SearcharxivSearch

arXiv subjects

Wilfrid Poirier

Publications and source records attributed to Wilfrid Poirier.

6 recordsLinked to original sources

Near-field Dressing of Thermal Emission

Radiative heat transfer at subwavelength distances is generally understood as enhanced energy exchange mediated by photon tunnelling between neighboring bodies. While near-field interactions can dramatically increase mutual heat transfer, whether they also modify the thermal radiation emitted by the bodies themselves remains an open question. Here we experimentally show that near-field electromagnetic coupling reshapes far-field thermal emission through a distance-dependent dressed emissivity. Using a dual-probe calorimetric platform, we independently monitor the radiative balance of two borosilicate microspheres over separations ranging from 120 micrometers to a few hundred nanometers, spanning the transition from the far field to the near field. Nanowatt-resolved differential radiometry reveals asymmetric heat fluxes and a non-monotonic response of the hotter sphere, demonstrating that thermal radiation is governed not only by emitter-bath interactions but also by coupling to the surrounding photonic environment. By analyzing the total power exchanged between the coupled system and the external thermal bath, we directly extract a dressed emissivity and show that near-field interactions renormalize the far-field thermal emission of the pair through a redistribution of the electromagnetic modes available to thermal fluctuations. These observations provide direct experimental evidence that thermal emitters are dressed by their electromagnetic environment, establishing a thermal analogue of the Purcell effect.

physics.optics

A high-sensitivity resistance bridge for nanoscale thermal microscopy

Measurements of heat flux between micro-objects, in vacuum or in air, are challenging because of their small size and the low thermal conductance of the medium between them. One way to address this issue consists in using a scanning thermal microscope (SThM) equipped with a temperature dependent resistance thermometer. However, this requires an instrument able to both injecting a defined heating Joule power and performing highly-sensitive resistance measurements. Here, we present such an instrument based on a Wheatstone bridge equipped with three Kelvin arms. It can perform resistance measurements in the range from 100 $Ω$ to 1000 $Ω$ not only in direct current but also in alternating current regimes at frequencies up to a few tenths of kHz. We first show that measurements of resistance standards are accurate to within one part in $10^4$ with a relative experimental standard deviation which can be as low as one part in $10^8$ for one second measurement. The instrument is then tested with a SThM thermometer. With the support of an electro-thermal model considering thermal time constants of the thermometer, we explain the frequency dependence of detected signals and optimize the measurement protocols of temperature and heat flux. By measuring sub-mK temperature variations, this instrument is then used to determine with a few nanowatts uncertainty the near-field radiative heat flux between a heated glass microsphere and a glass substrate, which is caused by the coupling of surface phonon-polaritons.

physics.ins-det

Non-monotonic radiative heat transfer in the transition from far field to near field

We present high precision measurements of the radiative heat transfer of a glass microsphere immersed in a thermal bath in vacuum facing three different planar substrates (SiO2, SiC and Au), which exhibit very different optical behaviors in the infrared region. Using a thermoresistive probe on a cantilever, we show the nonmonotonic behavior of the radiative flux between the microsphere and its environment when the microsphere is brought closer to the substrate in the far-field to near-field transition regime. We demonstrate that this unexpected behavior is related to the singularities of dressed emission mechanisms in this three-body system sphere-substrate-bath with respect to the separation distance.

cond-mat.mes-hall

Improvements of the programmable quantum current generator for better traceability of electrical current measurements

A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improved quantum current generator is used to calibrate different ammeters with lower measurement uncertainties. Besides, measurements of its quantized current using a calibrated Ultrastable Low-Noise Current Amplifier (ULCA) have shown that the realizations of the ampere at PTB (Physikalisch-Technische Bundesanstalt) and LNE (Laboratoire national de métrologie et d'essais) in the range $\pm50$ $μ$A agreed to -3.7 parts in $10^{7}$ with a combined standard uncertainty of 3.1 parts in $10^{7}$ (coverage factor $k_\mathrm{c}=1$).

physics.ins-det

Quantitative measurement of the thermal contact resistance between a glass microsphere and a plate

Accurate measurements of the thermal resistance between micro-objects made of insulating materials are complex because of their small size, low conductivity, and the presence of various ill-defined gaps. We address this issue using a modified scanning thermal microscope operating in vacuum and in air. The sphere-plate geometry is considered. Under controlled heating power, we measure the temperature on top of a glass microsphere glued to the probe as it approaches a glass plate at room temperature with nanometer accuracy. In vacuum, a jump is observed at contact. From this jump in temperature and the modeling of the thermal resistance of a sphere, the sphere-plate contact resistance $ R_K=(1.4 \pm 0.18)\times10^7 \ \mathrm{K.W^{-1}}$ and effective radius $r=(36 \pm 4)$ nm are obtained. In air, the temperature on top of the sphere shows a decrease starting from a sphere-plate distance of 200 $\mathrm{μm}$. A jump is also observed at contact, with a reduced amplitude. The sphere-plate coupling out of contact can be described by the resistance shape factor of a sphere in front of a plate in air, placed in a circuit involving a series and a parallel resistance that are determined by fitting the approach curve. The contact resistance in air $R^*_K=(1.2 \pm 0.46)\times 10^7 \ \mathrm{K.W^{-1}}$ is then estimated from the temperature jump. The method is quantitative without requiring any tedious multiple-scale numerical simulation, and is versatile to describe the coupling between micro-objects from large distances to contact in various environments.

cond-mat.mtrl-sci

Quantum resistance standard accuracy close to the zero-dissipation state

We report on a comparison of four GaAs/AlGaAs-based quantum resistance standards using an original technique adapted from the well-known Wheatstone bridge. This work shows that the quantized Hall resistance at Landau level filling factor $ν=2$ can be reproducible with a relative uncertainty of $32\times 10^{-12}$ in the dissipationless limit of the quantum Hall effect regime. In the presence of a very small dissipation characterized by a mean macroscopic longitudinal resistivity $\bar{R_{xx}(B)}$ of a few $μΩ$, the discrepancy $ΔR_{\mathrm{H}}(B)$ measured on the Hall plateau between quantum Hall resistors turns out to follow the so-called resistivity rule $\bar{R_{xx}(B)}=αB\times d(ΔR_{\mathrm{H}}(B))/dB$. While the dissipation increases with the measurement current value, the coefficient $α$ stays constant in the range investigated ($40-120 \mathrm{μA}$). This result enlightens the impact of the dissipation emergence in the two-dimensional electron gas on the Hall resistance quantization, which is of major interest for the resistance metrology. The quantum Hall effect is used to realize a universal resistance standard only linked to the electron charge \emph{e} and the Planck's constant \emph{h} and it is known to play a central role in the upcoming revised \emph{Système International} of units. There are therefore fundamental and practical benefits in testing the reproducibility property of the quantum Hall effect with better and better accuracy.

cond-mat.mes-hall