SearcharxivSearch

arXiv subjects

Winfried Kockelmann

Publications and source records attributed to Winfried Kockelmann.

2 recordsLinked to original sources

Single-exposure elemental differentiation and texture-sensitive phase-retrieval imaging with a neutron counting micro-channel plate detector

Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility of multimodal analysis including total neutron cross-section spectra measurements, quantitative material differentiation imaging and texture-sensitive in-line phase imaging, from a single exposure using an MCP detector. This multimodal approach operates in full-field imaging mode, with the neutron transmission spectra acquired at each individual detector pixel. Due to the polychromatic nature of the beam and spectroscopic resolving capability of the detector, no energy scanning is required. Good agreement with the library reference data is demonstrated for neutron cross-section spectra measurements. Two different images corresponding to two selected energy bandwidths are used for elemental differentiation imaging. Moreover, the presence of changes in texture, i.e., preferred grain orientation, in the sample is identified from our phase-retrieval imaging results.

cond-mat.mtrl-sci

Revisiting neutron propagation-based phase contrast imaging and tomography: use of phase retrieval to amplify the effective degree of brilliance

Propagation-based neutron phase-contrast tomography was demonstrated using the ISIS pulsed spallation source. The proof-of-concept tomogram with Paganin-type phase-retrieval filter applied exhibited an effective net boost of $23\pm 1$ in the signal-to-noise ratio as compared to an attenuation-based tomogram, implying a boost in the effective degree of neutron brilliance of over two orders of magnitude. This comparison is for phase retrieval versus conventional absorption with no additional collimation in place. Expressions are provided for the optimal phase-contrast geometry as well as conditions for the validity of the method. The underpinning theory is derived under the assumption of the sample being composed of a single material. The effective boost in brilliance may be employed to give reduced acquisition time, or may instead be used to keep exposure times fixed while improving the measured contrast.

eess.IV