SearcharxivSearch

arXiv subjects

Watson Henderson

Publications and source records attributed to Watson Henderson.

2 recordsLinked to original sources

Observation of Plasma Bubble Structures in a GeV Laser-Plasma Accelerator

We measure characteristics of plasma bubbles in GeV-class laser-plasma accelerators (LPAs) using Faraday rotation diagnostics. We extend these techniques, previously demonstrated for LPAs in atmospheric density plasmas (electron density $n_e >10^{19}$ cm$^{-3}$), to LPAs in low-density plasmas ($n_e \approx 5\times10^{17}$ cm$^{-3}$), in which plasma bubbles are $\sim 5$ times larger, and correspondingly easier to visualize in detail. The signals show $\approx 0.5^\circ$ rotation streaks of opposite sign separated by $\sim50$ $μ$m, consistent with bubble diameter; no on-axis rotation; streaks length consistent with transverse probe pulse duration ($180$ $μ$m for $500$ fs pulse length, and $600$ $μ$m for $2$ ps pulse length). We utilized an anamorphic imaging system to obtain a wide longitudinal field of view ($>1$ cm) and a high transverse resolution ($<9$ $μ$m). We also demonstrated that Faraday rotation signals are sensitive to the stages of acceleration processes using extended 2D Finite Difference Time Domain (FDTD) simulation.

physics.plasm-ph

Compact tunable Compton x-ray source from laser-plasma accelerator and plasma mirror

We present an in-depth experimental-computational study of the parameters necessary to optimize a tunable, quasi-monoenergetic, efficient, low-background Compton backscattering (CBS) x-ray source that is based on the self-aligned combination of a laser-plasma accelerator (LPA) and a plasma mirror (PM). The main findings are: (1) an LPA driven in the blowout regime by 30 TW, 30 fs laser pulses producesnot only a high-quality, tunable, quasi-monoenergetic electron beam, but also a high-quality, relativistically intense (a0~1) spent drive pulse that remains stable in profile and intensity over the LPA tuning range. (2) A thin plastic film near the gas jet exit retro-reflects the spent drive pulse efficiently into oncoming electrons to produce CBS x-rays without detectable bremsstrahlung background. Meanwhile anomalous far-field divergence of the retro-reflected light demonstrates relativistic "denting" of the PM. Exploiting these optimized LPA and PM conditions, we demonstrate quasi-monoenergetic (50% FWHM energy spread), tunable (75 to 200 KeV) CBS x-rays, characteristics previously achieved only on more powerful laser systems by CBS of a split-off, counter-propagating pulse. Moreover, laser-to-x-ray photon conversion efficiency ~6e12 exceeds that of any previous LPA-based quasi-monoenergetic Compton source. Particle-in-cell simulations agree well with the measurements.

physics.plasm-ph