SearcharxivSearch

arXiv subjects

Walter Hartung

Publications and source records attributed to Walter Hartung.

4 recordsLinked to original sources

The Ponderomotive Effects of Narrow-band, Superconducting Resonators in Open and Closed Loop

In this work, we present measurements of ponderomotive instabilities in narrow-band, coaxial resonators in open and closed control loop systems. We show an analytical scheme we will use in future studies to examine the dependency of open loop stability on mechanical parameters. Analytical and simulation models are used to predict the onset of the oscillatory instability in half wave resonators with active disturbance rejection control for amplitude and phase stabilization. We demonstrate that for high amplitude controller bandwidths, ponderomotive oscillations can couple with the controller frequency response via higher harmonics and lower the threshold for the oscillatory instability. We reaffirm the superiority of in-phase/quadrature $(I/Q)$ component control in regards to preventing the oscillatory instability, and show how the phase controller can amplify the crosstalk of disturbances in amplitude and phase control. In cases with large disturbances, this effect can lead to instabilities not present in $I/Q$ control.

physics.acc-ph

Impact of heat treatments on the performance of low-frequency superconducting quarter-wave resonators at 4.3 K

We applied heat treatments to 80.5 MHz quarter-wave resonators made from bulk niobium and prepared with buffered chemical polishing BCP. We evaluated their performance at 4.3 K. We found that a 48 hour, 120 C bake-out ("low-temperature bake out") reduces the surface resistance by a factor of 2 to 3, stemming from a reduction in the Bardeen-Cooper-Schrieffer contribution, consistent with previous findings. This decrease leads to a 38% decrease on average in the medium-field Q-slope when compared to cavities which had only BCP. Mechanisms for the change in quality factor with low-temperature baking have been explored. We observed no improvement in cavity performance after a 3-hour bake-out at 350 C ("medium-temperature bake out"), in contrast to observations for higher-frequency cavities.

physics.acc-ph

Report on first plasma processing trial for a FRIB quarter-wave resonator cryomodule

Plasma processing has been shown to help mitigate degradation of the performance of superconducting radio-frequency cavities, providing an alternative to removal of cryomodules from the accelerator for refurbishment. Studies of plasma processing for quarter-wave resonators (QWRs) and half-wave resonators (HWRs) are underway at the Facility for Rare Isotope Beams (FRIB), where a total of 324 such resonators are presently in operation. Plasma processing tests were done on several QWRs using the fundamental power coupler (FPC) to drive the plasma, with promising results. Driving the plasma with a higher-order mode allows for less mismatch at the FPC and higher plasma density. The first plasma processing trial for FRIB QWRs in a cryomodule was conducted in January 2024. Cold tests of the cryomodule showed a significant reduction in field emission X-rays after plasma processing.

physics.acc-ph

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (Q0) of >= 2E10 at an accelerating gradient (Ea) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing (BCP). First trials on electropolishing (EP) and post-EP low temperature baking (LTB) of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but Q0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of Q0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the ``global'' magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a ``uniform cool-down'' (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the Q0, but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching Q0 = 2.8E10 at Ea = 12 MV/m.

physics.acc-ph