SearcharxivSearch

arXiv subjects

Wensi Wu

Publications and source records attributed to Wensi Wu.

15 recordsLinked to original sources

An Octahedral Fibrous Constitutive Model for Heart Valve Mechanics and Function

Fibrous soft tissues derive their nonlinear mechanical response from networks of extracellular matrix fibers, whose organization gives rise to strain stiffening, the reverse Poynting effect, and anisotropic mechanical behavior. Motivated by these coupled features, we develop an anisotropic hyperelastic model for fibrous biological tissues that accounts for the contribution of the fiber network under both tensile and compressive deformation. We calibrate the model to experimental data for mitral valve leaflets using an inverse finite element approach that is coupled to automatic differentiation to facilitate efficient parameter calibration. Using the calibrated model, we investigate how anisotropy and fiber reorientation affect valve deformation under physiological loading. The results show that greater leaflet compliance in the radial direction yields proper valve closure, whereas localized fiber reorientation leads to stress concentrations that may promote progressive functional degradation. Fiber reorientation that makes the circumferential direction more compliant than the radial direction compromises valve closure and leads to mitral regurgitation. Chordal softening further amplifies the severity of this regurgitant response. These findings suggest that alterations in fiber architecture, especially when accompanied by chordal degradation, can contribute to the onset and progression of mitral valve incompetence.

q-bio.TO

A geometric feature tracking approach for noninvasive patient specific estimation of leaflet strain from 3D images of heart valves

Valvular heart disease is prevalent and a major contributor to heart failure. Valve leaflet strain is a promising metric for evaluating the mechanics underlying the initiation and progression of valvular pathology. However, generalizable methods for noninvasively quantifying valvular strain from clinically acquired patient images remain limited. To address this limitation, we developed a geometric feature-tracking framework to quantify in vivo leaflet strain from 3DE images. The method integrates a cohort-derived geometric reference atlas to establish geometric correspondence and introduces a novel distance-weighted coherent point drift algorithm for non-rigid registration. We evaluated performance against a finite element benchmark model and compared the approach with conventional point-based tracking methods. The framework was applied to pediatric and adult patient datasets (N = 31) across variable valve morphologies. The proposed method demonstrated greater accuracy in quantifying anatomical alignment and leaflet strain than conventional point-based approaches. Validation against the finite element benchmark confirmed improved strain estimation. The framework achieved reliable inter-phase tracking of valve deformation across diverse morphologies in pediatric and adult patients. Analysis identified a consistent distribution pattern of the 1st principal strain associated with leaflet billow (prolapse). This feature-tracking framework provides a generalizable method for noninvasive quantification of atrioventricular valve leaflet strain from clinical 3DE images. Characterization of biomechanical strain patterns may improve prognostic assessment and support longitudinal evaluation of valvular heart disease. Further investigation of the biomechanical signatures of heart valve disease has the potential to enhance prognostic assessment and longitudinal evaluation of valvular heart disease.

q-bio.QM

Biomechanically Informed Image Registration for Patient-Specific Aortic Valve Strain Analysis

Aortic valve (AV) biomechanics play a critical role in maintaining normal cardiac function. Pathological variations, particularly in bicuspid aortic valves, alter leaflet loading, increase strain, and accelerate disease progression. Accurate patient-specific characterization of valve geometry and deformation is therefore essential for predicting disease progression and guiding durable repair. Current imaging and computational methods often fail to capture rapid valve motion and complex patient-specific features, limiting precise biomechanical assessment. To address these limitations, we developed an image registration framework coupled with the finite element method (FEM) to improve AV tracking and biomechanical evaluation. The valve geometries derived from 4D echocardiography and CT were used to simulate AV closure and generate intermediate deformation states. These FEM-generated states facilitated leaflet tracking, while image registration corrected misalignment between simulations and imaging data. In 20 patients, FEM-augmented registration improved accuracy by 40% compared with direct registration. This improvement enabled more reliable strain estimation by measuring leaflet deformation directly from imaging and reducing uncertainties associated with boundary conditions and material assumptions. Areal, Green-Lagrange, and deviatoric strains were quantified in adult trileaflet/bicuspid valves, as well as pediatric patients, revealing distinct deformation patterns across valve groups. Convergence in mean deviatoric strain between adult trileaflet and pediatric valves suggests volumetric deformation underlies age- and size-related differences in AV mechanics. The FEM-augmented registration enhances tracking and biomechanical evaluation accuracy, providing clinically relevant insights into patient-specific AV deformation to support individualized medical and intervention planning.

q-bio.QM

An open-source computational framework for immersed fluid-structure interaction modeling using FEBio and MFEM

Fluid-structure interaction (FSI) simulation of biological systems presents significant computational challenges, particularly for applications involving large structural deformations and contact mechanics, such as heart valve dynamics. Traditional ALE methods encounter fundamental difficulties with such problems due to mesh distortion, motivating immersed techniques. This work presents a novel open-source immersed FSI framework that strategically couples two mature finite element libraries: MFEM, a GPU-ready and scalable library with state-of-the-art parallel performance developed at LLNL, and FEBio, a nonlinear finite element solver with sophisticated solid mechanics capabilities designed for biomechanics applications developed at the University of Utah and Columbia University. This coupling creates a unique synergy wherein the fluid solver leverages MFEM's distributed-memory parallelization and pathway to GPU acceleration, while the immersed solid exploits FEBio's comprehensive suite of hyperelastic and viscoelastic constitutive models and advanced solid mechanics modeling targeted for biomechanics applications. FSI coupling is achieved using a fictitious domain methodology with variational multiscale stabilization for enhanced accuracy on under-resolved grids expected with unfitted meshes used in immersed FSI. A fully implicit, monolithic scheme provides robust coupling for strongly coupled FSI characteristic of cardiovascular applications. The framework's modular architecture facilitates straightforward extension to additional physics and element technologies. Several test problems are considered to demonstrate the capabilities of the proposed framework, including a 3D semilunar heart valve simulation. This platform addresses a critical need for open-source immersed FSI software combining advanced biomechanics modeling with high-performance computing infrastructure.

q-bio.QM

Effect of Right Ventricular Outflow Tract Material Properties on Simulated Transcatheter Pulmonary Placement

Finite element (FE) simulations emulating transcatheter pulmonary valve (TPV) system deployment in patient-specific right ventricular outflow tracts (RVOT) assume material properties for the RVOT and adjacent tissues. Sensitivity of the deployment to variation in RVOT material properties is unknown. Moreover, the effect of a transannular patch stiffness and location on simulated TPV deployment has not been explored. A sensitivity analysis on the material properties of a patient-specific RVOT during TPV deployment, modeled as an uncoupled HGO material, was conducted using FEBioUncertainSCI. Further, the effects of a transannular patch during TPV deployment were analyzed by considering two patch locations and four patch stiffnesses. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio. Sensitivity analysis revealed that the shear modulus of the ground matrix (c), fiber modulus (k1), and fiber mean orientation angle (gamma) had the greatest effect on 95th %ile stress, whereas only c had the greatest effect on 95th %ile Lagrangian strain. First-order sensitivity indices contributed the greatest to the total-order sensitivity indices. Simulations using a transannular patch revealed that peak stress and strain were dependent on patch location. As stiffness of the patch increased, greater stress was observed at the interface connecting the patch to the RVOT, and stress in the patch itself increased while strain decreased. The total enclosed volume by the TPV device remained unchanged across all simulated patch cases. This study highlights that while uncertainties in tissue material properties and patch locations may influence functional outcomes, FE simulations provide a reliable framework for evaluating these outcomes in TPVR.

physics.med-ph

Integrated Open-Source Framework for Simulation of Transcatheter Pulmonary Valves in Native Right Ventricular Outflow Tracts

Background - Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF), leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement (TPVR) has become common, but assessment of patient candidacy and selection of the optimal device remains challenging. We demonstrate an integrated open-source workflow for simulation of TPVR in image-derived models to inform device selection. Methods - Machine learning-based segmentation of CT scans was implemented to define the right ventricular outflow tract (RVOT). A custom workflow for device positioning and pre-compression was implemented in SlicerHeart. Resulting geometries were exported to FEBio for simulation. Visualization of results and quantification were performed using custom metrics implemented in SlicerHeart and FEBio. Results - RVOT model creation and device placement could be completed in under 1 minute. Virtual device placement using FE simulations visually mimicked actual device placement and allowed quantification of vessel strain, stress, and contact area. Regions of higher strain and stress were observed at the proximal and distal end locations of the TPVs where the devices impinge the RVOT wall. No other consistent trends were observed across simulations. The observed variability in mechanical metrics across RVOTS, stents, and locations in the RVOT highlights that no single device performs optimally in all anatomies, thereby reinforcing the need for simulation-based patient-specific assessment. Conclusions - This study demonstrates the feasibility of a novel open-source workflow for the rapid simulation of TPVR which with further refinement may inform assessment of patient candidacy and optimal device selection.

q-bio.TO

Simulation of Transcatheter Therapies for Atrioventricular Valve Regurgitation in an Open-Source Finite Element Simulation Framework

Purpose: Transcatheter edge-to-edge repair (TEER) and annuloplasty devices are increasingly used to treat mitral valve regurgitation, yet their mechanical effects and interactions remain poorly understood. This study aimed to establish an open-source finite element modeling (FEM) framework for simulating patient-specific mitral valve repairs and to evaluate how TEER, annuloplasty, and combined strategies influence leaflet coaptation and valve mechanics. Methods: Four G4 MitraClip geometries were modeled and deployed in FEBio to capture leaflet grasp and subsequent clip-leaflet motion under physiologic pressurization. CardioBand annuloplasty was simulated by reducing annular circumference via displacement-controlled boundary conditions, and Mitralign suture annuloplasty was modeled using discrete nodal constraints. Simulations were performed for prolapse and dilated annulus cases. Valve competence (regurgitant orifice area, ROA), coaptation/contact area (CA), and leaflet stress and strain distributions were quantified. Results: In prolapse, TEER restored coaptation but increased leaflet stresses, whereas band and suture annuloplasty produced distinct valve morphologies with lower stress distributions. In dilation, TEER alone left residual regurgitation, while annuloplasty improved closure. Combined TEER & band annuloplasty minimized ROA, maximized CA, and reduced stresses relative to TEER alone, though stresses remained higher than annuloplasty alone. Conclusion: This study establishes a reproducible, open-source FEM framework for simulating transcatheter TEER and annuloplasty repairs, with the potential to be extended beyond the mitral valve. By quantifying the mechanical trade-offs of TEER, suture annuloplasty, band annuloplasty, and their combinations, this methodology highlights the potential of virtual repair to guide patient selection and optimize surgical planning.

physics.med-ph

ADEPT: A Noninvasive Method for Determining Elastic Parameters of Valve Tissue

Computer simulation of "virtual interventions" may inform optimal valve repair for a given patient prior to intervention. However, the paucity of noninvasive methods to determine in vivo mechanical parameters of valves limits the accuracy of computer prediction and their clinical application. To address this, we propose ADEPT: A noninvasive method for Determining Elastic Parameters of valve Tissue. In this work, we demonstrated its application to the tricuspid valve of a child. We first tracked valve displacements from open to closed frames within a 3D echocardiogram time sequence using image registration. Physics-informed neural networks were subsequently applied to estimate the nonlinear mechanical properties from first principles and reference displacements. The simulated model using these patient-specific parameters closely aligned with the reference image segmentation, achieving a mean symmetric distance of less than 1 mm. Our approach doubled the accuracy of the simulated model compared to the generic parameters reported in the literature.

q-bio.QM

Effect of Parametric Variation of Chordae Tendineae Structure on Simulated Atrioventricular Valve Closure

Many approaches have been used to model chordae tendineae geometries in finite element simulations of atrioventricular heart valves. Unfortunately, current "functional" chordae tendineae geometries lack fidelity that would be helpful when informing clinical decisions. The objectives of this work are (i) to improve synthetic chordae tendineae geometry fidelity to consider branching and (ii) to define how the chordae tendineae geometry affects finite element simulations of valve closure. In this work, we develop an open-source method to construct synthetic chordae tendineae geometries in the SlicerHeart Extension of 3D Slicer. The generated geometries are then used in FEBio finite element simulations of atrioventricular valve function to evaluate how variations in chordae tendineae geometry influence valve behavior. Effects are evaluated using functional and mechanical metrics. Our findings demonstrated that altering the chordae tendineae geometry of a stereotypical mitral valve led to changes in clinically relevant valve metrics and valve mechanics. Specifically, cross sectional area had the most influence over valve closure metrics, followed by chordae tendineae density, length, radius and branches. We then used this information to showcase the flexibility of our new workflow by altering the chordae tendineae geometry of two additional geometries (mitral valve with annular dilation and tricuspid valve) to improve finite element predictions. This study presents a flexible, open-source method for generating synthetic chordae tendineae with realistic branching structures. Further, we establish relationships between the chordae tendineae geometry and valve functional/mechanical metrics. This research contribution helps enrich our open-source workflow and brings the finite element simulations closer to use in a patient-specific clinical setting.

physics.med-ph

Identifying heterogeneous micromechanical properties of biological tissues via physics-informed neural networks

The heterogeneous micromechanical properties of biological tissues have profound implications across diverse medical and engineering domains. However, identifying full-field heterogeneous elastic properties of soft materials using traditional engineering approaches is fundamentally challenging due to difficulties in estimating local stress fields. Recently, there has been a growing interest in using data-driven models to learn full-field mechanical responses such as displacement and strain from experimental or synthetic data. However, research studies on inferring full-field elastic properties of materials, a more challenging problem, are scarce, particularly for large deformation, hyperelastic materials. Here, we propose a physics-informed machine learning approach to identify the elasticity map in nonlinear, large deformation hyperelastic materials. We evaluate the prediction accuracies and computational efficiency of physics-informed neural networks (PINNs) by inferring the heterogeneous elasticity maps across three materials with structural complexity that closely resemble real tissue patterns, such as brain tissue and tricuspid valve tissue. We further applied our improved architecture to three additional examples of breast cancer tissue and extended our analysis to three hyperelastic constitutive models: Neo-Hookean, Mooney Rivlin, and Gent. Our selected network architecture consistently produced highly accurate estimations of heterogeneous elasticity maps, even when there was up to 10% noise present in the training data.

math.NA

The effects of leaflet material properties on the simulated function of regurgitant mitral valves

Advances in three-dimensional imaging provide the ability to construct and analyze finite element (FE) models to evaluate the biomechanical behavior and function of atrioventricular valves. However, while obtaining patient-specific valve geometry is now possible, non-invasive measurement of patient-specific leaflet material properties remains nearly impossible. Both valve geometry and tissue properties play a significant role in governing valve dynamics, leading to the central question of whether clinically relevant insights can be attained from FE analysis of atrioventricular valves without precise knowledge of tissue properties. As such we investigated 1) the influence of tissue extensibility and 2) the effects of constitutive model parameters and leaflet thickness on simulated valve function and mechanics. We compared metrics of valve function (e.g., leaflet coaptation and regurgitant orifice area) and mechanics (e.g., stress and strain) across one normal and three regurgitant mitral valve (MV) models with common mechanisms of regurgitation (annular dilation, leaflet prolapse, leaflet tethering) of both moderate and severe degree. We developed a novel fully-automated approach to accurately quantify regurgitant orifice areas of complex valve geometries. We found that the relative ordering of the mechanical and functional metrics was maintained across a group of valves using material properties up to 15% softer than the representative adult mitral constitutive model. Our findings suggest that FE simulations can be used to qualitatively compare how differences and alterations in valve structure affect relative atrioventricular valve function even in populations where material properties are not precisely known.

physics.med-ph

Effective Data Sampling Strategies and Boundary Condition Constraints of Physics-Informed Neural Networks for Identifying Material Properties in Solid Mechanics

Material identification is critical for understanding the relationship between mechanical properties and the associated mechanical functions. However, material identification is a challenging task, especially when the characteristic of the material is highly nonlinear in nature, as is common in biological tissue. In this work, we identify unknown material properties in continuum solid mechanics via physics-informed neural networks (PINNs). To improve the accuracy and efficiency of PINNs, we developed efficient strategies to nonuniformly sample observational data. We also investigated different approaches to enforce Dirichlet boundary conditions as soft or hard constraints. Finally, we apply the proposed methods to a diverse set of time-dependent and time-independent solid mechanic examples that span linear elastic and hyperelastic material space. The estimated material parameters achieve relative errors of less than 1%. As such, this work is relevant to diverse applications, including optimizing structural integrity and developing novel materials.

cond-mat.mtrl-sci

A Computational Framework for Atrioventricular Valve Modeling using Open-Source Software

Atrioventricular valve regurgitation is a significant cause of morbidity and mortality in patients with acquired and congenital cardiac valve disease. Image-derived computational modeling of atrioventricular valves has advanced substantially over the last decade and holds particular promise to inform valve repair in small and heterogeneous populations which are less likely to be optimized through empiric clinical application. While an abundance of computational biomechanics studies have investigated mitral and tricuspid valve disease in adults, few studies have investigated application to vulnerable pediatric and congenital heart populations. Further, to date, investigators have primarily relied upon a series of commercial applications that are neither designed for image-derived modeling of cardiac valves, nor freely available to facilitate transparent and reproducible valve science. To address this deficiency, we aimed to build an open-source computational framework for the image-derived biomechanical analysis of atrioventricular valves. In the present work, we integrated an open-source valve modeling platform, SlicerHeart, and an open-source biomechanics finite element modeling software, FEBio, to facilitate image-derived atrioventricular valve model creation and finite element analysis. We present a detailed verification and sensitivity analysis to demonstrate the fidelity of this modeling in application to 3D echocardiography-derived pediatric mitral and tricuspid valve models. Our analyses achieved excellent agreement with those reported in the literature. As such, this evolving computational framework offers a promising initial foundation for future development and investigation of valve mechanics, in particular collaborative efforts targeting the development of improved repairs for children with congenital heart disease.

q-bio.TO

A new engineering theory describing oblique free surface impact by flexible plates

Consideration of slamming loads within the structural design of planning hulls is of critical importance in ensuring adequate structural performance in order to avoid potential catastrophic consequences. However, because of the intricacy in the interplay between complex fluid flows and nonlinear structural deformations that accompany the phenomenology of slamming, a general engineering theory in slamming has yet to be uncovered, and so design relies on specialized theories. In this paper, we propose one such theory for a design case that has, until now, eluded a proper description. In pursuit of this theory, we employ a specialized implicit, partitioned fluid-structural interaction (FSI) simulation approach, in order to study the underlying physical mechanisms accompanying the oblique impact of a flexible plate during water entry. In the present work, we first present validation results from flexible plate water entry experiments, to confirm the veracity of the developed FSI solver. Subsequent to validation, we carry out a series of numerical analyses, in an effort to characterize the regimes in impact force and plate out-of-plane deformations, as a function of impact velocities and plate flexural rigidity. Finally, we use our FSI solver, as a kind of "microscope", to study the mechanistic evolution of fluid flows and elastic plate deformations that occur during slamming. Based on these observations, we propose a novel, but simple engineering theory for flexible plates obliquely impacting the water free surface (e.g. high speed porpoising water craft reentry).

physics.flu-dyn

A Principled Approach to Design Using High Fidelity Fluid-Structure Interaction Simulations

A high fidelity fluid-structure interaction simulation may require many days to run, on hundreds of cores. This poses a serious burden, both in terms of time and economic considerations, when repetitions of such simulations may be required (e.g. for the purpose of design optimization). In this paper we present strategies based on (constrained) Bayesian optimization (BO) to alleviate this burden. BO is a numerical optimization technique based on Gaussian processes (GP) that is able to efficiently (with minimal calls to the expensive FSI models) converge towards some globally optimal design, as gauged using a black box objective function. In this study we present a principled design evolution that moves from FSI model verification, through a series of Bridge Simulations (bringing the verification case incrementally closer to the application), in order that we may identify material properties for an underwater, unmanned, autonomous vehicle (UUAV) sail plane. We are able to achieve fast convergence towards an optimal design, using a small number of FSI simulations (a dozen at most), even when selecting over several design parameters, and while respecting optimization constraints.

cs.CE