SearcharxivSearch

arXiv subjects

W. Lange

Publications and source records attributed to W. Lange.

18 recordsLinked to original sources

Machine Learning-Assisted Measurement of Lepton-Jet Azimuthal Angular Asymmetries in Deep-Inelastic Scattering at HERA

In deep-inelastic positron-proton scattering, the lepton-jet azimuthal angular asymmetry is measured using data collected with the H1 detector at HERA. When the average transverse momentum of the lepton-jet system, $\lvert \vec{P}_\perp \rvert $, is much larger than the total transverse momentum of the system, $\lvert \vec{q}_\perp \rvert$, the asymmetry between parallel and antiparallel configurations, $\vec{P}_\perp$ and $\vec{q}_\perp$, is expected to be generated by initial and final state soft gluon radiation and can be predicted using perturbation theory. Quantifying the angular properties of the asymmetry therefore provides an additional test of the strong force. Studying the asymmetry is important for future measurements of intrinsic asymmetries generated by the proton's constituents through Transverse Momentum Dependent (TMD) Parton Distribution Functions (PDFs), where this asymmetry constitutes a dominant background. Moments of the azimuthal asymmetries are measured using a machine learning method for unfolding that does not require binning.

hep-ex

Measurement of the 1-jettiness event shape observable in deep-inelastic electron-proton scattering at HERA

The H1 Collaboration reports the first measurement of the 1-jettiness event shape observable $\tau_1^b$ in neutral-current deep-inelastic electron-proton scattering (DIS). The observable $\tau_1^b$ is equivalent to a thrust observable defined in the Breit frame. The data sample was collected at the HERA $ep$ collider in the years 2003-2007 with center-of-mass energy of $\sqrt{s}=319\,\text{GeV}$, corresponding to an integrated luminosity of $351.1\,\text{pb}^{-1}$. Triple differential cross sections are provided as a function of $\tau_1^b$, event virtuality $Q^2$, and inelasticity $y$, in the kinematic region $Q^2>150\,\text{GeV}^{2}$. Single differential cross section are provided as a function of $\tau_1^b$ in a limited kinematic range. Double differential cross sections are measured, in contrast, integrated over $\tau_1^b$ and represent the inclusive neutral-current DIS cross section measured as a function of $Q^2$ and $y$. The data are compared to a variety of predictions and include classical and modern Monte Carlo event generators, predictions in fixed-order perturbative QCD where calculations up to $\mathcal{O}(\alpha_s^3)$ are available for $\tau_1^b$ or inclusive DIS, and resummed predictions at next-to-leading logarithmic accuracy matched to fixed order predictions at $\mathcal{O}(\alpha_s^2)$. These comparisons reveal sensitivity of the 1-jettiness observable to QCD parton shower and resummation effects, as well as the modeling of hadronization and fragmentation. Within their range of validity, the fixed-order predictions provide a good description of the data. Monte Carlo event generators are predictive over the full measured range and hence their underlying models and parameters can be constrained by comparing to the presented data.

hep-ex

Measurement of groomed event shape observables in deep-inelastic electron-proton scattering at HERA

The H1 Collaboration at HERA reports the first measurement of groomed event shape observables in deep inelastic electron-proton scattering (DIS) at $\sqrt{s}=319$ GeV, using data recorded between the years 2003 and 2007 with an integrated luminosity of $351$ pb$^{-1}$. Event shapes provide incisive probes of perturbative and non-perturbative QCD. Grooming techniques have been used for jet measurements in hadronic collisions; this paper presents the first application of grooming to DIS data. The analysis is carried out in the Breit frame, utilizing the novel Centauro jet clustering algorithm that is designed for DIS event topologies. Events are required to have squared momentum-transfer $Q^2 > 150$ GeV$^2$ and inelasticity $ 0.2 < y < 0.7$. We report measurements of the production cross section of groomed event 1-jettiness and groomed invariant mass for several choices of grooming parameter. Monte Carlo model calculations and analytic calculations based on Soft Collinear Effective Theory are compared to the measurements.

hep-ex

Observation and differential cross section measurement of neutral current DIS events with an empty hemisphere in the Breit frame

The Breit frame provides a natural frame to analyze lepton-proton scattering events. In this reference frame, the parton model hard interactions between a quark and an exchanged boson defines the coordinate system such that the struck quark is back-scattered along the virtual photon momentum direction. In Quantum Chromodynamics (QCD), higher order perturbative or non-perturbative effects can change this picture drastically. As Bjorken-$x$ decreases below one half, a rather peculiar event signature is predicted with increasing probability, where no radiation is present in one of the two Breit-frame hemispheres and all emissions are to be found in the other hemisphere. At higher orders in $\alpha_s$ or in the presence of soft QCD effects, predictions of the rate of these events are far from trivial, and that motivates measurements with real data. We report on the first observation of the empty current hemisphere events in electron-proton collisions at the HERA collider using data recorded with the H1 detector at a center-of-mass energy of 319 GeV. The fraction of inclusive neutral-current DIS events with an empty hemisphere is found to be $0.0112 \pm 3.9\,\%_\text{stat} \pm 4.5\,\%_\text{syst} \pm 1.6\,\%_\text{mod}$ in the selected kinematic region of $150< Q^2<1500$ GeV$^2$ and inelasticity $0.14< y<0.7$. The data sample corresponds to an integrated luminosity of 351.1 pb$^{-1}$, sufficient to enable differential cross section measurements of these events. The results show an enhanced discriminating power at lower Bjorken-$x$ among different Monte Carlo event generator predictions.

hep-ex

Unbinned Deep Learning Jet Substructure Measurement in High $Q^2$ ep collisions at HERA

The radiation pattern within high energy quark- and gluon-initiated jets (jet substructure) is used extensively as a precision probe of the strong force as well as an environment for optimizing event generators with numerous applications in high energy particle and nuclear physics. Looking at electron-proton collisions is of particular interest as many of the complications present at hadron colliders are absent. A detailed study of modern jet substructure observables, jet angularities, in electron-proton collisions is presented using data recorded using the H1 detector at HERA. The measurement is unbinned and multi-dimensional, using machine learning to correct for detector effects. All of the available reconstructed object information of the respective jets is interpreted by a graph neural network, achieving superior precision on a selected set of jet angularities. Training these networks was enabled by the use of a large number of GPUs in the Perlmutter supercomputer at Berkeley Lab. The particle jets are reconstructed in the laboratory frame, using the $k_{\mathrm{T}}$ jet clustering algorithm. Results are reported at high transverse momentum transfer $Q^2>150$ GeV${}^2$, and inelasticity $0.2 < y < 0.7$. The analysis is also performed in sub-regions of $Q^2$, thus probing scale dependencies of the substructure variables. The data are compared with a variety of predictions and point towards possible improvements of such models.

hep-ex

Measurement of lepton-jet correlation in deep-inelastic scattering with the H1 detector using machine learning for unfolding

The first measurement of lepton-jet momentum imbalance and azimuthal correlation in lepton-proton scattering at high momentum transfer is presented. These data, taken with the H1 detector at HERA, are corrected for detector effects using an unbinned machine learning algorithm OmniFold, which considers eight observables simultaneously in this first application. The unfolded cross sections are compared to calculations performed within the context of collinear or transverse-momentum-dependent (TMD) factorization in Quantum Chromodynamics (QCD) as well as Monte Carlo event generators. The measurement probes a wide range of QCD phenomena, including TMD parton distribution functions and their evolution with energy in so far unexplored kinematic regions.

hep-ex

Determination of the strong coupling constant $α_s(M_Z)$ in next-to-next-to-leading order QCD using H1 jet cross section measurements

The strong coupling constant $α_s(M_Z)$ is determined from inclusive jet and dijet cross sections in neutral-current deep-inelastic $ep$ scattering (DIS) measured at HERA by the H1 collaboration using next-to-next-to-leading order (NNLO) QCD predictions. The dependence of the NNLO predictions and of the resulting value of $α_s(M_Z)$ at the $Z$-boson mass $m_Z$ are studied as a function of the choice of the renormalisation and factorisation scales. Using inclusive jet and dijet data together, the strong coupling constant is determined to be $α_s(M_Z)=0.1166\,(19)_{\rm exp}\,(24)_{\rm th}$. Complementary, $α_s(M_Z)$ is determined together with parton distribution functions of the proton (PDFs) from jet and inclusive DIS data measured by the H1 experiment. The value $α_s(M_Z)=0.1147\,(25)_{\rm tot}$ obtained is consistent with the determination from jet data alone. The impact of the jet data on the PDFs is studied. The running of the strong coupling is tested at different values of the renormalisation scale and the results are found to be in agreement with expectations.

hep-ex

Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam

A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and BeamCal in future linear $e^+e^-$ collider experiments. The detector planes were produced utilising novel connectivity scheme technologies. They were installed in a compact prototype of the calorimeter and tested at DESY with an electron beam of energy 1-5 GeV. The performance of a prototype of a compact LumiCal comprising eight detector planes was studied. The effective Moli`ere radius at 5 GeV was determined to be (8.1 +/- 0.1 (stat) +/- 0.3 (syst)) mm, a value well reproduced by the Monte Carlo (MC) simulation (8.4 +/- 0.1) mm. The dependence of the effective Moli`ere radius on the electron energy in the range 1-5 GeV was also studied. Good agreement was obtained between data and MC simulation.

physics.ins-det

Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up

A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Molière radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.

physics.ins-det

Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II

Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond sensors are widely used. In this paper single crystal sapphire sensors are considered as a promising alternative. Industrially grown sapphire wafers are available in large sizes, are of low cost and, like diamond sensors, can be operated without cooling. Here we present results of an irradiation study done with sapphire sensors in a high intensity low energy electron beam. Then, a multichannel direction-sensitive sapphire detector stack is described. It comprises 8 sapphire plates of 1 cm^2 size and 525 micro m thickness, metallized on both sides, and apposed to form a stack. Each second metal layer is supplied with a bias voltage, and the layers in between are connected to charge-sensitive preamplifiers. The performance of the detector was studied in a 5 GeV electron beam. The charge collection efficiency measured as a function of the bias voltage rises with the voltage, reaching about 10 % at 950 V. The signal size obtained from electrons crossing the stack at this voltage is about 22000 e, where e is the unit charge. The signal size is measured as a function of the hit position, showing variations of up to 20 % in the direction perpendicular to the beam and to the electric field. The measurement of the signal size as a function of the coordinate parallel to the electric field confirms the prediction that mainly electrons contribute to the signal. Also evidence for the presence of a polarisation field was observed.

physics.ins-det

Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.

physics.ins-det

ECFA Detector R&D Panel, Review Report

Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.

physics.ins-det

Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC

The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to the CMS detector, a beam abort is induced. The Fast Beam Conditions Monitor, BCM1F, is a flux counter close to the beam pipe inside the tracker volume. It uses single-crystal CVD diamond sensors, radiation-hard FE electronics, and optical signal transmission to measure the beam halo as well as collision products bunch by bunch. The system has been operational during the initiatory runs of LHC in September 2008. It works reliably since the restart in 2009 and is invaluable to CMS for everyday LHC operation. A characterisation of the system on the basis of data collected during LHC operation is presented.

physics.ins-det

Fast Beam Conditions Monitor BCM1F for the CMS Experiment

The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of different sub-systems measuring either the particle flux near the beam pipe with time resolution between nano- and microseconds or the integrated dose over longer time intervals. This paper presents the Fast Beam Conditions Monitor, BCM1F, which is designed for fast flux monitoring measuring both beam halo and collision products. BCM1F is located inside the CMS pixel detector volume close to the beam-pipe. It uses sCVD diamond sensors and radiation hard front-end electronics, along with an analog optical readout of the signals. The commissioning of the system and its successful operation during the first be ams of the LHC are described.

physics.ins-det

Beam Calorimeter Technologies

Two different technologies are considered for the Beam Calorimeters of the ILC detector. Simulation studies of the performance have been done for a diamond-tungsten sandwich calorimeter and for a homogeneous heavy element crystal calorimeter with optical fiber readout. Studies of the stability and the linearity of a polycrystalline diamond were done for the diamond-tungsten option. For the heavy crystal option the light yield reduction due to the wavelength shifting fiber readout was studied.

physics.ins-det

Raman Sideband Cooling in presence of Multiple Decay Channels

We have investigated the efficiency of pulsed Raman sideband cooling in the presence of multiple decay and excitation channels. By applying sum rules we identify parameter regimes in which multiple scattering of photons can be described by an effective wave vector. Using this method we determine the rate of heating caused by optical pumping inside and outside the Lamb-Dicke regime. On this basis we discuss also the efficiency of a recently proposed scheme for ground-state cooling outside the Lamb-Dicke regime [G. Morigi, J.I. Cirac, M. Lewenstein, and P. Zoller, Europhys. Lett. {\bf 39}, 13 (1997)].

quant-ph

Dynamic generation of maximally entangled photon multiplets by adiabatic passage

The adiabatic passage scheme for quantum state synthesis, in which atomic Zeeman coherences are mapped to photon states in an optical cavity, is extended to the general case of two degenerate cavity modes with orthogonal polarization. Analytical calculations of the dressed-state structure and Monte Carlo wave-function simulations of the system dynamics show that, for a suitably chosen cavity detuning, it is possible to generate states of photon multiplets that are maximally entangled in polarization. These states display nonclassical correlations of the type described by Greenberger, Horne, and Zeilinger (GHZ). An experimental scheme to realize a GHZ measurement using coincidence detection of the photons escaping from the cavity is proposed. The correlations are found to originate in the dynamics of the adiabatic passage and persist even if cavity decay and GHZ state synthesis compete on the same time scale. Beyond entangled field states, it is also possible to generate entanglement between photons and the atom by using a different atomic transition and initial Zeeman state.

quant-ph

Measurement of conditional phase shifts for quantum logic

Measurements of the birefringence of a single atom strongly coupled to a high-finesse optical resonator are reported, with nonlinear phase shifts observed for intracavity photon number much less than one. A proposal to utilize the measured conditional phase shifts for implementing quantum logic via a quantum-phase gate (QPG) is considered. Within the context of a simple model for the field transformation, the parameters of the "truth table" for the QPG are determined.

quant-ph