Searcharxiv⌕ Search

arXiv subjects

Weimin Yuan

Publications and source records attributed to Weimin Yuan.

At least 55 records · Page 3Linked to original sources

Triggering the Untriggered: The First Einstein Probe-Detected Gamma-Ray Burst 240219A and Its Implications

The Einstein Probe (EP) achieved its first detection and localization of a bright X-ray flare, EP240219a, on 2024 February 19, during its commissioning phase. Subsequent targeted searches triggered by the EP240219a alert identified a faint, untriggered gamma-ray burst (GRB) in the archived data of Fermi Gamma-ray Burst Monitor (GBM), Swift Burst Alert Telescope (BAT), and Insight-HXMT/HE. The EP Wide-field X-ray Telescope (WXT) light curve reveals a long duration of approximately 160 s with a slow decay, whereas the Fermi/GBM light curve shows a total duration of approximately 70 s. The peak in the Fermi/GBM light curve occurs slightly later with respect to the peak seen in the EP/WXT light curve. Our spectral analysis shows that a single cutoff power-law (PL) model effectively describes the joint EP/WXT--Fermi/GBM spectra in general, indicating coherent broad emission typical of GRBs. The model yielded a photon index of $\sim -1.70 \pm 0.05$ and a peak energy of $\sim 257 \pm 134$ keV. After detection of GRB 240219A, long-term observations identified several candidates in optical and radio wavelengths, none of which was confirmed as the afterglow counterpart during subsequent optical and near-infrared follow-ups. The analysis of GRB 240219A classifies it as an X-ray rich GRB (XRR) with a high peak energy, presenting both challenges and opportunities for studying the physical origins of X-ray flashes, XRRs, and classical GRBs. Furthermore, linking the cutoff PL component to nonthermal synchrotron radiation suggests that the burst is driven by a Poynting flux-dominated outflow.

astro-ph.HE↗

Einstein Probe discovery of EP240408a: a peculiar X-ray transient with an intermediate timescale

We report the discovery of a peculiar X-ray transient, EP240408a, by Einstein Probe (EP) and follow-up studies made with EP, Swift, NICER, GROND, ATCA and other ground-based multi-wavelength telescopes. The new transient was first detected with Wide-field X-ray Telescope (WXT) on board EP on April 8th, 2024, manifested in an intense yet brief X-ray flare lasting for 12 seconds. The flare reached a peak flux of 3.9x10^(-9) erg/cm2/s in 0.5-4 keV, about 300 times brighter than the underlying X-ray emission detected throughout the observation. Rapid and more precise follow-up observations by EP/FXT, Swift and NICER confirmed the finding of this new transient. Its X-ray spectrum is non-thermal in 0.5-10 keV, with a power-law photon index varying within 1.8-2.5. The X-ray light curve shows a plateau lasting for about 4 days, followed by a steep decay till becoming undetectable about 10 days after the initial detection. Based on its temporal property and constraints from previous EP observations, an unusual timescale in the range of 7-23 days is found for EP240408a, which is intermediate between the commonly found fast and long-term transients. No counterparts have been found in optical and near-infrared, with the earliest observation at 17 hours after the initial X-ray detection, suggestive of intrinsically weak emission in these bands. We demonstrate that the remarkable properties of EP240408a are inconsistent with any of the transient types known so far, by comparison with, in particular, jetted tidal disruption events, gamma-ray bursts, X-ray binaries and fast blue optical transients. The nature of EP240408a thus remains an enigma. We suggest that EP240408a may represent a new type of transients with intermediate timescales of the order of about 10 days. The detection and follow-ups of more of such objects are essential for revealing their origin.

astro-ph.HE↗

X-ray Sources Classification Using Machine Learning: A Study with EP-WXT Pathfinder LEIA

X-ray observations play a crucial role in time-domain astronomy. The Einstein Probe (EP), a recently launched X-ray astronomical satellite, emerges as a forefront player in the field of time-domain astronomy and high-energy astrophysics. With a focus on systematic surveys in the soft X-ray band, EP aims to discover high-energy transients and monitor variable sources in the universe. To achieve these objectives, a quick and reliable classification of observed sources is essential. In this study, we developed a machine learning classifier for autonomous source classification using data from the EP-WXT Pathfinder Lobster Eye Imager for Astronomy (LEIA) and EP-WXT simulations. The proposed Random Forest classifier, built on selected features derived from light curves, energy spectra, and location information, achieves an accuracy of approximately 95% on EP simulation data and 98% on LEIA observational data. The classifier is integrated into the LEIA data processing pipeline, serving as a tool for manual validation and rapid classification during observations. This paper presents an efficient method for the classification of X-ray sources based on single observations, along with implications of most effective features for the task. This work facilitates rapid source classification for the EP mission and also provides valuable insights into feature selection and classification techniques for enhancing the efficiency and accuracy of X-ray source classification that can be adapted to other X-ray telescope data.

astro-ph.IM↗

The fast X-ray transient EP240315a: a z ~ 5 gamma-ray burst in a Lyman continuum leaking galaxy

The nature of the minute-to-hour long Fast X-ray Transients (FXTs) localised by telescopes such as Chandra, Swift, and XMM-Newton remains mysterious, with numerous models suggested for the events. Here, we report multi-wavelength observations of EP240315a, a 1600 s long transient detected by the Einstein Probe, showing it to have a redshift of z=4.859. We measure a low column density of neutral hydrogen, indicating that the event is embedded in a low-density environment, further supported by direct detection of leaking ionising Lyman-continuum. The observed properties are consistent with EP240315a being a long-duration gamma-ray burst, and these observations support an interpretation in which a significant fraction of the FXT population are lower-luminosity examples of similar events. Such transients are detectable at high redshifts by the Einstein Probe and, in the (near) future, out to even larger distances by SVOM, THESEUS, and Athena, providing samples of events into the epoch of reionisation.

astro-ph.HE↗

Future Perspectives for Gamma-ray Burst Detection from Space

Since their first discovery in the late 1960s, Gamma-ray bursts have attracted an exponentially growing interest from the international community due to their central role in the most highly debated open questions of the modern research of astronomy, astrophysics, cosmology, and fundamental physics. These range from the intimate nuclear composition of high density material within the core of ultra-dense neuron stars, to stellar evolution via the collapse of massive stars, the production and propagation of gravitational waves, as well as the exploration of the early Universe by unveiling first stars and galaxies (assessing also their evolution and cosmic re-ionization). GRBs have stimulated in the past $\sim$50 years the development of cutting-edge technological instruments for observations of high energy celestial sources from space, leading to the launch and successful operations of many different scientific missions (several of them still in data taking mode nowadays). In this review, we provide a brief description of the GRB-dedicated missions from space being designed and developed for the future. The list of these projects, not meant to be exhaustive, shall serve as a reference to interested readers to understand what is likely to come next to lead the further development of GRB research and associated phenomenology.

astro-ph.IM↗

Radiation Effects on Scientific CMOS Detectors for X-ray Astronomy: II. Total Ionizing Dose Irradiation

Complementary metal-oxide-semiconductor (CMOS) detectors are a competitive choice for current and upcoming astronomical missions. To understand the performance variations of CMOS detectors in space environment, we investigate the total ionizing dose effects on custom-made large-format X-ray CMOS detectors. Three CMOS detector samples were irradiated with a Co-60 source with a total dose of 70 krad and 105 krad. We test and compare the performance of these detectors before and after irradiation. After irradiation, the dark current increases by roughly 20 to 100 times, and the readout noise increases from 3 e- to 6 e-. The bias level at 50 ms integration time decreases by 13 to 18 Digital Number (DN) at -30 degree. The energy resolution increases from about 150 eV to about 170 eV at 4.5 keV at -30 degree. The conversion gain of the detectors varies for less than 2% after the irradiation. Furthermore, there are about 50 pixels whose bias at 50 ms has changed by more than 20 DN after the exposure to the radiation and about 30 to 140 pixels whose readout noise has increased by over 20 e- at -30 degree at 50 ms integration time. These results demonstrate that the performances of large-format CMOS detectors do not suffer significant degeneration in space environment.

astro-ph.IM↗

Ground Calibration Result of the Lobster Eye Imager for Astronomy

We report on results of the on-ground X-ray calibration of the Lobster Eye Imager for Astronomy (LEIA), an experimental space wide-field (18.6*18.6 square degrees) X-ray telescope built from novel lobster eye mirco-pore optics. LEIA was successfully launched on July 27, 2022 onboard the SATech-01 satellite. To achieve full characterisation of its performance before launch, a series of tests and calibrations have been carried out at different levels of devices, assemblies and the complete module. In this paper, we present the results of the end-to-end calibration campaign of the complete module carried out at the 100-m X-ray Test Facility at IHEP. The PSF, effective area and energy response of the detectors were measured in a wide range of incident directions at several X-ray line energies. The distributions of the PSF and effective areas are roughly uniform across the FoV, in large agreement with the prediction of lobster-eye optics. The mild variations and deviations from the prediction of idealized lobster-eye optics can be understood to be caused by the imperfect shapes and alignment of the micro-pores as well as the obscuration by the supporting frames, which can be well reproduced by MC simulations. The spatial resolution of LEIA defined by the FWHM of the focal spot ranges from 4-8 arcmin with a median of 5.7. The measured effective areas are in range of 2-3 $cm^2$ at ~1.25 keV across the entire FoV, and its dependence on photon energy is in large agreement with simulations. The gains of the CMOS sensors are in range of 6.5-6.9 eV/DN, and the energy resolutions in the range of ~120-140 eV at 1.25 keV and ~170-190 eV at 4.5 keV. These results have been ingested into the calibration database and applied to the analysis of the scientific data acquired by LEIA. This work paves the way for the calibration of the Wide-field X-Ray Telescope modules of the Einstein Probe mission.

astro-ph.IM↗

Constraining the X-ray radiation origin of 3C 273 in the low state by polarization

3C 273 is one of the nearest high-luminosity quasars. Although classified as a blazar, 3C 273 also has some features in Seyferts, whose X-ray may originate from the corona. Since both jet and corona produce power-law spectra in X-ray, the spectrum cannot completely distinguish their contributions to 3C 273 in the low state. X-ray polarimetric observations provide the chance to constrain the X-ray radiation origin of 3C 273 in the low state. We perform general relativistic radiative transfer simulations with the code MONK to compute the X-ray polarization in 2-10 keV from the jets, sphere coronae, and slab coronae for 3C 273. We find that the radiation from the jet in 2-10 keV has a larger polarization degree than that of the corona: the polarization degree in 2-10 keV from the corona is unpolarized, while these are 4.1%-15.8% for the jet with a vertical or radial magnetic field and $\leq$5.0% for the jet with toroidal magnetic field. The X-ray polarization of the corona and jet is sensitive to optical depth and geometry, and the main driver for this dependence is the number of scatterings. These results show that X-ray polarization can effectively constrain the X-ray radiation origin of 3C 273 in the low state.

astro-ph.HE↗

Radiation effects on scientific CMOS sensors for X-ray astronomy: I. proton irradiation

Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the impact of irradiation on the performance of two scientific CMOS (sCMOS) sensors between -30 to 20 degree at high gain mode (7.5 times), including the bias map, readout noise, dark current, conversion gain, and energy resolution. The two sensors are irradiated with 50 MeV protons with a total dose of 5.3*10^10 p/cm^2. After the exposure, the bias map, readout noise and conversion gain at various temperatures are not significantly degraded, nor is the energy resolution at -30 degree. However, after the exposure the dark current has increased by hundreds of times, and for every 20 degree increase in temperature, the dark current also increases by an order of magnitude. Therefore, at room temperature, the fluctuations of the dark currents dominate the noise and lead to a serious degradation of the energy resolution. Moreover, among the 4k * 4k pixels, there are about 100 pixels whose bias at 50 ms has changed by more than 10 DN (~18 e-), and about 10 pixels whose readout noise has increased by over 15 e- at -30 degree. Fortunately, the influence of the dark current can be reduced by decreasing the integration time, and the degraded pixels can be masked by regular analysis of the dark images. Some future X-ray missions will likely operate at -30 degree, under which the dark current is too small to significantly affect the X-ray performance. Our investigations show the high tolerance of the sCMOS sensors for proton radiation and prove their suitability for X-ray astronomy applications.

astro-ph.IM↗

An Aluminum-coated sCMOS sensor for X-Ray Astronomy

In recent years, tremendous progress has been made on scientific Complementary Metal Oxide Semiconductor (sCMOS) sensors, making them a promising device for future space X-ray missions. We have customized a large-format sCMOS sensor, G1516BI, dedicated for X-ray applications. In this work, a 200 nm thick aluminum layer is successfully sputtered on the surface of this sensor. This Al-coated sensor, named EP4K, shows consistent performance with the uncoated version. The readout noise of the EP4K sensor is around 2.5 e- and the dark current is less than 0.01 e-/pixel/s at -30 degree. The maximum frame rate is 20 Hz in the current design. The ratio of single pixel events of the sensor is 45.0%. The energy resolution can reach 153.2 eV at 4.51 keV and 174.2 eV at 5.90 keV at -30 degree. The optical transmittance of the aluminum layer is approximately 1e-8 to 1e-10 for optical lights from 365 to 880 nm, corresponding to an effective aluminum thickness of around 140 to 160 nm. The good X-ray performance and low optical transmittance of this Al-coated sCMOS sensor make it a good choice for space X-ray missions. The Lobster Eye Imager for Astronomy (LEIA), which has been working in orbit for about one year, is equipped with four pieces of EP4K sensors. Furthermore, 48 pieces of EP4K sensors are used on the Wide-field X-ray Telescope (WXT) on the Einstein Probe (EP) satellite, which will be launched at the end of 2023.

astro-ph.IM↗

SAMIHS: Adaptation of Segment Anything Model for Intracranial Hemorrhage Segmentation

Segment Anything Model (SAM), a vision foundation model trained on large-scale annotations, has recently continued raising awareness within medical image segmentation. Despite the impressive capabilities of SAM on natural scenes, it struggles with performance decline when confronted with medical images, especially those involving blurry boundaries and highly irregular regions of low contrast. In this paper, a SAM-based parameter-efficient fine-tuning method, called SAMIHS, is proposed for intracranial hemorrhage segmentation, which is a crucial and challenging step in stroke diagnosis and surgical planning. Distinguished from previous SAM and SAM-based methods, SAMIHS incorporates parameter-refactoring adapters into SAM's image encoder and considers the efficient and flexible utilization of adapters' parameters. Additionally, we employ a combo loss that combines binary cross-entropy loss and boundary-sensitive loss to enhance SAMIHS's ability to recognize the boundary regions. Our experimental results on two public datasets demonstrate the effectiveness of our proposed method. Code is available at https://github.com/mileswyn/SAMIHS .

eess.IV↗

Investigating the image lag of a scientific CMOS sensor in X-ray detection

In recent years, scientific CMOS (sCMOS) sensors have been vigorously developed and have outperformed CCDs in several aspects: higher readout frame rate, higher radiation tolerance, and higher working temperature. For silicon image sensors, image lag will occur when the charges of an event are not fully transferred inside pixels. It can degrade the image quality for optical imaging, and deteriorate the energy resolution for X-ray spectroscopy. In this work, the image lag of a sCMOS sensor is studied. To measure the image lag under low-light illumination, we constructed a new method to extract the image lag from X-ray photons. The image lag of a customized X-ray sCMOS sensor GSENSE1516BSI is measured, and its influence on X-ray performance is evaluated. The result shows that the image lag of this sensor exists only in the immediately subsequent frame and is always less than 0.05% for different incident photon energies and under different experimental conditions. The residual charge is smaller than 0.5 e- with the highest incident photon charge around 8 ke-. Compared to the readout noise level around 3 e-, the image lag of this sensor is too small to have a significant impact on the imaging quality and the energy resolution. The image lag shows a positive correlation with the incident photon energy and a negative correlation with the temperature. However, it has no dependence on the gain setting and the integration time. These relations can be explained qualitatively by the non-ideal potential structure inside the pixels. This method can also be applied to the study of image lag for other kinds of imaging sensors.

astro-ph.IM↗

Improving the X-ray energy resolution of a scientific CMOS detector by pixel-level gain correction

Scientific Complementary Metal Oxide Semiconductor (sCMOS) sensors are finding increasingly more applications in astronomical observations, thanks to their advantages over charge-coupled devices (CCDs) such as a higher readout frame rate, higher radiation tolerance, and higher working temperature. In this work, we investigate the performance at the individual pixel level of a large-format sCMOS sensor, GSENSE1516BSI, which has 4096 * 4096 pixels, each of 15 μm in size. To achieve this, three areas on the sCMOS sensor, each consisting of 99 * 99 pixels, are chosen for the experiment. The readout noise, conversion gain and energy resolutions of the individual pixels in these areas are measured from a large number (more than 25,000) of X-ray events accumulated for each of the pixels through long time exposures. The energy resolution of these pixels can reach 140 eV at 6.4 keV at room temperature and shows a significant positive correlation with the readout noise. The accurate gain can also be derived individually for each of the pixels from its X-ray spectrum obtained. Variations of the gain values are found at a level of 0.56% statistically among the 30 thousand pixels in the areas studied. With the gain of each pixel determined accurately, a precise gain correction is performed pixel by pixel in these areas, in contrast to the standardized ensemble gain used in the conventional method. In this way, we could almost completely eliminate the degradation of energy resolutions caused by gain variations among pixels. As a result, the energy resolution at room temperature can be significantly improved to 124.6 eV at 4.5 keV and 140.7 eV at 6.4 keV. This pixel-by-pixel gain correction method can be applied to all kinds of CMOS sensors, and is expected to find interesting applications in X-ray spectroscopic observations in the future.

astro-ph.IM↗

The radio structure of the $γ$-ray narrow-line Seyfert 1 galaxy SDSS J211852.96$-$073227.5

The $γ$-ray narrow-line Seyfert 1 (NLS1) galaxies can be considered to be the third class of $γ$-ray active galactic nuclei possessing relativistic jets. In this paper, we present multi-band high resolution Very Long Baseline Array (VLBA) images of the $γ$-ray NLS1, SDSS J211852.96$-$073227.5 (J2118$-$0732, $z=0.26$). We find a core-jet radio morphology and significant flux density variations in the radio core. The high brightness temperature estimated from VLBA images and core variability demonstrate that it exhibits substantial relativistic beaming effects. From considering radio emission in several bands, we find that the source has an inverted spectrum above 1 GHz but a steep spectrum at low frequencies from 74 MHz to 1 GHz; these may arise from the present activity and the old diffuse/extended emission, respectively. The core-jet morphology, significant flux density variations, and beaming effect make J2118$-$0732 resemble a blazar. Considering the low mass of its central black hole and ongoing merger environment, J2118$-$0732 may represent a low-mass, low-power counterpart of blazars, and may finally evolve to a blazar.

astro-ph.HE↗

X-ray Performance of a Small Pixel Size sCMOS Sensor and the Effect of Depletion Depth

In recent years, scientific Complementary Metal Oxide Semiconductor (sCMOS) devices have been increasingly applied in X-ray detection, thanks to their attributes such as high frame rate, low dark current, high radiation tolerance and low readout noise. We tested the basic performance of a backside-illuminated (BSI) sCMOS sensor, which has a small pixel size of 6.5 um * 6.5 um. At a temperature of -20C, The readout noise is 1.6 e, the dark current is 0.5 e/pixel/s, and the energy resolution reaches 204.6 eV for single-pixel events. The effect of depletion depth on the sensor's performance was also examined, using three versions of the sensors with different deletion depths. We found that the sensor with a deeper depletion region can achieve a better energy resolution for events of all types of pixel splitting patterns, and has a higher efficiency in collecting photoelectrons produced by X-ray photons. We further study the effect of depletion depth on charge diffusion with a center-of-gravity (CG) model. Based on this work, a highly depleted sCMOS is recommended for applications of soft X-ray spectroscop.

physics.ins-det↗

X-ray performance of a customized large-format scientifc CMOS detector

In recent years, the performance of Scientifc Complementary Metal Oxide Semiconductor (sCMOS) sensors has been improved signifcantly. Compared with CCD sensors, sCMOS sensors have various advantages, making them potentially better devices for optical and X-ray detection, especially in time-domain astronomy. After a series of tests of sCMOS sensors, we proposed a new dedicated high-speed, large-format X-ray detector in 2016 cooperating with Gpixel Inc. This new sCMOS sensor has a physical size of 6 cm by 6 cm, with an array of 4096 by 4096 pixels and a pixel size of 15 um. The frame rate is 20.1 fps under current condition and can be boosted to a maximum value around 100 fps. The epitaxial thickness is increased to 10 um compared to the previous sCMOS product. We show the results of its frst taped-out product in this work. The dark current of this sCMOS is lower than 10 e/pixel/s at 20C, and lower than 0.02 e/pixel/s at -30C. The Fixed Pattern Noise (FPN) and the readout noise are lower than 5 e in high-gain situation and show a small increase at low temperature. The energy resolution reaches 180.1 eV (3.1%) at 5.90 keV for single-pixel events and 212.3 eV (3.6%) for all split events. The continuous X-ray spectrum measurement shows that this sensor is able to response to X-ray photons from 500 eV to 37 keV. The excellent performance, as demonstrated from these test results, makes sCMOS sensor an ideal detector for X-ray imaging and spectroscopic application.

astro-ph.IM↗

Design and test results of scientific X-ray CMOS cameras

In recent years, scientific CMOS (sCMOS) sensors have found increasing applications to X-ray detection, including X-ray astronomical observations. In order to examine the performance of sCMOS sensors, we have developed X-ray cameras based on sCMOS sensors. Two cameras, CNX22 and CNX 66, have been developed using sCMOS sensors with a photosensitive area of 2 cm * 2 cm and 6 cm * 6 cm, respectively. The designs of the cameras are presented in this paper. The CNX22 camera has a frame rate of 48 fps, whereas CNX66 has a frame rate of currently 20 fps, that can be boosted to 100 fps in the future. The operating temperature of the sCMOS sensor can reach to -20C for CNX22 and -30C for CNX66 with a peltier cooler device. In addition to the commonly used mode of saving original images, the cameras provide a mode of real-time extraction of X-ray events and storage their information, which significantly reduces the requirement for data storage and offline analysis work. For both cameras, the energy resolutions can reach less than 200 eV at 5.9 keV using single-pixel events. These cameras are suitable for X-ray spectroscopy applications in laboratories and calibration for the space X-ray telescopes.

astro-ph.IM↗

The Einstein Probe Mission

The Einstein Probe (EP) is a mission designed to monitor the sky in the soft X-ray band. It will perform systematic surveys and characterisation of high-energy transients and monitoring of variable objects at unprecedented sensitivity and monitoring cadences. It has a large instantaneous field-of-view (3,600 sq. deg.), that is realised via the lobster-eye micro-pore X-ray focusing optics. EP also carries a conventional X-ray focusing telescope with a larger effective area to perform followup observations and precise positioning of newly-discovered transients. Alerts for transient objects will be issued publicly and timely. The scientific goals of EP are concerned with discovering faint, distant or rare types of high-energy transients and variable sources. Within the confines of a modest-sized mission, EP will cover a wide range of scientific topics, from the nearby to high-redshift Universe. The Einstein Probe is a mission of the Chinese Academy of Sciences, and also an international collaborative project. This paper presents the background, scientific objectives, and the mission design including the micro-pore optics and CMOS technologies adopted, the instruments and their expected performance, and the mission profile. The development status of the project is also presented.

astro-ph.HE↗