SearcharxivSearch

arXiv subjects

W. Bertoli

Publications and source records attributed to W. Bertoli.

5 recordsLinked to original sources

ECLAIRs: the SVOM high-energy transient trigger camera

The core instrument of the SVOM Gamma-ray burst mission launched in June 2024 is the 4-150 keV 2-D coded mask camera ECLAIRs responsible for the autonomous trigger and localization of transient events within its field of view. The flight model of ECLAIRs has been built by several French labs (IRAP, CEA, APC) under the supervision of the French Space Agency (CNES), while APC, LUPM and IAP built a suite of data reduction and analysis software. This paper outlines the main science goals of ECLAIRs and describes the different instrument sub-systems and their main characteristics. The paper then discusses the instrument configuration and operation as well as the main in-flight measured performances. Finally, the paper summarizes the science performance of ECLAIRs up to March 31, 2025.

astro-ph.HE

The coded mask of the ECLAIRs telescope onboard the SVOM space mission

ECLAIRs is a hard X-ray coded-mask telescope onboard the SVOM space mission, designed to detect and localize high-energy transients, in particular gamma-ray bursts. Operating over the 4-150 keV energy range, ECLAIRs extends coded-mask imaging to an unusually low-energy threshold. Achieving sensitivity down to 4 keV while maintaining performance up to 150 keV motivated the development of a novel self-supporting coded mask. This design addresses both scientific and mechanical challenges through dedicated pattern-generation algorithms and an innovative stiffened sandwich structure. We present the rationale, development, and final implementation of the ECLAIRs coded mask.

astro-ph.HE

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

physics.ins-det

The camera of the fifth H.E.S.S. telescope. Part I: System description

In July 2012, as the four ground-based gamma-ray telescopes of the H.E.S.S. (High Energy Stereoscopic System) array reached their tenth year of operation in Khomas Highlands, Namibia, a fifth telescope took its first data as part of the system. This new Cherenkov detector, comprising a 614.5 m^2 reflector with a highly pixelized camera in its focal plane, improves the sensitivity of the current array by a factor two and extends its energy domain down to a few tens of GeV. The present part I of the paper gives a detailed description of the fifth H.E.S.S. telescope's camera, presenting the details of both the hardware and the software, emphasizing the main improvements as compared to previous H.E.S.S. camera technology.

astro-ph.IM

The silicon micro-strip detector plane for the LOFT/Wide Field Monitor

The main objective of the Wide Field Monitor (WFM) on the LOFT mission is to provide unambiguous detection of the high-energy sources in a large field of view, in order to support science operations of the LOFT primary instrument, the LAD. The monitor will also provide by itself a large number of results on the timing and spectral behaviour of hundreds of galactic compact objects, Active Galactic Nuclei and Gamma-Ray Bursts. The WFM is based on the coded aperture concept where a position sensitive detector records the shadow of a mask projected by the celestial sources. The proposed WFM detector plane, based on Double Sided micro-Strip Silicon Detectors (DSSD), will allow proper 2-dimensional recording of the projected shadows. Indeed the positioning of the photon interaction in the detector with equivalent fine resolution in both directions insures the best imaging capability compatible with the allocated budgets for this telescope on LOFT. We will describe here the overall configuration of this 2D-WFM and the design and characteristics of the DSSD detector plane including its imaging and spectral performances. We will also present a number of simulated results discussing the advantages that this configuration offers to LOFT. A DSSD-based WFM will in particular reduce significantly the source confusion experienced by the WFM in crowded regions of the sky like the Galactic Center and will in general increase the observatory science capability of the mission.

astro-ph.IM