Searcharxiv⌕ Search

arXiv subjects

W. Hofmann

Publications and source records attributed to W. Hofmann.

216 records · Page 12Linked to original sources

Monte Carlo studies on the sensitivity of the HEGRA imaging atmospheric Cerenkov telescope system in observations of extended gamma-ray sources

In this paper, we present the results of Monte Carlo simulations of atmospheric showers induced by diffuse gamma rays as detected by the high-energy gamma ray astronomy (HEGRA) system of five imaging atmospheric Cerenkov telescopes (IACTs). We have investigated the sensitivity of observations on extended gamma ray emission over the entire field of view of the instrument. We discuss a technique to search for extended gamma ray sources within the field of view of the instrument. We give estimates for HEGRA sensitivity of observations on extended TeV gamma ray sources.

astro-ph↗

Measurement of the Cherenkov light spectrum and of the polarization with the HEGRA-IACT-system

The HEGRA system of Imaging Atmospheric Cherenkov Telescopes (IACTs) detects Cherenkov light produced by air showers. The concept of stereoscopic observation with the five HEGRA telescopes allows the reconstruction of various shower parameters, for example the shower direction, the location of the shower core and the energy of cosmic rays. One of the telescopes was modified so that measurements of the spectrum and the polarization of Cherenkov light with the HEGRA system were possible. The experimental setup is described and preliminary results presented.

astro-ph↗

Search for point sources and diffuse emission from the Galactic plane with the HEGRA-IACT-system

The HEGRA-IACT-system with a FoV of ~1.5 deg radius has been used for surveying one quater of the Galactic disc in respect to point sources, moderately extended sources and for diffuse emission in the energy range above 1 TeV. In total 140 h of good observation time were accumulated. No new source has been discoverd. Limits on the level of 20% or lower of the Crab flux on about 87 potential sources like SNR, Pulsars and EGRET sources are derived. A limit on the diffuse emission is given on the level of dPhi/dE(E=1 TeV) = 6.1 10^-15 ph cm-2 s-1 sr-1 Mev-1 resulting in a lower limit of 2.5 on the spectral index for the extrapolation of the meassured EGRET flux for the diffuse emission.

astro-ph↗

Study of the photon flux from the night sky at La Palma and Namibia, in the wavelength region relevant for imaging atmospheric Cherenkov telescopes

The level of the night sky background light at La Palma and Namibia was determined, with emphasis on the wavelength region and solid angle coverage relevant for the operation of imaging atmospheric Cherenkov telescopes. The dependence of the night sky background light both on celestial coordinates (alt, az) and on galactic coordinates (b, l) was measured, with an angular resolution of about 1 degr. Average light levels near the zenith are similar in both locations -- 2.2 x 10^12 to 2.6 x 10^12 photons per sr s m^2 for 300 nm < lambda < 650 nm. With increasing zenith angle the level of background light increases at La Palma, whereas a constant level is measured in Namibia. Near the center of the Milky Way, background light levels are increased by a factor up to 4 and more. Also the level of light backscattered from the ground has been studied.

astro-ph↗

Particle Identification by Multifractal Parameters in Gamma-Astronomy with the HEGRA-Cherenkov-Telescopes

Cherenkov images of air showers can also be classified using multifractal and wavelet parameters, as compared to the conventional Hillas image parameters. This technique was applied to the images recorded by the cameras of the stereoscopic imaging air Cherenkov-telescopes operated by the HEGRA collaboration. With respect to the identification of particles, the performance of multifractal and wavelet parameters was examined using a data sample from the observation of the active galaxy Mkn 501 that showed a high gamma-ray flux. The multifractal parameters were also combined with the Hillas parameters using a neural network approach in order to further improve the gamma/hadron-separation.

astro-ph↗

On the optimum spacing of stereoscopic imaging atmospheric Cherenkov telescopes

For stereoscopic systems of imaging atmospheric Cherenkov telescopes (IACTs), a key parameter to optimize the sensitivity for VHE gamma-ray point sources is the intertelescope spacing. Using pairs of telescopes of the HEGRA IACT system, the sensitivity of two-telescope stereo IACT systems is studied as a function of the telescope spacing, ranging from 70 m to 140 m. Data taken during the 1997 outburst of Mrk 501 are used to evaluate both the detection rates before cuts, and the sensitivity for weak signals after cuts to optimize the significance of signals. Detection rates decrease by about 1/3 between the minimum and maximum spacing. The significance of signals is essentially independent of distance, in the range investigated.

astro-ph↗

Data analysis techniques for stereo IACT systems

Based on data and Monte-Carlo simulations of the HEGRA IACT system, improved analysis techniques were developed for the determination of the shower geometry and shower energy from the multiple Cherenkov images. These techniques allow, e.g., to select subsamples of events with better than 3' angular resolution, which are used to limit the rms radius of the VHE emission region of the Crab Nebula to less than 1.5'. For gamma-rays of the Mrk 501 data sample, the energy can be determined to typically 10% and the core location to 2-3 m.

astro-ph↗

Improved energy resolution for VHE gamma-ray astronomy with systems of Cherenkov telescopes

We present analysis techniques to improve the energy resolution of stereoscopic systems of imaging atmospheric Cherenkov telescopes, using the HEGRA telescope system as an example. The techniques include (i) the determination of the height of the shower maximum, which is then taken into account in the energy determination, and (ii) the determination of the location of the shower core with the additional constraint that the direction of the gamma rays is known a priori. This constraint can be applied for gamma-ray point sources, and results in a significant improvement in the localization of the shower core, which translates into better energy resolution. Combining both techniques, the HEGRA telescopes reach an energy resolution between 9% and 12%, over the entire energy range from 1 TeV to almost 100 TeV. Options for further improvements of the energy resolution are discussed.

astro-ph↗

Effectiveness of TeV Gamma-Ray Observations at Large Zenith Angles with a Stereoscopic System of Imaging Atmospheric Cherenkov Telescopes

The sensitivity of imaging atmospheric Cherenkov telescopes (IACTs) in TeV gamma-ray observations reachs its maximum at small zenith angles (< 30 degree) which provide the minimum attainable energy threshold of an instrument. However, for a specific telescope site a number of gamma-ray sources, or source candidates, can only be observed at much larger zenith angles (< 60 degree). Moreover the observations at large zenith angles allow to extend the observation time window for any object seen at small zenith angles, as well as to enlarge the dynamic energy range of an instrument towards the highest observable energies of gamma-rays. Based on Monte Carlo simulations we present here the results on the sensitivity of a stereoscopic system of 5 IACTs in observations at large zenith angles. We point out some important parameters of the telescope design which could substantially improve the efficiency of such observations with forthcoming IACT arrays like CANGAROO III, HESS and VERITAS.

astro-ph↗

Comparison of techniques to reconstruct VHE gamma-ray showers from multiple stereoscopic Cherenkov images

For air showers observed simultaneously by more than two imaging atmospheric Cherenkov telescopes, the shower geometry is overconstrained by the images and image information should be combined taking into account the quality of the images. Different algorithms are discussed and tested experimentally using data obtained from observations of Mkn 501 with the HEGRA IACT system. Most of these algorithms provide an estimate of the accuracy of the reconstruction of shower geometry on an event-by-event basis, allowing, e.g., to select higher-quality subsamples for precision measurements.

astro-ph↗

Locating TeV Gamma-Ray Sources with Sub-Arcminute Precision: the Pointing Calibration of the HEGRA System of Imaging Atmospheric Cherenkov Telescopes

Stereoscopic viewing of TeV gamma-ray air showers with systems of Imaging Atmospheric Cherenkov Telescopes (IACTs) allows to reconstruct the origin of individual primary particles with an accuracy of 0.1 degree or better. The shower impact point can be determined within 15 meters. To actually achieve this resolution, the pointing of the telescopes of an IACT system needs to be controlled with high precision. For the HEGRA IACT system, a procedure to calibrate telescope pointing was established, using bright stars distributed over the sky as references. On the basis of these measurements, one determines parameters of a correction function which is valid for the complete hemisphere. After correction a pointing accuracy of 0.01 degree is achieved.

astro-ph↗

Changes of the cosmic-ray mass composition in the 10^{14} - 10^{16} eV energy range

Changes of the cosmic-ray mass composition at the `knee' of the cosmic-ray flux spectrum near 10^{15} eV energy are investigated using data from ten Cosmic Ray Tracking (CRT) detectors and the HEGRA air-shower array on La Palma, Canary Islands. The analysis is based on the angular distribution of muons in air showers. Results can be easily expressed in terms of of primary cosmic rays. We find a rise of below 10^{15} eV, consistent with direct measurements. Simple cosmic-ray composition models are presented which are fully consistent with our results as well as the JACEE flux and composition measurements and the flux measurements of the Tibet AS-gamma collaboration.

astro-ph↗

Characteristics of the Multi-Telescope Coincidence Trigger of the HEGRA IACT System

The HEGRA--collaboration is operating a system of imaging atmospheric Cherenkov telescopes to search for sources of TeV-gamma-rays. Air showers are observed in stereoscopic mode with several telescopes simultaneously. To trigger the telescope system a versatile two-level trigger scheme has been implemented, which allows a significant reduction of the energy threshold with respect to single telescopes. The technical implementation of this trigger scheme and the performance of the trigger system are described. Results include the dependence of single- and multi-telescope trigger rates on the trigger thresholds, on the orientation of the telescopes, and on the type of the primary particle.

astro-ph↗

Measuring Gamma-Ray Energy Spectra with the HEGRA IACT System

The stereoscopic reconstruction of air showers viewed by multiple imaging atmospheric Cherenkov telescopes (IACTs) allows a more precise reconstruction of shower energies and hence an improved determination of energy spectra. Reconstruction techniques and in particular new systematic checks are discussed on the basis of the large sample of gamma-rays from Mkn 501 detected with the HEGRA IACT system. (Talk presented at the Workshop ``Towards a Major Atmospheric Cherenkov Detector V'', Kruger Park, South Africa, 1997)

astro-ph↗

An improved technique of image analysis for IACTs and IACT Systems

In order to better utilize the information contained in the shower images generated by imaging Cherenkov telescopes (IACTs) equipped with cameras with small pixels, images are fit to a parametrization of image shapes gained from Monte Carlo simulations, treating the shower direction, impact point, and energy as free parameters. Monte Carlo studies for a system of IACTs predict an improvement of order 1.5 in the angular resolution. The fitting technique can also be applied to single-telescope images; simulations indicate that the shower direction in space can be reconstructed event-by-event with a resolution of 0.16 deg. to 0.20 deg., allowing to generate genuine source maps. Data from Crab observations with a single HEGRA telescope confirm this prediction.

astro-ph↗

Calibration of the Sensitivity of Imaging Atmospheric Cherenkov Telescopes using a Reference Light Source

The sensitivity of an Imaging Atmospheric Cherenkov telescope is calibrated by shining, from a distant pulsed monochromatic light source, a defined photon flux onto the mirror. The light pulse is captured and reconstructed by the telescope in an identical fashion as real Cherenkov light. The intensity of the calibration light pulse is monitored via a calibrated sensor at the telescope; in order to account for the lower sensitivity of this sensor compared to the Cherenkov telescope, an attenuator is inserted in the light source between the measurements with the calibrated sensor, and with the telescope. The resulting telescope sensitivities have errors of 10%, and compare well with other estimates of the sensitivity.

astro-ph↗

Pseudorapidity Distribution of Charged Particles in PbarP Collisions at root(s)= 630GeV

Using a silicon vertex detector, we measure the charged particle pseudorapidity distribution over the range 1.5 to 5.5 using data collected from PbarP collisions at root s = 630 GeV. With a data sample of 3 million events, we deduce a result with an overall normalization uncertainty of 5%, and typical bin to bin errors of a few percent. We compare our result to the measurement of UA5, and the distribution generated by the Lund Monte Carlo with default settings. This is only the second measurement at this level of precision, and only the second measurement for pseudorapidity greater than 3.

hep-ex↗

Triggering of Imaging Air Cherenkov Telescopes: PMT trigger rates due to night-sky photons

Imaging air Cherenkov telescopes are usually triggered on a coincidence of two or sometimes more pixels, with discriminator thresholds in excess of 20 photoelectrons applied for each pixel. These thresholds required to suppress night-sky background are significantly higher than expected on the basis of a Poisson distribution in the number of night-sky photoelectrons generated during the characteristic signal integration time. We studied noise trigger rates under controlled conditions using an artificial background light source. Large tails in the PMT amplitude response to single photoelectrons are identified as a dominant contribution to noise triggers. The rate of such events is very sensitive to PMT operating parameters.

astro-ph↗