SearcharxivSearch

arXiv subjects

W. Skulski

Publications and source records attributed to W. Skulski.

17 recordsLinked to original sources

FPGA-based Trigger System for the LUX Dark Matter Experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils resulting from interactions with dark matter particles. Signals from the detector are processed with an FPGA-based digital trigger system that analyzes the incoming data in real-time, with just a few microsecond latency. The system enables first pass selection of events of interest based on their pulse shape characteristics and 3D localization of the interactions. It has been shown to be >99% efficient in triggering on S2 signals induced by only few extracted liquid electrons. It is continuously and reliably operating since its full underground deployment in early 2013. This document is an overview of the systems capabilities, its inner workings, and its performance.

physics.ins-det

Participant and spectator scaling of spectator fragments in Au+Au and Cu+Cu collisions at sqrt(sNN) = 19.6 and 22.4 GeV

Spectator fragments resulting from relativistic heavy ion collisions, consisting of single protons and neutrons along with groups of stable nuclear fragments up to Nitrogen (Z=7), are measured in PHOBOS. These fragments are observed in Au+Au (sqrt(sNN)=19.6 GeV) and Cu+Cu (22.4 GeV) collisions at high pseudorapidity ($η$). The dominant multiply-charged fragment is the tightly bound Helium ($α$), with Lithium, Beryllium, and Boron all clearly seen as a function of collision centrality and pseudorapidity. We observe that in Cu+Cu collisions, it becomes much more favorable for the $α$ fragments to be released than Lithium. The yields of fragments approximately scale with the number of spectator nucleons, independent of the colliding ion. The shapes of the pseudorapidity distributions of fragments indicate that the average deflection of the fragments away from the beam direction increases for more central collisions. A detailed comparison of the shapes for $α$ and Lithium fragments indicates that the centrality dependence of the deflections favors a scaling with the number of participants in the collision.

nucl-ex

Nucleon-Gold Collisions at 200 AGeV Using Tagged d+Au Interactions in PHOBOS

Forward calorimetry in the PHOBOS detector has been used to study charged hadron production in d+Au, p+Au and n+Au collisions at sqrt(s_nn) = 200 GeV. The forward proton calorimeter detectors are described and a procedure for determining collision centrality with these detectors is detailed. The deposition of energy by deuteron spectator nucleons in the forward calorimeters is used to identify p+Au and n+Au collisions in the data. A weighted combination of the yield of p+Au and n+Au is constructed to build a reference for Au+Au collisions that better matches the isospin composition of the gold nucleus. The p_T and centrality dependence of the yield of this improved reference system is found to match that of d+Au. The shape of the charged particle transverse momentum distribution is observed to extrapolate smoothly from pbar+p to central d+Au as a function of the charged particle pseudorapidity density. The asymmetry of positively- and negatively-charged hadron production in p+Au is compared to that of n+Au. No significant asymmetry is observed at mid-rapidity. These studies augment recent results from experiments at the LHC and RHIC facilities to give a more complete description of particle production in p+A and d+A collisions, essential for the understanding the medium produced in high energy nucleus-nucleus collisions.

nucl-ex

First results from the LUX dark matter experiment at the Sanford Underground Research Facility

The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.

astro-ph.CO

An Ultra-Low Background PMT for Liquid Xenon Detectors

Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.

physics.ins-det

Technical Results from the Surface Run of the LUX Dark Matter Experiment

We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.

astro-ph.IM

The LUX Prototype Detector: Heat Exchanger Development

The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.

physics.ins-det

The Large Underground Xenon (LUX) Experiment

The Large Underground Xenon (LUX) collaboration has designed and constructed a dual-phase xenon detector, in order to conduct a search for Weakly Interacting Massive Particles(WIMPs), a leading dark matter candidate. The goal of the LUX detector is to clearly detect (or exclude) WIMPS with a spin independent cross section per nucleon of $2\times 10^{-46}$ cm$^{2}$, equivalent to $\sim$1 event/100 kg/month in the inner 100-kg fiducial volume (FV) of the 370-kg detector. The overall background goals are set to have $<$1 background events characterized as possible WIMPs in the FV in 300 days of running. This paper describes the design and construction of the LUX detector.

physics.ins-det

Radio-assay of Titanium samples for the LUX Experiment

We report on the screening of samples of titanium metal for their radio-purity. The screening process described in this work led to the selection of materials used in the construction of the cryostats for the Large Underground Xenon (LUX) dark matter experiment. Our measurements establish titanium as a highly desirable material for low background experiments searching for rare events. The sample with the lowest total long-lived activity was measured to contain <0.25 mBq/kg of U-238, <0.2 mBq/kg of Th-232, and <1.2 mBq/kg of K-40. Measurements of several samples also indicated the presence of short-lived (84 day half life) Sc-46, likely produced cosmogenically via muon initiated (n,p) reactions.

physics.ins-det

LUXSim: A Component-Centric Approach to Low-Background Simulations

Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage. * Corresponding author, kareem@llnl.gov

physics.data-an

After LUX: The LZ Program

The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.

astro-ph.IM

Data Acquisition and Readout System for the LUX Dark Matter Experiment

LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.

astro-ph.IM

Phobos results on charged particle multiplicity and pseudorapidity distributions in Au+Au, Cu+Cu, d+Au, and p+p collisions at ultra-relativistic energies

Pseudorapidity distributions of charged particles emitted in $Au+Au$, $Cu+Cu$, $d+Au$, and $p+p$ collisions over a wide energy range have been measured using the PHOBOS detector at RHIC. The centrality dependence of both the charged particle distributions and the multiplicity at midrapidity were measured. Pseudorapidity distributions of charged particles emitted with $|η|<5.4$, which account for between 95% and 99% of the total charged-particle emission associated with collision participants, are presented for different collision centralities. Both the midrapidity density, $dN_{ch}/dη$, and the total charged-particle multiplicity, $N_{ch}$, are found to factorize into a product of independent functions of collision energy, $\sqrt{s_{_{NN}}}$, and centrality given in terms of the number of nucleons participating in the collision, $N_{part}$. The total charged particle multiplicity, observed in these experiments and those at lower energies, assumes a linear dependence of $(\ln s_{_{NN}})^2$ over the full range of collision energy of $\sqrt{s_{_{NN}}}$=2.7-200 GeV.

nucl-ex

Status of the LUX Dark Matter Search

The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.

astro-ph.CO

R & D for Future Zeplin

We propose a new concept for a very low background multi-ton liquid xenon Dark Matter experiment. The detector consists of two concentric spheres and a charge readout device in the centre. Xenon between the two spheres forms a self-shield and veto device. The inner surface of the central sphere is coated with CsI to form an internal photocathode with minimum of 2πcoverage for any event in the active volume. Photoelectrons from the CsI photocathode drift toward the charge readout micro-structure in the centre of the detector. Both scintillation and ionisation are measured simultaneously for background rejection and 3-D event mapping. In addition to external shielding, the low background is achieved by eliminating PMTs and by using low radioactivity pure materials throughout the detector. We present detailed calculations of the charge readout system and design details. The detector is expected to probe the full SUSY parameter space.

astro-ph

Statistical Interpretation of Joint Multiplicity Distributions of Neutrons and Charged Particles

Experimental joint multiplicity distributions of neutrons and charged particles emitted in complex nuclear reactions provide an important test of theoretical models. The method is applied to test three different theoretical models of nuclear multi-fragmentation, two of which fail the test. The measurement of neutrons is decisive in distinguishing between the Berlin and Copenhagen models of nuclear multi-fragmentation and challenges the interpretation of pseudo- Arrhenius plots. Statistical-model evaporation calculations with GEMINI give a good reproduction first and second moments of the experimental multiplicity correlations.

nucl-ex

Probing the Concept of Statistical Independence of Intermediate-Mass Fragment Production in Heavy-Ion Collisions

It is found that the total IMF-transverse-energy (E_t) spectra in multi-IMF events are well represented by synthetic spectra obtained by folding of the single-IMF spectrum. Using the experimental IMF multiplicity distribution, the observed trends in the IMF multiplicity distribution for fixed values of E_t are reproduced. The synthetic distributions show binomial reducibility and Arrhenius-like scaling, similar to that reported in the literature. Similar results are obtained when the above folding-type synthesis is replaced with one based on mixing events with different IMF multiplicities. For statistically independent IMF emission, the observed binomial reducibility and Arrhenius-type scaling are merely reflections of the shape of the single-IMF transverse-energy spectrum. Hence, a valid interpretation of IMF distributions in terms of a particular production scenario has to explain independently the observed shape of the single-IMF E_t spectrum.

nucl-ex