SearcharxivSearch

arXiv subjects

Woohyun Chung

Publications and source records attributed to Woohyun Chung.

18 recordsLinked to original sources

Multi-tesla operation of high-temperature superconducting cavities for accelerated axion dark matter searches

Axion haloscopes use radio-frequency cavities immersed in a magnetic field to search for dark-matter axions, which could resolve two central puzzles in fundamental physics: the strong charge-parity problem in quantum chromodynamics and the nature of dark matter. Multi-tesla fields trigger axion-to-photon conversion but induce severe vortex dissipation in standard superconductors, whereas copper cavities are limited by the anomalous skin effect ($Q \lesssim 10^5$). Here, we overcome these barriers by introducing a pole-to-pole 3-dimensional cavity architecture constructed from strain-controlled, mechanically delaminated rare-earth barium copper oxide (REBCO) tapes. By selectively stripping the lossy metallic substrate while utilizing the copper stabilizer as a "conductive backing" we convert the longitudinal assembly gaps into waveguides below cutoff, effectively suppressing cross-seam RF leakage. Employing a two-track strategy, we first unveiled the intrinsic high-field potential of the material with a 5.4 GHz resonant cavity, achieving an unloaded quality-factor ($Q_0$) of $1.4 \times 10^7$ in an 8 T magnetic field, exceeding conventional copper baselines by two orders of magnitude. Second, prioritizing practical haloscope integration, we engineered a tunable, volume-maximized 2.3 GHz pathfinder cavity. Deployed in the Pilot Axion Cavity Experiment at the Center for Axion and Precision Physics Research (CAPP-PACE), this system achieved a 180 mK noise temperature and a 5-fold $Q$ enhancement over copper, cumulatively delivering a $\sim$8.4-fold scan-rate acceleration.

hep-ex

Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz

We report a follow-up axion haloscope search near 1.036 GHz that completes and extends our previous work [Phys. Rev. X 14, 031023 (2024)], in which a portion of the HEMT-based data could not be analyzed due to unrecorded experimental information. While recovering this dataset, we identified an excess near 1.036 GHz that satisfied our candidate-selection criteria, motivating dedicated validation studies, including independent cross-checks and re-examination with the original apparatus. The excess did not persist under these investigations and was not confirmed as an axion dark-matter signal. We subsequently extended the search over a 20-MHz band surrounding the candidate using a quantum-noise-limited amplifier, achieving sensitivity close to the Dine-Fischler-Srednicki-Zhitnitsky benchmark. In the absence of a confirmed signal, we set improved 90% confidence-level upper limits on the axion-photon coupling over the frequency range 1.026-1.045 GHz. This work highlights the importance of robust candidate-validation strategies as haloscope searches approach discovery-level sensitivity.

hep-ex

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$μ$eV) to 1.185\,GHz (4.91\,$μ$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

hep-ex

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $μ$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $μ$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $ρ_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $μ$eV at a 90% confidence level.

hep-ex

Four-channel System for Characterization of Josephson Parametric Amplifiers

The axion search experiments based on haloscopes at the Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) in South Korea are performed in the frequency range from 1 GHz to 6 GHz. In order to perform the experiments in a strong magnetic field of 12 T and a large-volume cavity of close to 40 liters, we use He wet dilution refrigerators with immersed superconducting magnets. The measurements require continuous operation for months without interruptions for microwave component replacements. This is achieved by using different cryogenic engineering approaches including microwave RF-switching. The critical components, defining the scanning rate and the sensitivity of the setup, are the Josephson parametric amplifiers (JPA) and cryogenic low noise amplifiers (cLNA) based on high-electron-mobility-transistor (HEMT) technology. It is desirable for both devices to have a wide frequency range and low noise close to the quantum limit for the JPA. In this paper, we show a recent design of a 4-channel measurement setup for JPA and HEMT measurements. The setup is based on a 4-channel wideband noise source (NS) and is used for both JPA and HEMT gain and noise measurements. The setup is placed at 20 mK inside the dry dilution refrigerator. The NS is thermally decoupled from the environment using plastic spacers, superconducting wires and superconducting coaxial cables. We show the gain and noise temperature curves measured for 4 HEMT amplifiers and 2 JPAs in one cool-down

cond-mat.supr-con

CAPP Axion Search Experiments with Quantum Noise Limited Amplifiers

The axion is expected to solve the strong CP problem of quantum chromodynamics and is one of the leading candidates for dark matter. CAPP in South Korea has several axion search experiments based on cavity haloscopes in the frequency range of 1-6 GHz. The main effort focuses on operation of the experiments with the highest possible sensitivity. It requires maintenance of the haloscopes at the lowest physical temperature in the range of mK and usage of low noise components to amplify the weak axion signal. We report development and operation of low noise amplifiers for 5 haloscope experiments targeting at different frequency ranges. The amplifiers show noise temperatures approaching the quantum limit.

cond-mat.supr-con

Josephson Parametric Amplifier in Axion Experiments

The axion is a hypothetical particle, a promising candidate for dark matter, and a solution to the strong CP problem. Axion haloscope search experiments deal with a signal power comparable to noise uncertainty at millikelvin temperature. We use a flux-driven Josephson parametric amplifier (JPA) with the aim of approaching a noise level near the theoretically allowed limit of half quanta. In our measurements to characterize the JPA we have found the added noise to the system with a JPA as the first-stage amplifier to be lower than 110 mK at the frequencies from 0.938 GHz to 0.963 GHz.

cond-mat.supr-con

Axion Dark Matter Search around 4.55 $μ$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{aγγ}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $μ$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex

Near-Quantum-Noise Axion Dark Matter Search at CAPP around 9.5 $μ$eV

We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 $μ$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivity than existing limits.

hep-ex

First Results from Axion Haloscope at CAPP around 10.7 $μ$eV

The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

hep-ex

First prototype of a biaxially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ microwave cavity in a high magnetic field for dark matter axion search

A high-quality factor microwave resonator in the presence of a strong magnetic field could have a wide range of applications, such as axion dark matter searches where the two aspects must coexist to enhance the experimental sensitivity. We introduce a polygon-shaped cavity design with bi-axially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ superconducting tapes covering the entire inner wall. Using a 12-sided polygon cavity, we obtain substantially improved quality factors of the TM$_{010}$ mode at 6.9 GHz at 4 K with respect to a copper cavity and observe no considerable degradation in the presence of magnetic fields up to 8 T. This corresponds to the first demonstration of practical applications of superconducting radio frequency technology for axion and other research areas requiring low loss in a strong magnetic field. We address the importance of the successful demonstration and discuss further improvements.

physics.ins-det

Characterization of a flux-driven Josephson parametric amplifier with near quantum-limited added noise for axion search experiments

The axion, a hypothetical elementary pseudoscalar, is expected to solve the strong CP problem of QCD and is also a promising candidate for dark matter. The most sensitive axion search experiments operate at millikelvin temperatures and hence rely on instrumentation that carries signals from a system at cryogenic temperatures to room temperature instrumentation. One of the biggest limiting factors affecting the parameter scanning speed of these detectors is the noise added by the components in the signal detection chain. Since the first amplifier in the chain limits the minimum noise, low-noise amplification is of paramount importance. This paper reports on the operation of a flux-driven Josephson parametric amplifier (JPA) operating at around 2.3 GHz with added noise approaching the quantum limit. The JPA was employed as a first stage amplifier in an experimental setting similar to the ones used in haloscope axion detectors. By operating the JPA at a gain of 19 dB and cascading it with two cryogenic amplifiers operating at 4 K, noise temperatures as low as 120 mK were achieved for the whole signal detection chain.

cond-mat.supr-con

Superconducting cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be used in a wide range of applications, especially for enhancing the scanning speed in axion dark matter research. In this letter, we introduce a polygon-shaped resonant cavity with commercial YBCO tapes covering the entire inner wall. We demonstrated that the maximum Q-factor (TM$_{010}$, 6.93 GHz) of the superconducting YBCO cavity was about 6 times higher than that of a copper cavity and showed no significant degradation up to 8 T at 4 K. This is the first indication of the possible applications of HTS technology to the research areas requiring low loss in a strong magnetic field at high radio frequencies.

physics.app-ph

Exploiting higher-order resonant modes for axion haloscopes

The haloscope is one of the most sensitive approaches to the QCD axion physics within the region where the axion is considered to be a dark matter candidate. Current experimental sensitivities, which rely on the lowest fundamental TM010 mode of a cylindrical cavity, are limited to relatively low mass regions. Exploiting higher-order resonant modes would be beneficial because it will enable us to extend the search range with no volume loss and higher quality factors. This approach has been discarded mainly because of the significant degradation of form factor, and difficulty with frequency tuning. Here we introduce a new tuning mechanism concept which both enhances the form factor and yields reasonable frequency tunability. A proof of concept demonstration verified that this design is feasible for high mass axion search experiments.

physics.ins-det

Axion Dark Matter Research with IBS/CAPP

The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.

physics.ins-det

Maintaining high Q-factor of superconducting YBa$_2$Cu$_3$O$_{7-x}$ microwave cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be of great use in a wide range of fields, from accelerator design to axion dark matter search. The natural choice of material for the superconducting cavity to be placed in a high field is a high temperature superconductor (HTS) with a high critical field. The deposition, however, of a high-quality, grain-aligned HTS film on a three-dimensional surface is technically challenging. We have fabricated a polygon-shaped resonant cavity with commercial YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) tapes covering the entire inner wall and measured the Q-factor at 4 K at 6.93 GHz as a function of an external DC magnetic field. We demonstrated that the high Q-factor of the superconducting YBCO cavity showed no significant degradation from 1 T up to 8 T. This is the first indication of the possible applications of HTS technology to the research areas requiring a strong magnetic field at high radio frequencies.

physics.ins-det

High Quality Factor High-Temperature Superconducting Microwave Cavity Development for the Dark Matter Axion Search in a Strong Magnetic Field

We demonstrate a superconducting (SC) microwave (mw) cavity that can accelerate the dark matter search by maintaining superconductivity in a high DC magnetic field. We used high-temperature superconductor (HTSC) yttrium barium copper oxide (YBCO) with a phase transition temperature of 90K to prevent SC failure by the magnetic field. Since the direct deposition of HTSC film on the metallic mw cavity is very difficult, we used the commercial HTSC tapes which are flexible metallic tapes coated with HTSC thin films. We fabricated resonating cavity ($f_{TM010}$ ~ 6.89 GHz) with a third of the inner wall covered by YBCO tapes and measured the quality factor (Q factor) at 4K temperature, varying the DC magnetic field from 0 to 8 tesla. There was no significant quality (Q) factor drop and the superconductivity was well maintained even in 8 tesla magnetic field. This implies the possibility of good performance of HTSC mw resonant cavity under a strong magnetic field for axion detection.

physics.ins-det

Search for PQ Axions

A major fraction of the mass content of the universe is composed of dark matter (DM), i.e. particles not interacting significantly with electromagnetic radiation, with ordinary matter or self-interacting (cold dark matter). The axion is originally proposed to solve the strong CP problem of quantum chromodynamics, but now emerges as an excellent cold DM candidate. The physics case of these particles has been considerably developed in recent years, and there are now useful guidelines and powerful motivations to attempt experimental detection. Admittedly, the lack of a positive signal of new physics at the high energy frontier, and in underground detectors searching for weakly interacting massive particles, is also contributing to the increase of interest in axion searches. The experimental landscape is rapidly evolving, with many novel detection concepts and new experimental proposals. The lastest development of the axion search efforts will be discussed.

hep-ex