SearcharxivSearch

arXiv subjects

W. Lauth

Publications and source records attributed to W. Lauth.

At least 19 recordsLinked to original sources

Investigation of Radiation Emitted by Sub GeV Electrons in Oriented Scintillator Crystals

The research investigates coherent interactions between sub-GeV electrons and oriented scintillator crystals, leading to enhanced electromagnetic (EM) radiation. Experiments at Mainz Mikrotron (MAMI) involved PWO, BGO, and CsI crystals oriented along $\langle100\rangle$, $\langle111\rangle$, and $\langle100\rangle$ axes. Enhanced radiation emission was observed when the beam aligned with crystal axes, especially in BGO and CsI for the first time. These findings are crucial for innovative detectors using oriented crystal scintillators, amplifying EM processes along specific crystallographic directions. Potential applications include ultra-compact, highly sensitive electromagnetic calorimeters for high-energy physics and astroparticles, as well as high-performance gamma detectors for nuclear physics and medical imaging.

hep-ex

Beam Steering and Radiation Generation of Electrons in Bent Crystals in the Sub-GeV Domain

We present an investigation into beam steering and radiation emission by sub-GeV electrons traversing bent silicon crystals. Using 855, 600, and 300~MeV electron beams at the Mainz Microtron (MAMI), we explored orientational coherent effects and particle dynamics in a 15~$\mu$m-thick crystal bent along the (111) planes. Combined experimental and simulation analyses enabled the classification and quantitative assessment of the contributions from channeling, dechanneling, rechanneling, and volume capture to both beam deflection and radiation emission. Crystal steering remained effective even at 300~MeV, with measured channeling efficiencies exceeding 50\%, a record at such low energy. Channeling and volume reflection enhanced radiation emission by up to a factor of six compared to the misaligned orientation, highlighting strong orientational coherence effects in the sub-GeV regime. These findings confirm the feasibility of using bent crystals for efficient beam manipulation and high-intensity photon generation at low energies, supporting the development of novel light sources and beam control strategies at accelerator facilities operating in this energy range.

physics.acc-ph

Planar channeling of 855 MeV electrons in a boron-doped (110) diamond undulator -- a case study

A 4-period diamond undulator with a thickness of 20 $\mu$m was produced with the method of Chemical Vapour Deposition (CVD), applying boron doping, on a straight diamond crystal with an effective thickness of 165.5 $\mu$m. A planar (110) channeling experiment was performed with the 855 MeV electron beam of the Mainz Microtron MAMI accelerator facility to observe the expected undulator peak. The search was guided by simulation calculations on a personal computer. The code is based on the continuum potential picture, and a classical electrodynamic expression which involves explicitly the acceleration of the particle. As a result, an unexpected optimal observation angle was figured out, for which the undulator peak is strongest and the channeling radiation from the backing crystal being significantly suppressed. However, an undulator peak was not observed. Implications for the prepared undulator structure are discussed. Scatter distributions were measured for a 75 $\mu$m Kapton, a 25 $\mu$m aluminum foils, and a 70.7 $\mu$m diamond plate in random orientation. The results were compared with Moli\`ere's scatter theory for amorphous medii. Very good agreement was found for Kapton and aluminum while for diamond the experimental width is 21\% smaller. This reduction is interpreted as coherent scattering suppression in single crystals. At tilted injection of the beam with respect to the (110) plane a clear asymmetry was observed which resembles partial beam deflection. We interpret this phenomenon heuristically as re-channeling.

physics.acc-ph

Observation of Fine Structure in Channeling of Particles in Bent Crystals

We observed highly efficient manipulation of the 530 MeV positron beam at Mainz Microtron via bent crystals. The low beam divergence revealed a fine structure in the angular distribution of channeled particles. A compact analytical model, supported by Monte Carlo including multiple scattering, accounts for the measurements. We established a criterion for designing a crystal with reduced angular spread of channeled particles for beam manipulation at any energy. This finding is particularly useful in view of applications of channeling to the highest energies.

physics.acc-ph

High accuracy synchrotron radiation interferometry with relativistic electrons

A high-precision hypernuclear experiment has been performed at the Mainz Microtron (MAMI) to determine the hypertriton Λ binding energy via decay-pion spectroscopy. A key element of this measurement is an accurate calibration of the magnetic spectrometers with the MAMI beam. For such an absolute calibration with small statistical and systematic uncertainties the undulator light interference method will be applied. In this contribution the basic principle of this method is discussed and the analysis status of the measured synchrotron radiation spectra is presented

physics.ins-det

Surface-barrier detector with smoothly tunable thickness of depleted layer for study of ionization loss and dechanneling length of negatively charged particles channeling in a crystal

A new method for the experimental study of ionization loss of relativistic negatively charged particles moving in a crystal in the channeling regime using a semiconductor surface-barrier detector with smoothly tunable thickness of the depleted layer is proposed. The ionization loss can only be measured in the depleted layer of the detector. The thickness of the depleted layer in a flat semiconductor detector can be smoothly regulated by the value of the bias voltage of the detector. Therefore, the energy distribution of the ionization loss of relativistic particles which cross the detector and move in the channeling regime in the detector crystal can be measured along the path of the particles at variation of the bias voltage of the detector. Ionization loss spectra should be different for channeling and nonchanneling particles, and both fractions can be determined. The application of a Si surface-barrier detector-target is considered. Measurements with such a detector would make it possible to study: the energy distribution of ionization loss of channeling negatively and positively charged particles; spatial distribution of ionization loss as a function of the path length of channeling particles; the dechanneling length of negatively charged particles; and to clear up the role of rechanneling of the particles in the crystal. Comparison of experimental data with calculations can help to develop a description of the dynamics of motion of negatively charged particles channeling in a crystal. A better understanding of the dechanneling length properties can be useful in the production of positrons and other particles such as neutrons by an electron beam in crystals, and in the development of crystalline undulators, and at a crystal-based extraction of electron beams from a synchrotron.

physics.ins-det

Design study for a 500 MeV positron beam at the Mainz Microtron MAMI

A design study has been performed for a positron beam with an energy of 500 MeV to be realized at the applied physics area of the Mainz Microtron MAMI. Positrons will be created after pair conversion of bremsstrahlung, produced by the 855 MeV electron beam af MAMI in a tungsten converter target. From the two conceivable geometries (i) pair conversion in the bremsstrahlung converter target itself, and (ii) bremsstrahlung pair conversion in a separated lead foil, the former was considered in detail. Positrons will be energy selected within an outside open electron beam-line bending magnet, and bent back by an additional sector magnet. Magnetic focusing elements in between are designed to prepare in a well shielded positron target chamber about 6 m away from the target a beam with horizontal and vertical emittances of epsilon_v = 0.055 pi mm mrad (1 sigma), and epsilon_h = 0.12 pi mm mrad (1 sigma), respectively, for a 10 micro m thick amorphous tungsten target and negligible momentum spread. At an accepted positron band width of 1 MeV, spots are expected vertically with an angular spread of 0.064 mrad and a size of 5.0 mm (FWHM), and horizontally with an angular spread of 0.64 mrad and a size of 7.7 mm (FWHM). The positron yield amounts to 13.1 per second, 1 MeV positron energy band width, and 1 nA electron beam current.

physics.acc-ph

Electron beam studies of light collection in a scintillating counter with embedded fibers

The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light yield produced by the 855-MeV beam of the Mainz Microtron showed a strong dependence on the transverse distance from the beam position to the fibers. The observations were modeled by attributing the collection of indirect light inside of the counter and of direct light reaching a fiber to the total light yield. The light collection with fibers was compared to that of a scintillating counter without fibers. These studies were carried out within the development of plastic scintillating detectors as an active veto system for the DarkMESA electron beam-dump experiment that will search for light dark matter particles in the MeV mass range.

physics.ins-det

Investigation on radiation generated by Sub-GeV electrons in ultrashort Si and Ge bent crystals

We report on the measurements of the spectra of gamma radiation generated by 855 MeV electrons in bent silicon and germanium crystals at MAMI (MAinzer MIkrotron). The crystals were 15 μm thick along the beam direction to ensure high deflection efficiency. Their (111) crystalline planes were bent by means of a piezo-actuated mechanical holder, which allowed to remotely change the crystal curvature. In such a way it was possible to investigate the radiation emitted under planar channeling and volume reflection as a function of the curvature of the crystalline planes. We show that using volume reflection, one can produce intense gamma radiation with comparable intensity but higher angular acceptance than for channeling. We studied the trade-off between radiation intensity and angular acceptance at different values of the crystal curvature. The measurements of radiation spectra have been carried out for the first time in bent Germanium crystals. In particular, the intensity of radiation in the Ge crystal is higher than in the Si one due to the higher atomic number, which is important for the development of the X-ray and gamma radiation sources based on higher-Z deformed crystals, such as crystalline undulator.

physics.acc-ph

Time performance of a triple-GEM detector at high rate

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.

physics.ins-det

Channeling experiments at planar diamond and silicon single crystals with electrons from the Mainz Microtron MAMI

Line structures were observed for (110) planar channeling of electrons in a diamond single crystal even at a beam energy of 180 MeV. This observation motivated us to initiate dechanneling length measurements as function of the beam energy since the occupation of quantum states in the channeling potential is expected to enhance the dechanneling length. High energy loss signals, generated as a result of emission of a bremsstrahlung photon with about half the beam energy at channeling of 450 and 855 MeV electrons, were measured as function of the crystal thickness. The analysis required additional assumptions which were extracted from the numerical solution of the Fokker-Planck equation. Preliminary results for diamond are presented. In addition, we reanalyzed dechanneling length measurements at silicon single crystals performed previously at the Mainz Microtron MAMI at beam energies between 195 and 855 MeV from which we conclude that the quality of our experimental data set is not sufficient to derive definite conclusions on the dechanneling length. Our experimental results are below the predictions of the Fokker-Planck equation and somewhat above the results of simulation calculations of A. V. Korol and A. V. Solov'yov et al. on the basis of the MBN Explorer simulation package. We somehow conservatively conclude that the prediction of the asymptotic dechanneling length on the basis of the Fokker-Planck equation represents an upper limit.

physics.acc-ph

Innovative remotely-controlled bending device for thin silicon and germanium crystals

Steering of negatively charged particle beams below 1 GeV has demonstrated to be possible with thin bent silicon and germanium crystals. A newly designed mechanical holder was used for bending crystals, since it allows a remotely-controlled adjustment of crystal bending and compensation of unwanted torsion. Bent crystals were installed and tested at the MAMI Mainz MIcrotron to achieve steering of 0.855-GeV electrons at different bending radii. We report the description and characterization of the innovative bending device developed at INFN Laboratori Nazionali di Legnaro (LNL).

physics.ins-det

Broad angular anisotropy of multiple scattering in a Si crystal

We observed reduction of multiple Coulomb scattering of 855 MeV electrons within a Si crystalline plate w.r.t. an amorphous plate with the same mass thickness. The reduction owed to complete or partial suppression of the coherent part of multiple scattering in a crystal vs crystal orientation with the beam. Experimental data were collected at Mainz Mikrotron and critically compared to theoretical predictions and Monte Carlo simulations. Our results highlighted maximal 7 % reduction of the r.m.s. scattering angle at certain beam alignment with the [100] crystal axes. However, partial reduction was recorded over a wide range of alignment of the electron beam with the crystal up to 15 deg. This evidence may be relevant to refine the modelling of multiple scattering in crystals for currently used software, which is interesting for detectors in nuclear, medical, high energy physics.

physics.acc-ph

The Innovative Design of the PANDA Barrel DIRC

The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test beam campaigns at the CERN PS in 2017 and 2018 are discussed.

physics.ins-det

The Barrel DIRC detector of PANDA

The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $α_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$Δ$p/p = 4$\cdot10^{-5}$} allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between $22^\circ$ and $140^\circ$ and will achieve a pion-kaon separation of 3 standard deviations up to 3.5 GeV/$c$. Here, results of a test beam are shown for a single radiator bar coupled to a prism with $33^\circ$ opening angle, both made from synthetic fused silica read out with a photon detector array with 768 pixels.

physics.ins-det

Precision beam energy measurement by undulator radiation at MAMI

A novel interferometric method for absolute beam energy measurement is under development at MAMI. At the moment, the method is tested and optimized at an energy of 195 MeV. Despite the very small statistical uncertainty of the method, systematic effects have limited the overall accuracy. Recently, a measurement has been performed dedicated to the evaluation of these effects. This report comprises a description of the method and results of the recent data taking period.

physics.ins-det

Direct Measurement of Focusing Fields in Active Plasma Lenses

Active plasma lenses have the potential to enable broad-ranging applications of plasma-based accelerators owing to their compact design and radially symmetric kT/m-level focusing fields, facilitating beam-quality preservation and compact beam transport. We report on the direct measurement of magnetic field gradients in active plasma lenses and demonstrate their impact on the emittance of a charged particle beam. This is made possible by the use of a well-characterized electron beam with 1.4 mm mrad normalized emittance from a conventional accelerator. Field gradients of up to 823 T/m are investigated. The observed emittance evolution is supported by numerical simulations, which suggest the potential for conservation of the core beam emittance in such a plasma lens setup.

physics.acc-ph

Novel optical interferometry of synchrotron radiation for absolute electron beam energy measurements

A novel interferometric method is presented for the measurement of the absolute energy of electron beams. In the year 2016, a pioneering experiment was performed using a 195 MeV beam of the Mainz Microtron (MAMI). The experimental setup consisted of two collinear magnetic undulators as sources of coherent optical synchrotron light and a high-resolving grating monochromator. Beam energy measurements required the variation of the relative undulator distance in the decimeter range and the analysis of the intensity oscillation length in the interference spectrum. A statistical precision of 1 keV was achieved in 1 hour of data taking, while systematic uncertainties of 700 keV were present in the experiment. These developments aim for a relative precision of $10^{-5}$ in the absolute momentum calibrations of spectrometers and high-precision hypernuclear experiments. Other electron accelerators with beam energies in this regime such as the Mainz Energy Recovering Superconducting Accelerator (MESA) might benefit from this new method.

physics.ins-det