Searcharxiv⌕ Search

arXiv subjects

W. Scandale

Publications and source records attributed to W. Scandale.

26 records · Page 2Linked to original sources

Making Micro- and Nano-beams by Channeling in Micro- and Nano-structures

A particle beam of very small cross-section is useful in many accelerator applications including biological and medical ones. We show the capability of the channeling technique using a micron-sized structure on a surface of a single crystal, or using a nanotube, to produce beam of a cross-section down to 1 square micrometer (or nanometer). The channeled beam can be deflected and thus well separated in angle and space from the primary and scattered particles. Monte Carlo simulation is done to evaluate the characteristics of a channeled microbeam. Emittances down to 0.1-0.001 nanometer radian, and flux up to 1 million particles per square micron per second, can be achieved for protons and ions.

physics.acc-ph↗

Channeling of high energy beams in nanotubes

We present simulations of particle beam channeling in carbon nanotubes and evaluate the possibilities for experimental observation of channeling effect in straight and bent nanotubes at IHEP and LNF. Different particle species are considered: protons of 1.3 and 70 GeV, and positrons of 0.5 GeV. Predictions are made for the experiments, with analysis of requirements on the quality of nanosamples and resolution of the experimental set-up. Based on Monte Carlo simulations, the capabilities of nanotube channeling technique for particle beam steering are discussed.

physics.acc-ph↗

The Investigations Of Beam Extraction And Collimation At U-70 Proton Synchrotron Of IHEP By Using Short Silicon Crystals

The new results of using short (2-4mm) bent crystals for extraction and collimation of proton beam at IHEP 70 Gev proton synchrotron are reported. A broad range of energies from 6 to 65 GeV has been studied in the same crystal collimation set-up. The efficiency of extraction more than 85% and intensity more than 10E12 were obtained by using crystal with the length 2-mm and the angle 1 mrad. The new regime of extraction is applied now at the accelerator to deliver the beam for different experimental setups within the range of intensity 10E7-10E12ppp.

hep-ex↗

Crystal experiments on efficient beam extraction

Silicon crystal was channeling and extracting 70-GeV protons from the U-70 accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12 protons directed towards crystals of 2 mm length in spills of 1-2 s duration. The experimental data follow very well the prediction of Monte Carlo simulations. This success is important to devise a more efficient use of the U-70 accelerator in Protvino and provides a crucial support for implementation of crystal-assisted collimation of gold ion beam in RHIC and slow extraction from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV (scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond (scraping in the Tevatron, LHC, VLHC), can benefit from these studies.

hep-ex↗

Crystal collimation experiment on 70-GeV proton accelerator

The first proof-of-principle experiment on "crystal collimation" was performed with 70-GeV protons on IHEP accelerator. A bent crystal installed in the ring as a primary element upstream of a collimator has reduced the radiation levels downstream in the accelerator by a factor of two. The measurements agree with Monte Carlo predictions.

hep-ex↗

Progress in crystal extraction and collimation

Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow extraction and collimation of 85.3+-2.8%, at the intensities of the channeled beam on the order of 10^12 proton per spill of 2 s duration. The obtained experimental data well follows the theory predictions. We compare the measurements against theory and outline the theoretical potential for further improvement in the efficiency of the technique. This success is important for the efficient use of IHEP accelerator and for implementation of crystal-assisted collimation at RHIC and slow extraction from AGS onto E952, now in preparation. Future applications, spanning in the energy from order of 1 GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from these studies.

hep-ex↗

New projects of crystal extraction at IHEP 70-GeV accelerator

Using channeling in a 5-mm crystal with bending angle of 0.65 mrad, a record high efficiency, over 60%, of particle extraction from accelerator was achieved. The extracted beam intensity was up to 5.2*10^11 protons per spill of 0.5 s duration. Also, the first proof-of-principle experiment on 'crystal collimation' was performed where crystal - serving as a scraper - has reduced the radiation level in the accelerator by a factor of two. The measurements agree with Monte Carlo predictions.

hep-ex↗

Application of bent crystals at IHEP 70-GeV accelerator to enhance the efficiency of its usage

Bent crystal was extracting 70-GeV protons with average intensity 4*10^11 (as measured in external beamline) per spill of 1.6 s duration, in parallel to the simultaneous work of two internal targets in the accelerator ring. An additional crystal, placed in the external beamline, was deflecting a small part of the extracted beam with intensity 10^7 protons toward another physics experiment. Crystal-extracted beam had a typical size of 4 mm by 4 mm fwhm at the end of the external beamline. Measurements for the extraction efficiency and other characteristics at the simultaneous work of four experimental set-ups are presented. With crystal working in the above-said regime during one month, no degradation of channeling was observed. The studies of extraction efficiency have been continued with new crystals.

hep-ex↗