SearcharxivSearch

arXiv subjects

Walter J. Curran

Publications and source records attributed to Walter J. Curran.

14 recordsLinked to original sources

Artificial Intelligence in Tumor Subregion Analysis Based on Medical Imaging: A Review

Medical imaging is widely used in cancer diagnosis and treatment, and artificial intelligence (AI) has achieved tremendous success in various tasks of medical image analysis. This paper reviews AI-based tumor subregion analysis in medical imaging. We summarize the latest AI-based methods for tumor subregion analysis and their applications. Specifically, we categorize the AI-based methods by training strategy: supervised and unsupervised. A detailed review of each category is presented, highlighting important contributions and achievements. Specific challenges and potential AI applications in tumor subregion analysis are discussed.

eess.IV

Generative Adversarial Network for Image Synthesis

This chapter reviews recent developments of generative adversarial networks (GAN)-based methods for medical and biomedical image synthesis tasks. These methods are classified into conditional GAN and Cycle-GAN according to the network architecture designs. For each category, a literature survey is given, which covers discussions of the network architecture designs, highlights important contributions and identifies specific challenges.

physics.med-ph

Synthetic MRI-aided Head-and-Neck Organs-at-Risk Auto-Delineation for CBCT-guided Adaptive Radiotherapy

Purpose: Organ-at-risk (OAR) delineation is a key step for cone-beam CT (CBCT) based adaptive radiotherapy planning that can be a time-consuming, labor-intensive, and subject-to-variability process. We aim to develop a fully automated approach aided by synthetic MRI for rapid and accurate CBCT multi-organ contouring in head-and-neck (HN) cancer patients. MRI has superb soft-tissue contrasts, while CBCT offers bony-structure contrasts. Using the complementary information provided by MRI and CBCT is expected to enable accurate multi-organ segmentation in HN cancer patients. In our proposed method, MR images are firstly synthesized using a pre-trained cycle-consistent generative adversarial network given CBCT. The features of CBCT and synthetic MRI are then extracted using dual pyramid networks for final delineation of organs. CBCT images and their corresponding manual contours were used as pairs to train and test the proposed model. Quantitative metrics including Dice similarity coefficient (DSC) were used to evaluate the proposed method. The proposed method was evaluated on a cohort of 65 HN cancer patients. CBCT images were collected from those patients who received proton therapy. Overall, DSC values of 0.87, 0.79/0.79, 0.89/0.89, 0.90, 0.75/0.77, 0.86, 0.66, 0.78/0.77, 0.96, 0.89/0.89, 0.832, and 0.84 for commonly used OARs for treatment planning including brain stem, left/right cochlea, left/right eye, larynx, left/right lens, mandible, optic chiasm, left/right optic nerve, oral cavity, left/right parotid, pharynx, and spinal cord, respectively, were achieved. In this study, we developed a synthetic MRI-aided HN CBCT auto-segmentation method based on deep learning. It provides a rapid and accurate OAR auto-delineation approach, which can be used for adaptive radiation therapy.

physics.med-ph

Knowledge-based Radiation Treatment Planning: A Data-driven Method Survey

This paper surveys the data-driven dose prediction approaches introduced for knowledge-based planning (KBP) in the last decade. These methods were classified into two major categories according to their methods and techniques of utilizing previous knowledge: traditional KBP methods and deep-learning-based methods. Previous studies that required geometric or anatomical features to either find the best matched case(s) from repository of previously delivered treatment plans or build prediction models were included in traditional methods category, whereas deep-learning-based methods included studies that trained neural networks to make dose prediction. A comprehensive review of each category is presented, highlighting key parameters, methods, and their outlooks in terms of dose prediction over the years. We separated the cited works according to the framework and cancer site in each category. Finally, we briefly discuss the performance of both traditional KBP methods and deep-learning-based methods, and future trends of both data-driven KBP approaches.

physics.med-ph

Learning-Based Synthetic Dual Energy CT Imaging from Single Energy CT for Stopping Power Ratio Calculation in Proton Radiation Therapy

Purpose: Dual-energy CT (DECT) has been shown to derive stopping power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemented as SECT in proton radiation therapy simulation. This work presents a learning-based method to synthetize DECT images from SECT for proton radiation therapy. Methods: The proposed method uses a residual attention generative adversarial network. Residual blocks with attention gates were used to force the model focus on the difference between DECT maps and SECT images. To evaluate the accuracy of the method, we retrospectively investigated 20 head-and-neck cancer patients with both DECT and SECT scans available. The high and low energy CT images acquired from DECT acted as learning targets in the training process for SECT datasets and were evaluated against results from the proposed method using a leave-one-out cross-validation strategy. To evaluate our method in the context of a practical application, we generated SPR maps from sDECT using physics-based dual-energy stoichiometric method and compared the maps to those generated from DECT. Results: The synthesized DECT images showed an average mean absolute error around 30 Hounsfield Unit (HU) across the whole-body volume. The corresponding SPR maps generated from synthetic DECT showed an average normalized mean square error of about 1% with reduced noise level and artifacts than those from original DECT. Conclusions: The accuracy of the synthesized DECT image by our machine-learning-based method was evaluated on head and neck patient, and potential feasibility for proton treatment planning and dose calculation was shown by generating SPR map using the synthesized DECT.

physics.med-ph

Deep learning-based Real-time Volumetric Imaging for Lung Stereotactic Body Radiation Therapy: A Proof of Concept Study

Due to the inter- and intra- variation of respiratory motion, it is highly desired to provide real-time volumetric images during the treatment delivery of lung stereotactic body radiation therapy (SBRT) for accurate and active motion management. In this proof-of-concept study, we propose a novel generative adversarial network integrated with perceptual supervision to derive instantaneous volumetric images from a single 2D projection. Our proposed network, named TransNet, consists of three modules, i.e., encoding, transformation and decoding modules. Rather than only using image distance loss between the generated 3D images and the ground truth 3D CT images to supervise the network, perceptual loss in feature space is integrated into loss function to force the TransNet to yield accurate lung boundary. Adversarial supervision is also used to improve the realism of generated 3D images. We conducted a simulation study on 20 patient cases, who had received lung SBRT treatments in our institution and undergone 4D-CT simulation, and evaluated the efficacy and consistency of our method for four different projection angles, i.e., 0, 30, 60 and 90 degree. For each 3D CT image set of a breathing phase, we simulated its 2D projections at these angles.Then for each projection angle, a patient's 3D CT images of 9 phases and the corresponding 2D projection data were used for training, with the remaining phase used for testing. The mean absolute error, normalized MAE, peak signal-to-noise ratio and structural similarity index metric achieved by our method are 99.3 HU, 0.032, 23.4 dB and 0.949, respectively. These results demonstrate the feasibility and efficacy of our 2D-to-3D method for lung cancer patients, which provides a potential solution for in-treatment real-time on-board volumetric imaging for accurate dose delivery to ensure the effectiveness of lung SBRT treatment.

physics.med-ph

Intensity Non-uniformity Correction in MR Imaging Using Residual Cycle Generative Adversarial Network

Purpose: Correcting or reducing the effects of voxel intensity non-uniformity (INU) within a given tissue type is a crucial issue for quantitative MRI image analysis in daily clinical practice. In this study, we present a deep learning-based approach for MRI image INU correction. Method: We developed a residual cycle generative adversarial network (res-cycle GAN), which integrates the residual block concept into a cycle-consistent GAN (cycle-GAN). In cycle-GAN, an inverse transformation was implemented between the INU uncorrected and corrected MRI images to constrain the model through forcing the calculation of both an INU corrected MRI and a synthetic corrected MRI. A fully convolution neural network integrating residual blocks was applied in the generator of cycle-GAN to enhance end-to-end raw MRI to INU corrected MRI transformation. A cohort of 30 abdominal patients with T1-weighted MR INU images and their corrections with a clinically established and commonly used method, namely, N4ITK were used as a pair to evaluate the proposed res-cycle GAN based INU correction algorithm. Quantitatively comparisons were made among the proposed method and other approaches. Result: Our res-cycle GAN based method achieved higher accuracy and better tissue uniformity compared to the other algorithms. Moreover, once the model is well trained, our approach can automatically generate the corrected MR images in a few minutes, eliminating the need for manual setting of parameters. Conclusion: In this study, a deep learning based automatic INU correction method in MRI, namely, res-cycle GAN has been investigated. The results show that learning based methods can achieve promising accuracy, while highly speeding up the correction through avoiding the unintuitive parameter tuning process in N4ITK correction.

physics.med-ph

Medical Imaging Synthesis using Deep Learning and its Clinical Applications: A Review

This paper reviewed the deep learning-based studies for medical imaging synthesis and its clinical application. Specifically, we summarized the recent developments of deep learning-based methods in inter- and intra-modality image synthesis by listing and highlighting the proposed methods, study designs and reported performances with related clinical applications on representative studies. The challenges among the reviewed studies were summarized in the discussion part.

physics.med-ph

Learning-Based Stopping Power Mapping on Dual Energy CT for Proton Radiation Therapy

Purpose: Dual-energy CT (DECT) has been used to derive relative stopping power (RSP) map by obtaining the energy dependence of photon interactions. The DECT-derived RSP maps could potentially be compromised by image noise levels and the severity of artifacts when using physics-based mapping techniques, which would affect subsequent clinical applications. This work presents a noise-robust learning-based method to predict RSP maps from DECT for proton radiation therapy. Methods: The proposed method uses a residual attention cycle-consistent generative adversarial (CycleGAN) network. CycleGAN were used to let the DECT-to-RSP mapping be close to a one-to-one mapping by introducing an inverse RSP-to-DECT mapping. We retrospectively investigated 20 head-and-neck cancer patients with DECT scans in proton radiation therapy simulation. Ground truth RSP values were assigned by calculation based on chemical compositions, and acted as learning targets in the training process for DECT datasets, and were evaluated against results from the proposed method using a leave-one-out cross-validation strategy. Results: The predicted RSP maps showed an average normalized mean square error (NMSE) of 2.83% across the whole body volume, and average mean error (ME) less than 3% in all volumes of interest (VOIs). With additional simulated noise added in DECT datasets, the proposed method still maintained a comparable performance, while the physics-based stoichiometric method suffered degraded inaccuracy from increased noise level. The average differences in DVH metrics for clinical target volumes (CTVs) were less than 0.2 Gy for D95% and Dmax with no statistical significance. Conclusion: These results strongly indicate the high accuracy of RSP maps predicted by our machine-learning-based method and show its potential feasibility for proton treatment planning and dose calculation.

physics.med-ph

Deep Learning in Multi-organ Segmentation

This paper presents a review of deep learning (DL) in multi-organ segmentation. We summarized the latest DL-based methods for medical image segmentation and applications. These methods were classified into six categories according to their network design. For each category, we listed the surveyed works, highlighted important contributions and identified specific challenges. Following the detailed review of each category, we briefly discussed its achievements, shortcomings and future potentials. We provided a comprehensive comparison among DL-based methods for thoracic and head & neck multiorgan segmentation using benchmark datasets, including the 2017 AAPM Thoracic Auto-segmentation Challenge datasets and 2015 MICCAI Head Neck Auto-Segmentation Challenge datasets.

eess.IV

Machine Learning in Quantitative PET Imaging

This paper reviewed the machine learning-based studies for quantitative positron emission tomography (PET). Specifically, we summarized the recent developments of machine learning-based methods in PET attenuation correction and low-count PET reconstruction by listing and comparing the proposed methods, study designs and reported performances of the current published studies with brief discussion on representative studies. The contributions and challenges among the reviewed studies were summarized and highlighted in the discussion part followed by.

eess.IV

Deep Learning in Medical Image Registration: A Review

This paper presents a review of deep learning (DL) based medical image registration methods. We summarized the latest developments and applications of DL-based registration methods in the medical field. These methods were classified into seven categories according to their methods, functions and popularity. A detailed review of each category was presented, highlighting important contributions and identifying specific challenges. A short assessment was presented following the detailed review of each category to summarize its achievements and future potentials. We provided a comprehensive comparison among DL-based methods for lung and brain deformable registration using benchmark datasets. Lastly, we analyzed the statistics of all the cited works from various aspects, revealing the popularity and future trend of development in medical image registration using deep learning.

eess.IV

Radiomics in Cancer Radiotherapy: a Review

Radiomics is a nascent field in quantitative imaging that uses advanced algorithms and considerable computing power to describe tumor phenotypes, monitor treatment response, and assess normal tissue toxicity quantifiably. Remarkable interest has been drawn to the field due to its noninvasive nature and potential for diagnosing and predicting patient prognosis. This review will attempt to comprehensively and critically discuss the various aspects of radiomics including its workflow, applications to different modalities, potential applications in cancer radiotherapy, and limitations.

physics.med-ph

Air, bone and soft-tissue Segmentation on 3D brain MRI Using Semantic Classification Random Forest with Auto-Context Model

As bone and air produce weak signals with conventional MR sequences, segmentation of these tissues particularly difficult in MRI. We propose to integrate patch-based anatomical signatures and an auto-context model into a machine learning framework to iteratively segment MRI into air, bone and soft tissue. The proposed semantic classification random forest (SCRF) method consists of a training stage and a segmentation stage. During training stage, patch-based anatomical features were extracted from registered MRI-CT training images, and the most informative features were identified to train a series of classification forests with auto-context model. During segmentation stage, we extracted selected features from MRI and fed them into the well-trained forests for MRI segmentation. The DSC for air, bone and soft tissue obtained with proposed SCRF were 0.976, 0.819 and 0.932, compared to 0.916, 0.673 and 0.830 with RF, 0.942, 0.791 and 0.917 with U-Net. SCRF also demonstrated superior segmentation performances for sensitivity and specificity over RF and U-Net for all three structure types. The proposed segmentation technique could be a useful tool to segment bone, air and soft tissue, and have the potential to be applied to attenuation correction of PET/MRI system, MRI-only radiation treatment planning and MR-guided focused ultrasound surgery.

physics.med-ph