SearcharxivSearch

arXiv subjects

Wim-Alexander Beckers

Publications and source records attributed to Wim-Alexander Beckers.

2 recordsLinked to original sources

Catheter Monitoring in Intelligent Endovascular Navigation Systems: Interactive Simulations and Mixed Reality for Enhanced Navigational Awareness

Purpose: Developing and testing a framework that integrates real-time catheter shape reconstruction, interactive simulations, and mixed reality visualization to enable accurate monitoring of catheter-vessel interactions during endovascular navigation. Methods: A finite element model (FEM) of the venous pathway from the right femoral vein to the inferior vena cava was generated from computed tomography data and implemented into an interactive simulation. Catheter motion was imposed as boundary condition, and catheter-vessel contact was modeled with a Lagrange multiplier formulation to compute vessel deformation. The framework was tested in-vitro using a sensorized catheter with Fiber Bragg Grating and electromagnetic sensors as it was advanced through a silicone replica of the vascular anatomy. Real-time sensor read-outs fed the simulation, and the updated catheter and vessel geometries were streamed to Hololens 2. The performance and accuracy of FEM-computed vessel wall displacement were validated against experimental ground-truth obtained via stereo frames triangulation. Results: The simulated time exceeded the real temporal extent by 12% during initial navigation and by 45% when the catheter reached the most tortuous portion. Hololens 2 rendering remained stable at 35-40 frames per second. The median relative displacement error between FEM-computed and ground-truth vessel wall displacements remained below 1 mm and 2.33 mm for these two phases, respectively. Conclusion: The study demonstrates the feasibility of integrating interactive biomechanical simulation with real-time sensor data to enable continuous monitoring of catheter-vessel interactions, with mixed reality visualization serving as a user interface to support operator decision-making.

cs.HC

Force-Displacement Profiling for Robot-Assisted Deployment of a Left Atrial Appendage Occluder Using FBG-EM Distal Sensing

Atrial fibrillation (AF) increases the risk of thromboembolic events due to impaired function of the left atrial appendage (LAA). Left atrial appendage closure (LAAC) is a minimally invasive intervention designed to reduce stroke risk by sealing the LAA with an expandable occluder device. Current deployment relies on manual catheter control and imaging modalities like fluoroscopy and transesophageal echocardiography, which carry limitations including radiation exposure and limited positioning precision. In this study, we leverage a previously developed force-sensing delivery sheath integrating fiber Bragg gratings (FBGs) at the interface between the catheter and the occluder. Combined with electromagnetic (EM) tracking, this setup enables real-time measurement of interaction forces and catheter tip position during robot-assisted LAAC deployment in an anatomical phantom. We present a novel force-displacement profiling method that characterizes occluder deployment dynamics and identifies key procedural steps without relying on ionizing radiation. The force profiles reveal low-magnitude interaction forces, suggesting minimal mechanical stress on the surrounding anatomy. This approach shows promise in providing clinicians with enhanced intraoperative feedback, improving deployment outcome. Future work will focus on automating deployment steps classification and validating the sensing strategy in dynamic, realistic environments.

cs.RO