SearcharxivSearch

arXiv subjects

Weili Zhong

Publications and source records attributed to Weili Zhong.

5 recordsLinked to original sources

Neutron Beam Tests of Barium Fluoride Crystal for Dark Matter Direct Detection

In order to test the capabilities of Barium Fluoride (BaF2) Crystal for dark matter direct detection, nuclear recoils are studied with mono-energetic neutron beam. The energy spectra of nuclear recoils, quenching factors for elastic scattering neutrons and discrimination capability between neutron inelastic scattering events and γ events are obtained for various recoil energies of the F content in BaF2.

physics.ins-det

Neutron Beam Tests of $CsI(Na)$ and $CaF_{2}(Eu)$ Crystals for Dark Matter Direct Search

In recent decades, inorganic crystals have been widely used in dark matter direct search experiments. To contribute to the understanding of the capabilities of $CsI(Na)$ and $CaF_{2}(Eu)$ crystals, a mono-energetic neutron beam is utilized to study the properties of nuclear recoils, which are expected to be similar to signals of dark matter direct detection. The quenching factor of nuclear recoils in $CsI(Na)$ and $CaF_{2}(Eu)$, as well as an improved discrimination factor between nuclear recoils and $γ$ backgrounds in $CsI(Na)$, are reported.

physics.ins-det

Waterproofed Photomultiplier Tube Assemblies for the Daya Bay Reactor Neutrino Experiment

In the Daya Bay Reactor Neutrino Experiment 960 20-cm-diameter waterproof photomultiplier tubes are used to instrument three water pools as Cherenkov detectors for detecting cosmic-ray muons. Of these 960 photomultiplier tubes, 341 are recycled from the MACRO experiment. A systematic program was undertaken to refurbish them as waterproof assemblies. In the context of passing the water leakage check, a success rate better than 97% was achieved. Details of the design, fabrication, testing, operation, and performance of these waterproofed photomultiplier-tube assemblies are presented.

physics.ins-det

Advantages of Multiple Detectors for the Neutrino Mass Hierarchy Determination at Reactor Experiments

We study the advantages of a second identical detector at a medium baseline reactor neutrino experiment. A major obstruction to the determination of the neutrino mass hierarchy is the detector's unknown nonlinear energy response, which even under optimistic assumptions reduces the confidence in a hierarchy determination by about 1 sigma at a single detector experiment. Various energy response models are considered at one and two detector experiments with the same total target mass. A second detector at a sufficiently different baseline eliminates this 1 sigma reduction. Considering the unknown energy response, we find the confidence in a hierarchy determination at various candidate detector locations for JUNO and RENO 50. The best site for JUNO's near detector is under ZiLuoShan, 17 km and 66 km from the Yangjiang and Taishan reactor complexes respectively. We briefly describe other advantages, including a more precise determination of theta12 and the possibility of a DAEdALUS-inspired program to measure the CP-violating phase delta using a single pion source about 10 km from one detector and 20 km from the other. Two identical detectors provide a better energy resolution than a single (larger) detector, further increasing the confidence in a hierarchy determination.

hep-ph

Medium Baseline Reactor Neutrino Experiments with 2 Identical Detectors

In the next 10 years medium baseline reactor neutrino experiments will attempt to determine the neutrino mass hierarchy and to precisely measure θ_12. Both of these determinations will be more reliable if data from identical detectors at distinct baselines are combined. While interference effects can be eliminated by choosing detector sites orthogonal to the reactor arrays, one of the greatest challenges facing a determination of the mass hierarchy is the detector's unknown energy response. By comparing peaks at similar energies at two identical detectors at distinct baselines, one eliminates any correlated dependence upon a monotonic energy response. In addition, a second detector leads to new hierarchy-dependent observables, such as the ratio of the locations of the maxima of the Fourier cosine transforms. Simultaneously, one may determine the hierarchy by comparing the χ^2 best fits of ΔM^2_32 at the two detectors using the spectra associated to both hierarchies. A second detector at a distinct baseline also breaks the degeneracy between θ_12 and the background neutrino flux from, for example, distant reactors and increases the effective target mass, which is limited by current designs to about 20 kton/detector.

hep-ph