Searcharxiv⌕ Search

arXiv subjects

Wolfgang Treberer-Treberspurg

Publications and source records attributed to Wolfgang Treberer-Treberspurg.

2 recordsLinked to original sources

Radiation effects and noise evolution in NewAthena WFI flight-production sensors

The Wide Field Imager (WFI), one of the two instruments on ESA's next large X-ray observatory NewAthena, is designed for imaging spectroscopy in the 0.2-15 keV range, combining a large field of view with high count-rate capability. Its focal plane is equipped with back-illuminated DEPFET (Depleted p-channel field-effect transistor) sensors that offer high radiation tolerance and provide near Fano-limited energy resolution. Achieving this performance requires an exceptionally low readout noise, with about 3 electrons ENC expected at beginning of life. Consequently, the devices are highly sensitive to radiation-induced changes in noise behavior. In this work, we investigate the impact of both total non-ionizing dose (TNID) and total ionizing dose (TID) on the relevant noise components, including their temperature dependence. A detector module containing a 64x64-pixel sensor from a flight-production wafer was irradiated with 62.4 MeV protons at the MedAustron accelerator facility in Wiener Neustadt to a total dose equivalent to 2.6 $\cdot$ 10$^9$ 10-MeV-protons/cm$^2$. The detector was fully biased and operated throughout the irradiation and subsequent measurements, maintaining the nominal operating temperature of 213 K. To study short-term annealing behavior at low temperature, a second, identical module was exposed to a comparable proton dose within a much shorter timescale by exploiting the available high beam flux. TID effects were investigated separately by irradiating another device with 17.4 keV Mo-K_alpha X-rays to a total dose of 15 Gy. We report the resulting changes in readout noise, dark current, and threshold voltage, and compare them with results from an earlier irradiation campaign using pre-flight sensors. Implications for the instrument's required operating temperature and its expected end-of-life performance are discussed.

astro-ph.IM↗

Low temperature proton irradiation with DEPFETs for Athena's Wide Field Imager

The Wide Field Imager (WFI), one of two instruments on ESA's next large X-ray mission Athena, is designed for imaging spectroscopy of X-rays in the range of 0.2 to 15 keV with a large field of view and high count rate capability. The focal plane consists of back-illuminated DEPFET (Depleted p-channel field effect transistor) sensors that have a high radiation tolerance and provide a near Fano-limited energy resolution. To achieve this, a very low noise readout is required, about 3 electrons ENC at beginning of life is foreseen. This makes the device very susceptible to any radiation induced worsening of the readout noise. The main mechanism of degradation will be the increase of dark current due to displacement damage caused primarily by high energy protons. To study the expected performance degradation, a prototype detector module with fully representative pixel layout and fabrication technology was irradiated with 62.4 MeV protons at the accelerator facility MedAustron in Wiener Neustadt. A total dose equivalent to 3.3 $\textstyle{10^{9}}$ 10-MeV protons/$\mathrm{cm^{2}}$ was applied in two steps. During, in-between and after the irradiations the detector remained at the operating temperature of 213 K and was fully biased and operated. Data was recorded to analyze the signal of all incident particles. We report on the increase of dark current after the irradiation and present the current related damage rate at 213 K. The effect of low temperature annealing at 213 K , 236 K, 253 K, 273 K, and 289 K is presented.

astro-ph.IM↗