SearcharxivSearch

arXiv subjects

Wyatt Adams

Publications and source records attributed to Wyatt Adams.

9 recordsLinked to original sources

Experimental realization of the active convolved illumination imaging technique for enhanced signal-to-noise ratio

Imaging is indispensable for nearly every field of science, engineering, technology, and medicine. However, measurement noise and stochastic distortions pose fundamental limits to accessible spatiotemporal information despite impressive tools such as SIM, PALM/STORM, and STED microscopy. How to combat this challenge ideally has been an open question for decades. Inspired by a "virtual gain" technique to compensate losses in metamaterials, "active convolved illumination" has been recently proposed to significantly improve the signal-to-noise ratio, hence data acquisition. In this technique, the light pattern of the object is superimposed with a correlated auxiliary pattern, the function of which is to reverse the adverse effect of noise and random distortion based on their spectral characteristics. Despite enormous implications in statistics, an experimental realization of this novel technique has been lacking to date. Here, we present the first experimental demonstration. We find that the active convolved illumination does not only boost the resolution limit and image contrast, but also the resistance to pixel saturation. The results confirm the previous theories and opens up new horizons in a wide range of disciplines from atmospheric sciences, seismology, biology, statistical learning, and information processing to quantum noise beyond the fundamental boundaries.

physics.optics

Theory of coherent active convolved illumination for superresolution enhancement

Recently an optical amplification process called the plasmon injection scheme was introduced as an effective solution to overcoming losses in metamaterials. Implementations with near-field imaging applications have indicated substantial performance enhancements even in the presence of noise. This powerful and versatile compensation technique, which has since been renamed to a more generalized active convolved illumination, offers new possibilities of improving the performance of many previously conceived metamaterial-based devices and conventional imaging systems. In this work, we present the first comprehensive mathematical breakdown of active convolved illumination for coherent imaging. Our analysis highlights the distinctive features of active convolved illumination, such as selective spectral amplification and correlations, and provides a rigorous understanding of the loss compensation process. These features are achieved by an auxiliary source coherently superimposed with the object field. The auxiliary source is designed to have three important properties. First, it is correlated with the object field. Second, it is defined over a finite spectral bandwidth. Third, it is amplified over that selected bandwidth. We derive the variance for the image spectrum and show that utilizing the auxiliary source with the above properties can significantly improve the spectral signal-to-noise ratio and resolution limit. Besides enhanced superresolution imaging, the theory can be potentially generalized to the compensation of information or photon loss in a wide variety of coherent and incoherent linear systems including those, for example, in atmospheric imaging, time-domain spectroscopy, ${\cal PT}$ symmetric non-Hermitian photonics, and even quantum computing.

physics.optics

Plasmonic Superlens Imaging Enhanced by Incoherent Active Convolved Illumination

We introduce a loss compensation method to increase the resolution of near-field imaging with a plasmonic superlens that relies on the convolution of a high spatial frequency passband function with the object. Implementation with incoherent light removes the need for phase information. The method is described theoretically and numerical imaging results with artificial noise are presented, which display enhanced resolution of a few tens of nanometers, or around one-fifteenth of the free space wavelength. A physical implementation of the method is designed and simulated to provide a proof-of-principle, and steps toward experimental implementation are discussed.

physics.optics

Enhanced superlens imaging with loss-compensating hyperbolic near-field spatial filter

Recently a coherent optical process called plasmon injection ($Π$) scheme, which employs an auxiliary source, has been introduced as a new technique to compensate losses in metamaterials. In this work, a physical implementation of the $Π$ scheme on a thin silver film is proposed for enhanced superlens imaging. The efficacy of the scheme is illustrated by enhancing near-field imaging deeper beyond the diffraction limit in the presence of absorption losses and noise. The auxiliary source is constructed by a high-intensity illumination of the superlens integrated with a near-field spatial filter. The integrated system enables reconstruction of an object previously unresolvable with the superlens alone. This work elevates the viability of the $Π$ scheme as a strong candidate for loss compensation in near-field imaging systems without requiring non-linear effects or gain medium.

physics.optics

Hyperbolic metamaterial as a tunable near-field spatial filter for the implementation of the active plasmon injection loss compensation scheme

We present how to physically realize the auxiliary source described in the recently introduced active plasmon injection loss compensation scheme for enhanced near-field superlensing. Particularly, we show that the characteristics of the auxiliary source described in the active plasmon injection scheme including tunable narrow-band and selective amplification via convolution can be realized by using a hyperbolic metamaterial functioning as a near-field spatial filter. Besides loss compensation, the proposed near-field spatial filter can be useful for real-time high resolution edge detection.

physics.optics

Active plasmon injection scheme for subdiffraction imaging with imperfect negative index flat lens

We present an active physical implementation of the recently introduced plasmon injection loss compensation scheme for Pendry's non-ideal negative index flat lens in the presence of realistic material losses and signal-dependent noise. In this active implementation, we propose to use a physically convolved external auxiliary source for signal amplification and suppression of the noise in the imaging system. In comparison with the previous passive implementations of the plasmon injection scheme for sub-diffraction limited imaging, where an inverse filter post-processing is used, the active implementation proposed here allows for deeper subwavelength imaging far beyond the passive post-processing scheme by extending the loss compensation to even higher spatial frequencies.

physics.optics

Perfect compensation of absorption in metamaterials for diffraction-unlimited imaging

To overcome the resolution limit of conventional optics, near field imaging techniques using a negative index flat lens (NIFL) have been previously developed that amplify the evanescent components of the incident field. Here, a technique is developed and demonstrated to compensate for losses in a non-ideal NIFL by determining the transfer function of the lens and subsequently applying the inverse to the unresolved raw image. The result is a compensated image with sub-diffraction-limited resolution.

physics.optics

Enhancing the resolution of hyperlens by the compensation of losses without gain media

We present a method to improve the resolution of available hyperlenses in the literature. In this method, we combine the operation of hyperlens with the recently proposed plasmon injection scheme for loss compensation in metamaterials. Image of an object, which is otherwise not resolvable by the hyperlens alone, was reconstructed up to the minimum feature size of one seventh of the free-space wavelength.

physics.optics

Bringing the 'perfect lens' into focus by near-perfect compensation of losses without gain media

In this paper, the optical properties and imaging performance of a non-ideal Pendry's negative index flat lens with a practical value for loss are studied. Analytical calculations of the optical properties of the lens are performed, and those results are used to further study the lens and corresponding imaging system numerically. The plasmon injection scheme for loss compensation in negative index metamaterials is applied to the results from the imaging system, resulting in a perfect reconstruction of a previously unresolved image that demonstrates sub-diffraction-limit resolution.

physics.optics