SearcharxivSearch

arXiv subjects

Weiling Huang

Publications and source records attributed to Weiling Huang.

3 recordsLinked to original sources

Extension of the operation mode of back-streaming white neutron beam at the China spallation neutron source

The back-streaming white neutron source (Back-n) is a comprehensive neutron experimental platform for nuclear data measurement, nuclear astrophysics, neutron irradiation, detector calibration, etc. In order to meet a variety of experimental requirements, an attempt of various combinations of collimators has been made for the current collimation system. The basic parameters such as beam flux and beam spot characteristics under different beam operation modes have been studied. According to the change of the CSNS proton beam operation mode, the influence of different proton beam spots on the Back-n beam is also studied. The study finds that some beam modes with new collimator combinations can meet the experimental requirements and greatly shorten the experimental time. In addition, we have found a parameterized formula for the uniform beam spot of the high-power proton beam based on the beam monitor data, which provides a more accurate proton-beam source term for future white neutron beam physics and application researches.

physics.ins-det

Measurements of differential and angle-integrated cross sections for the $^{10}$B($n, {\alpha}$)$^{7}$Li reaction in the neutron energy range from 1.0 eV to 2.5 MeV

Differential and angle-integrated cross sections for the $^{10}$B($n, {\alpha}$)$^{7}$Li, $^{10}$B($n, {\alpha}$$_{0}$)$^{7}$Li and $^{10}$B($n, {\alpha}$$_{1}$)$^{7}$Li$^{*}$ reactions have been measured at CSNS Back-n white neutron source. Two enriched (90%) $^{10}$B samples 5.0 cm in diameter and ~85.0 ${\mu}$g/cm$^{2}$ in thickness each with an aluminum backing were prepared, and back-to-back mounted at the sample holder. The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array (LPDA) system. The neutron energy E$_{n}$ was determined by TOF (time-of-flight) method, and the valid ${\alpha}$ events were extracted from the E$_{n}$-Amplitude two-dimensional spectrum. With 15 silicon detectors, the differential cross sections of ${\alpha}$-particles were measured from 19.2{\deg} to 160.8{\deg}. Fitted with the Legendre polynomial series, the ($n, {\alpha}$) cross sections were obtained through integration. The absolute cross sections were normalized using the standard cross sections of the $^{10}$B($n, {\alpha}$)$^{7}$Li reaction in the 0.3 - 0.5 MeV neutron energy region. The measurement neutron energy range for the $^{10}$B($n, {\alpha}$)$^{7}$Li reaction is 1.0 eV $\le$ En < 2.5 MeV (67 energy points), and for the $^{10}$B($n, {\alpha}$$_{0}$)$^{7}$Li and $^{10}$B($n, {\alpha}$$_{1}$)$^{7}$Li$^{*}$ reactions is 1.0 eV $\le$ En < 1.0 MeV (59 energy points). The present results have been analyzed by the resonance reaction mechanism and the level structure of the $^{11}$B compound system, and compared with existing measurements and evaluations.

nucl-ex

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

physics.ins-det