SearcharxivSearch

arXiv subjects

W. M. Chan

Publications and source records attributed to W. M. Chan.

4 recordsLinked to original sources

Signatures of a high-temperature collective electronic phase with superconductivity-like characteristics and a giant pressure effect in networks of boron-doped ultrathin carbon nanotubes

We present data consistent with a high-temperature collective electronic phase with superconductivity-like characteristics in three dimensional networks of boron doped, ultrathin carbon nanotubes (CNTs) grown inside the 5 Angstrom channels of ZSM-5 zeolite. Confinement stabilizes (2,1) CNTs that are otherwise dynamically unstable, while boron doping shifts the Fermi level towards a van Hove singularity, as supported by ab-initio calculations. The resulting CNT network exhibits multiple, mutually consistent signatures of an electronic condensate with the typical characteristics of a high temperature superconductor at ambient pressure. DC magnetization and AC susceptibility measurements reveal the onset of a Meissner response between 220 and 250K, with compacted samples achieving up to 93 percent of full diamagnetic screening. Electrical transport shows a sharp resistive transition with extrapolated Tc = 239K and vanishing resistance in optimized samples. Specific heat measurements display a reproducible anomaly at 233 to 236 K that broadens under magnetic field, consistent with strong fluctuations. Point contact spectroscopy identifies three energy gaps, including a leading gap of 30 meV whose temperature dependence follows BCS expectations for Tc = 224K, and exhibits particle-hole symmetry and Andreev reflection. Remarkably, applying pressures below 0.1 kbar enhances Tc by nearly 100K and modulates the room temperature resistance by more than three orders of magnitude, suggesting a pressure driven 1D to 3D crossover in the CNT network. These results identify boron doped ultrathin CNT networks as a promising carbon-based platform for near ambient temperature superconductivity and reveal an unusually large pressure sensitivity with potential technological relevance.

cond-mat.supr-con

Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca

We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.

hep-ex

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.

physics.ins-det

The energy calibration system for CANDLES using (n, γ) reaction

CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.

physics.ins-det