An Instrument for Physical Vapor Deposition onto Cryo-EM Samples for Microsecond Time-Resolved Cryo-EM

Laser flash melting and revitrification experiments have recently improved the time resolution of cryo-electron microscopy (cryo-EM) to the microsecond timescale, making it fast enough to observe many of the protein motions that are associated with function. The technique has also opened up a new dimension for cryo-EM sample preparation, making it possible to deposit compounds onto a cryo-EM sample while it is frozen, so that upon flash melting, the embedded particles experience an altered environment. For example, we have recently shown that depositing ultrathin silicon dioxide membranes onto a cryo-EM sample causes particles to detach from the interface upon flash melting, removing preferred particle orientation. These experiments also point towards a new strategy for initiating protein dynamics in time resolved experiments by depositing reagents, which will then mix with the sample upon flash melting. Here, we describe an apparatus for physical vapor deposition of compounds onto cryo-EM samples, detailing its design and operation. As a demonstration, we determine that the minimum thickness of silicon dioxide sealing membranes in a laser flash melting experiment is just over two monolayers. We propose that our design can form the basis for an integrated platform for microsecond time-resolved cryo-EM experiments.

physics.ins-det↗

Wehnelt Photoemission in an Ultrafast Electron Microscope: Stability and Usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a 0.1-mm diameter LaB6 source with graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a 0.2-mm diameter polycrystalline Ta source. For each cathode type and configuration, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Further, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB6 thermionic emission, as well as to on-axis photoemission. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be within 1% of the mean for 70 minutes (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition was also found to be within 1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

cond-mat.mtrl-sci↗