Searcharxiv⌕ Search

arXiv subjects

Wellington Avelino

Publications and source records attributed to Wellington Avelino.

5 recordsLinked to original sources

Functional Interface Blocks for Neuromorphic Hardware: A Junction-Centered Framework

Heterogeneous neuromorphic hardware integrates devices with dissimilar electrical characteristics and dynamics, making functional compatibility at their interconnections a primary design challenge. Direct coupling alone is insufficient to ensure correct operation, because the load-line conditions established at each junction determine the effective operating regime. Here, we propose a junction-centered interface framework in which inter-device connections are described through assigned drive/sense roles and organized into canonical functional interface blocks. As a concrete hardware realization, a second-generation current conveyor (CCII)-based implementation is then adopted as a composite realization of these interface primitives. The framework is validated experimentally in a Pavlovian-conditioning demonstrator combining a memristive synapse with a unijunction-transistor (UJT) post-neuron. By linking local junction conditions to reusable interface functions, the proposed methodology provides a systematic basis for the design and analysis of heterogeneous neuromorphic systems.

cs.ET↗

A High-Bandwidth Backplane for Wideband Radio Interferometers and Integration with the CHORD Telescope Correlators

Wide-band correlators for radio astronomy interferometers demand accurate, scalable signal processing backends that sustain high aggregate throughput while preserving stable timing alignment across a large number of signal chains. Addressing these coupled constraints is challenging without a co-designed backplane architecture. We present a backplane system developed for the Control Readout System (CRS) Field Programmable Gate Array (FPGA) platform, extending its capabilities to support high channel count wideband radio correlators. The design and validation process are guided by the requirements of the Canadian Hydrogen Observatory and Radio-transient Detector (CHORD) telescope, which provides a representative use case for the system's performance evaluation. Each backplane hosts up to four CRS boards, and a single crate integrates four interconnected backplanes to accommodate sixteen CRS modules (for a total of 128 digitized inputs per crate) interconnected through 25 Gbps per-lane links and an on-backplane data shuffle network. Comprehensive validation demonstrates robust high-speed link performance, sub-sampling-level timing alignment stability, and stable thermal and power behavior across environmental variations. The architecture delivers observatory-scale scalability, providing a low-jitter and phase-consistent foundation for wideband digital correlators. By supporting expansion from single-crate to multi-crate configurations without firmware modification, the system offers a practical and flexible path toward next-generation interferometers requiring tightly synchronized, high-throughput digital backends.

astro-ph.IM↗

The CRS: a scalable full-stack control system for Microwave Kinetic Inductance Detectors

The t0.technology Control and Readout System (CRS) is a modular microwave control and readout system for mm-wave and radio astronomy, THz imaging, noise radar, and superconducting qubit control. The configuration discussed in this work implements firmware for readout of microwave Kinetic Inductance Detector (KID) arrays. The CRS can operate 4,096 KIDs over 2.5 GHz of complex bandwidth between 0-10 GHz, typically allocated across four independent RF chains at 1,024x multiplexing and 625 MHz of complex bandwidth each. Every CRS can operate as a standalone unit or collectively within one or more backplane-enabled subracks that distribute power, clocking, and synchronization, scaling to an arbitrary number of channels. Each fully populated subrack supports arrays of more than 65,000 KIDs. The signal processing and control software supports recent innovations in multi-probe measurements and dynamic feedback modes, which are described in (Rouble et al. 2024). The CRS has recently been selected as the new baseline readout system for the proposed South Pole Telescope instrument, SPT-3G+. We present the hardware design, firmware capabilities, open-source control and data acquisition software, and the first laboratory characterization measurements.

astro-ph.IM↗

Progress Towards Decoding Visual Imagery via fNIRS

We demonstrate the possibility of reconstructing images from fNIRS brain activity and start building a prototype to match the required specs. By training an image reconstruction model on downsampled fMRI data, we discovered that cm-scale spatial resolution is sufficient for image generation. We obtained 71% retrieval accuracy with 1-cm resolution, compared to 93% on the full-resolution fMRI, and 20% with 2-cm resolution. With simulations and high-density tomography, we found that time-domain fNIRS can achieve 1-cm resolution, compared to 2-cm resolution for continuous-wave fNIRS. Lastly, we share designs for a prototype time-domain fNIRS device, consisting of a laser driver, a single photon detector, and a time-to-digital converter system.

eess.IV↗

The limits of Near Field Immersion Microwave Microscopy evaluated by imaging bilayer graphene Moiré patterns

Molecular and atomic imaging required the development of electron and scanning probe microscopies to surpass the physical limits dictated by diffraction. Nano-infrared experiments and pico-cavity tip-enhanced Raman spectroscopy imaging later demonstrated that radiation in the visible range can surpass this limit by using scanning probe tips to access the near-field regime. Here we show that ultimate resolution can be obtained by using scanning microwave imaging microscopy to reveal structures with feature sizes down to 1~nm using a radiation of 0.1~m in wavelength. As a test material we use twisted bilayer graphene, which is not only a very important recent topic due to the discovery of correlated electron effects such as superconductivity, but also because it provides a sample where we can systematically tune a superstructure Moiré patterns modulation from below one up to tens of nanometers. By analyzing the tip-sample distance dynamics, we demonstrate that this ultimate 10$^8$ probe-to-pattern resolution can be achieved by using liquid immersion microscopy concepts and exquisite force control exerted on nanoscale water menisci.

cond-mat.mtrl-sci↗