SearcharxivSearch

arXiv subjects

W. -M. Zhang

Publications and source records attributed to W. -M. Zhang.

3 recordsLinked to original sources

JLab Measurements of the 3He Form Factors at Large Momentum Transfers

The charge and magnetic form factors, FC and FM, of 3He have been extracted in the kinematic range 25 fm-2 < Q2 < 61 fm-2 from elastic electron scattering by detecting 3He recoil nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility at Jefferson Lab. The measurements are indicative of a second diffraction minimum for the magnetic form factor, which was predicted in the Q2 range of this experiment, and of a continuing diffractive structure for the charge form factor. The data are in qualitative agreement with theoretical calculations based on realistic interactions and accurate methods to solve the three-body nuclear problem.

nucl-ex

JLab Measurement of the $^4$He Charge Form Factor at Large Momentum Transfers

The charge form factor of $^$4He has been extracted in the range 29 fm$^{-2}$ $\le Q^2 \le 77$ fm$^{-2}$ from elastic electron scattering, detecting $^4$He nuclei and electrons in coincidence with the High Resolution Spectrometers of the Hall A Facility of Jefferson Lab. The results are in qualitative agreement with realistic meson-nucleon theoretical calculations. The data have uncovered a second diffraction minimum, which was predicted in the $Q^2$ range of this experiment, and rule out conclusively long-standing predictions of dimensional scaling of high-energy amplitudes using quark counting.

nucl-ex

The TOFp/pVPD Time of Flight System for STAR

A time-of-flight system was constructed for the STAR Experiment for the direct identification of hadrons produced in 197Au+197Au collisions at RHIC. The system consists of two separate detector subsystems, one called the pVPD (the "start" detector) and the other called the TOFp tray (the "stop" detector). Each detector is based on conventional scintillator/phototube technology and includes custom high-performance front-end electronics and a common CAMAC-based digitization and read-out. The design of the system and its performance during the 2001 RHIC run will be described. The start resolution attained by the pVPD was 24 ps, implying a pVPD single-detector resolution of 58 ps. The total time resolution of the system averaged over all detector channels was 87 ps, allowing direct pi/K/p discrimination for momenta up to 1.8 GeV/c, and direct (pi+K)/p discrimination up to 3 GeV/c.

nucl-ex