Arbor algorithm and conclude that this combination fulfills the physics requirement of CEPC.

hep-ex↗

Reconstruction and classification of tau lepton decays with ILD

Tau-lepton decays with up to two $π^0$'s in the final state, $τ^+ \to π^+ \barν_τ$, $ρ^+ (π^+π^0) \barν_τ$, $a^+_1 (π^+π^0π^0) \barν_τ$, are used to study the performance of the barrel part of the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) of the International Large Detector (ILD) at the future $e^+-e^-$ International Linear Collider. A correct reconstruction of the tau decay mode is crucial for constraining the tau spin state and measuring the Higgs boson CP state in $H\to τ^+τ^-$ decays. About 95% of $π^+ \barν_τ$ and 90% of $ρ^+\barν_τ$ and $a^+_1\barν_τ$ decays from $e^+e^-\to Z^0\to τ^+τ^-$ reaction at $e^\pm$-beam energy of 125 GeV are correctly reconstructed. In a smaller ILD detector, with Si-W ECAL radius reduced by about 20% these numbers degrade by at most 2%. The $π^0$ mass resolution stays below 10%. Since the failures in the tau-lepton reconstruction are mainly due to photons, the increase of the ILD magnetic field from 3.5 T to 4 T does not bring any significant improvement.

physics.ins-det↗

Notes on van der Meer Scan for Absolute Luminosity Measurement

An absolute luminosity can be measured in an accelerator by sweeping beams transversely across each other in the so called van der Meer scan. We prove that the method can be applied in the general case of arbitrary beam directions and a separation scan plane. A simple method to develop an image of the beam in its transverse plane from spatial distributions of interaction vertexes is also proposed. From the beam images one can determine their overlap and the absolute luminosity. This provides an alternative way of the luminosity measurement during van der Meer scan.

physics.ins-det↗