SearcharxivSearch

arXiv subjects

W. T. Kim

Publications and source records attributed to W. T. Kim.

11 recordsLinked to original sources

A study of neutrinoless double electron capture in $^{40}$Ca from the AMoRE experiment

The search for neutrinoless double electron capture ($0\nu\mathrm{2EC}$) provides a sensitive probe of lepton-number violation and the Majorana nature of neutrinos. We investigate the $0\nu\mathrm{2EC}$ decay of $^{40}$Ca using cryogenic detectors equipped with metallic magnetic calorimeters in the AMoRE-I experiment. The analysis is based on a physics dataset corresponding to a total exposure of 7.32 kg$\cdot$yr from thirteen $^{40}$Ca$^{100}$MoO$_4$ crystals. No significant excess is observed, and a lower limit on the half-life is obtained as $T^{0\nu}_{1/2} > 1.7 \times 10^{22}$ yr at 90$\%$ confidence level. An improved sensitivity is expected for the upcoming AMoRE-II experiment. These results demonstrate the potential of CaMoO$_4$ detectors to explore rare decay processes beyond the primary $^{100}$Mo $0\nu\beta\beta$ search program.

nucl-ex

LiFE-SNS: LiF Experiment for keV-scale Sterile Neutrino Search

The LiF Experiment for keV-scale Sterile Neutrino Search (LiFE-SNS) aims to probe sterile neutrinos through precision measurements of the tritium $β$ spectrum. Tritium nuclei are produced and embedded in LiF crystals via the ${}^{6}\mathrm{Li}(n,α){}^{3}\mathrm{H}$ reaction, allowing thermal calorimetric detection of $β$ decays with magnetic microcalorimeters (MMCs) operated at millikelvin temperatures. We present the detector configuration, background studies, and calibration method, including modeling of position-dependent response and characterization of detector nonlinearity. We also discuss potential sources of systematic uncertainty relevant to the sterile-neutrino search. While the first phase of LiFE-SNS has been completed, this paper focuses on calibration and detector characterization. The achieved performance enables precision $β$-spectrum measurements, and projected sensitivities indicate competitive reach in the keV mass region.

hep-ex

Improved limit on neutrinoless double beta decay of $^{100}$Mo from AMoRE-I

AMoRE searches for the signature of neutrinoless double beta decay of $^{100}$Mo with a 100 kg sample of enriched $^{100}$Mo. Scintillating molybdate crystals coupled with a metallic magnetic calorimeter operate at milli-Kelvin temperatures to measure the energy of electrons emitted in the decay. As a demonstration of the full-scale AMoRE, we conducted AMoRE-I, a pre-experiment with 18 molybdate crystals, at the Yangyang Underground Laboratory for over two years. The exposure was 8.02 kg$\cdot$year (or 3.89 kg$_{\mathrm{^{100}Mo}}\cdot$year) and the total background rate near the Q-value was 0.025 $\pm$ 0.002 counts/keV/kg/year. We observed no indication of $0νββ$ decay and report a new lower limit of the half-life of $^{100}$Mo $0νββ$ decay as $ T^{0ν}_{1/2}>2.9\times10^{24}~\mathrm{yr}$ at 90\% confidence level. The effective Majorana mass limit range is $m_{ββ}<$(210--610) meV using nuclear matrix elements estimated in the framework of different models, including the recent shell model calculations.

nucl-ex

Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II

The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.

physics.ins-det

Projected background and sensitivity of AMoRE-II

AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.

physics.ins-det

Background study of the AMoRE-pilot experiment

We report a study on the background of the Advanced Molybdenum-Based Rare process Experiment (AMoRE), a search for neutrinoless double beta decay (\znbb) of $^{100}$Mo. The pilot stage of the experiment was conducted using $\sim$1.9 kg of \CAMOO~ crystals at the Yangyang Underground Laboratory, South Korea, from 2015 to 2018. We compared the measured $β/γ$ energy spectra in three experimental configurations with the results of Monte Carlo simulations and identified the background sources in each configuration. We replaced several detector components and enhanced the neutron shielding to lower the background level between configurations. A limit on the half-life of $0νββ$ decay of $^{100}$Mo was found at $T_{1/2}^{0ν} \ge 3.0\times 10^{23}$ years at 90\% confidence level, based on the measured background and its modeling. Further reduction of the background rate in the AMoRE-I and AMoRE-II are discussed.

nucl-ex

Alpha backgrounds in the AMoRE-Pilot experiment

The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.

physics.ins-det

Status and performance of the AMoRE-I experiment on neutrinoless double beta decay

AMoRE is an international project to search for the neutrinoless double beta decay of $^{100}$Mo using a detection technology consisting of magnetic microcalorimeters (MMCs) and molybdenum-based scintillating crystals. Data collection has begun for the current AMORE-I phase of the project, an upgrade from the previous pilot phase. AMoRE-I employs thirteen $^\mathrm{48depl.}$Ca$^{100}$MoO$_4$ crystals and five Li$_2$$^{100}$MoO$_4$ crystals for a total crystal mass of 6.2 kg. Each detector module contains a scintillating crystal with two MMC channels for heat and light detection. We report the present status of the experiment and the performance of the detector modules.

physics.ins-det

A feasibility study of extruded plastic scintillator embedding WLS fiber for AMoRE-II muon veto

AMoRE-II is the second phase of the Advanced Molybdenum-based Rare process Experiment aiming to search for the neutrino-less double beta decay of 100Mo isotopes using ~ 200 kg of molybdenum-containing cryogenic detectors. The AMoRE-II needs to keep the background level below 10-5 counts/keV/kg/year with various methods to maximize the sensitivity. One of the methods is to have the experiment be carried out deep underground free from the cosmic ray backgrounds. The AMoRE-II will run at Yemilab with ~ 1,000 m depth. However, even in such a deep underground environment, there are still survived cosmic muons, which can affect the measurement and should be excluded as much as possible. A muon veto detector is necessary to reject muon-induced particles coming to the inner detector where the molybdate cryogenic detectors are located. We have studied the possibility of using an extruded plastic scintillator and wavelength shifting fiber together with SiPM as a muon veto system. We found that the best configuration is two layers of plastic scintillators (PSs, 150 cm x 25 cm x 1.2 cm) with two WLS fibers per groove, which could separate radiogenic gammas well with muon detection efficiency above 99.4% along the length of the PS. Based on the expected flux from a prototype measurement at a 700 m deep underground, we found that the dead time of the muon veto system for AMoRE-II at the Yemilab with a 1 ms veto window is 0.6% of whole muon events.

physics.ins-det

Measurement of the Gamma Ray Background in the Davis Cavern at the Sanford Underground Research Facility

Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from $γ$-rays emitted by $^{40}$K and the $^{238}$U and $^{232}$Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ $γ$-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of $1.9\pm0.4$~$γ~$cm$^{-2}$s$^{-1}$. The resulting activity in the walls of the cavern can be characterised as $220\pm60$~Bq/kg of $^{40}$K, $29\pm15$~Bq/kg of $^{238}$U, and $13\pm3$~Bq/kg of $^{232}$Th.

physics.ins-det

First Results from the AMoRE-Pilot neutrinoless double beta decay experiment

The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.

hep-ex