Spiral Blurring Correction with Water-Fat Separation for Magnetic Resonance Fingerprinting in the Breast

PURPOSE: Magnetic Resonance Fingerprinting (MRF) with spiral readout enables rapid quantification of tissue relaxation times. However, it is prone to blurring due to off-resonance effects. Hence, fat blurring into adjacent regions might prevent identification of small tumors by their quantitative T1 and T2 values. This study aims to correct for the blurring artifacts, thereby enabling fast quantitative mapping in the female breast. METHODS: The impact of fat blurring on spiral MRF results was first assessed by simulations. Then, MRF was combined with 3-point Dixon water-fat separation and spiral blurring correction based on conjugate phase reconstruction. The approach was assessed in phantom experiments and compared to Cartesian reference measurements, namely inversion recovery (IR), multi-echo spin echo (MESE) and Cartesian MRF, by normalized root mean square error (NRMSE) and standard deviation (STD) calculations. Feasibility is further demonstrated in-vivo for quantitative breast measurements of 6 healthy female volunteers, age range 24-31 years. RESULTS: In the phantom experiment, the blurring correction reduced the NRMSE per phantom vial on average from 16% to 8% for T1 and from 18% to 11% for T2 when comparing spiral MRF to IR/MESE sequences. When comparing to Cartesian MRF, the NRMSE reduced from 15% to 8% for T1 and from 12% to 7% for T2. Furthermore, STDs decreased. In-vivo, the blurring correction removed fat bias on T1/T2 from a rim of about 7-8 mm width adjacent to fatty structures. CONCLUSION: The blurring correction for spiral MRF yields improved quantitative maps in the presence of water and fat.

physics.med-ph↗

A novel DOI Positioning Algorithm for Monolithic Scintillator Crystals in PET based on Gradient Tree Boosting

Monolithic crystals are examined as an alternative to segmented scintillator arrays in positron emission tomography (PET). Monoliths provide good energy, timing and spatial resolution including intrinsic depth of interaction (DOI) encoding. DOI allows reducing parallax errors (radial astigmatism) at off-center positions within a PET ring. We present a novel DOI-estimation approach based on the supervised machine learning algorithm gradient tree boosting (GTB). GTB builds predictive regression models based on sequential binary comparisons (decision trees). GTB models have been shown to be implementable in FPGA if the memory requirement fits the available resources. We propose two optimization scenarios for the best possible positioning performance: One restricting the available memory to enable a future FPGA implementation and one without any restrictions. The positioning performance of the GTB models is compared with a DOI estimation method based on a single DOI observable (SO) comparable to other methods presented in literature. For a 12 mm high monolith, we achieve an averaged spatial resolution of 2.15 mm and 2.12 mm FWHM for SO and GTB models, respectively. In contrast to SO models, GTB models show a nearly uniform positioning performance over the whole crystal depth.

physics.med-ph↗

Initial Measurements with the PETsys TOFPET2 ASIC Evaluation Kit and a Characterization of the ASIC TDC

For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds (D_T1) in the timing branch from vth_t1 = 5 - 30. The overvoltage was varied in a range of 1.25 V - 7.25 V. The ambient temperature was kept at 16°C. For all measurements, we performed an energy calibration including a correction for saturation. We evaluated the energy resolution, the coincidence resolving time (CRT) and the coincidence rate. At an overvoltage of 6 V, we obtained an energy resolution of about 10% FWHM, a CRT of approximately 210 ps FWHM and 400 ps FWTM, the coincidence rate showed only small variations of about 5%. To investigate the influence of the ambient temperature, it was varied between 12°C - 20°C. At 12°C and an overvoltage of 6.5 V, a CRT of approx. 195 ps FWHM and an energy resolution of about 9.5% FWHM could be measured. Observed satellite peaks in the time difference spectra were investigated in more detail. We could show that the location of the satellite peaks is correlated with a programmable delay element in the trigger circuit.

physics.ins-det↗

Initial PET Performance Evaluation of a Preclinical Insert for PET/MRI with Digital SiPM Technology

Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of 1 mm pitch and 12 mm in height, digital silicon photomultipliers (DPC 3200-22, Philips Digital Photon Counting) (DPC) are used. The basic PET performance in terms of energy resolution, coincidence resolution time (CRT) and sensitivity as a function of operating parameters, such as the operating temperature, the applied overvoltage, activity and configuration parameters of the DPCs, were evaluated on system level. The measured energy resolution did not show a large dependency on the selected parameters and is in the range of 12.4-12.9% for low activities and degrades to ~13.6% at activities of ~100 MBq. The CRT strongly depends on the selected trigger scheme (trig) of the DPCs. We measured approximately 260 ps, 440 ps, 540 ps and 1300 ps for trig 1-4, respectively. The trues sensitivity for a NEMA NU 4 mouse-sized scatter phantom with a 70-mm-long tube of activity was dependent on the operating parameters and was determined to be 0.4-1.4% at low activities. The random fraction stayed below 5% at activities up to 100 MBq and the scatter fraction was evaluated as ~6% for an energy window of 411-561 keV and ~16% for 250-625 keV. Furthermore, we performed imaging experiments using a mouse-sized hot-rod phantom and a large rabbit-sized phantom. In 2D slices of the reconstructed mouse-sized hot-rod phantom (Ø = 28 mm), the rods were distinguishable from each other down to a rod size of 0.8 mm. There was no benefit of the better CRT of trig 1 over trig 3, where in the larger rabbit-sized phantom (Ø = 114 mm), we could show a clear improvement of image quality using the time-of-flight information.

physics.ins-det↗