SearcharxivSearch

arXiv subjects

W. Shen

Publications and source records attributed to W. Shen.

At least 19 recordsLinked to original sources

Technical design of the phase I Mu3e experiment

The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ\rightarrow eee$ at branching fractions above $10^{-16}$. A first phase of the experiment using an existing beamline at the Paul Scherrer Institute (PSI) is designed to reach a single event sensitivity of $2\cdot 10^{-15}$. We present an overview of all aspects of the technical design and expected performance of the phase~I Mu3e detector. The high rate of up to $10^{8}$ muon decays per second and the low momenta of the decay electrons and positrons pose a unique set of challenges, which we tackle using an ultra thin tracking detector based on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements.

physics.ins-det

Traveling wave solutions for two species competitive chemotaxis systems

In this paper, we consider two species chemotaxis systems with Lotka-Volterra competition reaction terms. Under appropriate conditions on the parameters in such a system, we establish the existence of traveling wave solutions of the system connecting two spatially homogeneous equilibrium solutions with wave speed greater than some critical number c*. We also show the non-existence of such traveling waves with speed less than some critical number c*_0, which is independent of the chemotaxis. Moreover, under suitable hypotheses on the coefficients of the reaction terms, we obtain explicit range for the chemotaxis sensitivity coefficients ensuring c*= c*_0, which implies that the minimum wave speed exists and is not affected by the chemoattractant.

math.AP

SENSE: A comparison of photon detection efficiency and optical crosstalk of various SiPM devices

This paper describes a comparison of photon detection efficiency and optical crosstalk measurements performed by three partners: Geneva University, Catania Observatory and Nagoya University. The measurements were compared for three different SiPM devices with different active areas: from 9 $mm^2$ up to 93.6 $mm^2$ produced by Hamamatsu. The objective of this work is to establish the measurements and analysis procedures for calculating the main SiPM parameters and their precision. This work was done in the scope of SENSE project which aims to build roadmap for the last developments in field of sensors for low light level detection.

physics.ins-det

On traveling wave solutions in full parabolic Keller-Segel chemotaxis systems with logistic source

This paper is concerned with traveling wave solutions of the following full parabolic Keller-Segel chemotaxis system with logistic source, \begin{equation} \begin{cases} u_t=Δu -χ\nabla\cdot(u\nabla v)+u(a-bu),\quad x\in\mathbb{R}^N \cr τv_t=Δv-λv +μu,\quad x\in \mathbb{R}^N, \end{cases}(1) \end{equation} where $χ, μ,λ,a,$ and $b$ are positive numbers, and $τ\ge 0$. Among others, it is proved that if $b>2χμ$ and $τ\geq \frac{1}{2}(1-\fracλ{a})_{+} ,$ then for every $c\ge 2\sqrt{a}$, (1) has a traveling wave solution $(u,v)(t,x)=(U^{τ,c}(x\cdotξ-ct),V^{τ,c}(x\cdotξ-ct))$ ($\forall\, ξ\in\mathbb{R}^N$) connecting the two constant steady states $(0,0)$ and $(\frac{a}{b},\fracμλ\frac{a}{b})$, and there is no such solutions with speed $c$ less than $2\sqrt{a}$, which improves considerably the results established in \cite{SaSh3}, and shows that (1) has a minimal wave speed $c_0^*=2\sqrt a$, which is independent of the chemotaxis.

math.AP

Parabolic-elliptic chemotaxis model with space-time dependent logistic sources on $\mathbb{R}^N$. III. Transition fronts

The current work is the third of a series of three papers devoted to the study of asymptotic dynamics in the space-time dependent logistic source chemotaxis system, $$ \begin{cases} \partial_tu=Δu-χ\nabla\cdot(u\nabla v)+u(a(x,t)-b(x,t)u),\quad x\in R^N,\cr 0=Δv-λv+μu ,\quad x\in R^N, \end{cases} (0.1) $$ where $N\ge 1$ is a positive integer, $χ, λ$ and $μ$ are positive constants, the functions $a(x,t)$ and $b(x,t)$ are positive and bounded. In the first of the series, we studied the phenomena of persistence, and the asymptotic spreading for solutions. In the second of the series, we investigate the existence, uniqueness and stability of strictly positive entire solutions. In the current part of the series, we discuss the existence of transition front solutions of (0.1) connecting $(0,0)$ and $(u^*(t),v^*(t))$ in the case of space homogeneous logistic source. We show that for every $χ>0$ with $χμ\big(1+\frac{\sup_{t\in R}a(t)}{\inf_{t\in R}a(t)}\big)<\inf_{t\in R}b(t)$, there is a positive constant $c^{*}_χ$ such that for every $\underline{c}>c^{*}_χ$ and every unit vector $ξ$, (0.1) has a transition front solution of the form $(u(x,t),v(x,t))=(U(x\cdotξ-C(t),t),V(x\cdotξ-C(t),t))$ satisfying that $C'(t)=\frac{a(t)+κ^2}κ$ for some number $κ>0$, $\liminf_{t-s\to\infty}\frac{C(t)-C(s)}{t-s}=\underline{c}$, and$$\lim_{x\to-\infty}\sup_{t\in R}|U(x,t)-u^*(t)|=0 \quad \text{and}\quad \lim_{x\to\infty}\sup_{t\in R}|\frac{U(x,t)}{e^{-κx}}-1|=0.$$Furthermore, we prove that there is no transition front solution $(u(x,t),v(x,t))=(U(x\cdotξ-C(t),t),V(x\cdotξ-C(t),t))$ of (0.1) connecting $(0,0)$ and $(u^*(t),v^*(t))$ with least mean speed less than $2\sqrt{\underline{a}}$, where $\underline{a}=\liminf_{t-s\to\infty}\frac{1}{t-s}\int_{s}^{t}a(τ)dτ$.

math.AP

Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter

The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.

physics.ins-det

Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.

physics.ins-det

Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter

Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.

physics.ins-det

The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.

physics.ins-det

Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

physics.ins-det

Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.

physics.ins-det

Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL

Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid. A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.

physics.ins-det

Exact solution for Bloch oscillations of a simple charge-density-wave insulator

Charge-density-wave systems have a static modulation of the electronic charge at low temperatures when they enter an ordered state. While they have been studied for decades in equilibrium, it is only recently that they have been examined in nonequilibrium with time-resolved studies. Here, we present the exact solution for the nonequilibrium response of electrons (in the simplest model for a charge density wave) when the system is placed under a strong DC electric field. This allows us to examine the formation of driven Bloch oscillations and how the presence of a current modifies the nonequilibrium density of states.

cond-mat.str-el

Nonequilibrium "melting" of a charge density wave insulator via an ultrafast laser pulse

We employ an exact solution of the simplest model for pump-probe time-resolved photoemission spectroscopy in charge-density-wave systems to show how, in nonequilibrium the gap in the density of states disappears while the charge density remains modulated, and then the gap reforms after the pulse has passed. This nonequilibrium scenario qualitatively describes the common short-time experimental features in TaS2 and TbTe3 indicating a quasiuniversality for nonequilibrium "melting" with qualitative features that can be easily understood within a simple picture.

cond-mat.str-el

Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter

We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.

physics.ins-det

Research Proposal for an Experiment to Search for the Decay μ -> eee

We propose an experiment (Mu3e) to search for the lepton flavour violating decay mu+ -> e+e-e+. We aim for an ultimate sensitivity of one in 10^16 mu-decays, four orders of magnitude better than previous searches. This sensitivity is made possible by exploiting modern silicon pixel detectors providing high spatial resolution and hodoscopes using scintillating fibres and tiles providing precise timing information at high particle rates.

physics.ins-det

Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques

The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.

physics.ins-det

Electromagnetic response of a highly granular hadronic calorimeter

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.

physics.ins-det