SearcharxivSearch

arXiv subjects

X. Bertou

Publications and source records attributed to X. Bertou.

At least 19 recordsLinked to original sources

Constraints on Sub-MeV Dark Matter from Solar Reflection with DAMIC-M

The Sun acts as a natural dark matter accelerator. Galactic halo particles scattering in the solar plasma emerge with velocities well beyond the Galactic escape speed, providing a boosted flux that extends the kinematic reach of direct detection experiments into the sub-MeV mass regime. We present constraints on solar-reflected dark matter (SRDM) from the DAMIC-M prototype detector using $\sim$1.3~kg-day of data acquired with silicon skipper charge coupled devices (CCDs) at the Modane Underground Laboratory. Exploiting the spatial diffusion signature of low-energy electron recoils, we derive 90% C.L. upper limits on the DM-electron scattering cross section for both heavy- and ultralight-mediator benchmarks, reaching $\bar{\sigma}_e\sim 3.16 \cdot 10^{-37} \rm{cm^2}$ at $0.1$ MeV. For the ultralight mediator, our limits are competitive with the world-leading constraints, achieved with an integrated exposure of $\sim1.3$~kg-day. These results probe the parameter space between stellar-cooling bounds and terrestrial limits from standard halo searches, a region inaccessible to direct detection experiments relying solely on the standard halo flux.

hep-ex

Daily Modulation Constraints on Light Dark Matter with DAMIC-M

The flux of Hidden Sector particles from the Galactic halo reaching an underground detector can be significantly attenuated by interactions within the Earth for sufficiently large scattering crosssections. This attenuation gives rise to a characteristic daily modulation in the detection rate, due to Earth's rotation. We present results from a search for such a modulation using a 1.257 kg-day dataset collected with the DAMIC-M Low Background Chamber. A model-independent analysis reveals no significant modulation in the 1e- event rate over periods from 1 to 48 h, highlighting the excellent temporal stability of the detector. In a complementary model-dependent analysis, we target the expected daily modulation signature of Hidden Sector particles, with masses in the range [0.53,2] MeV/c2, interacting with electrons via a dark photon mediator. By leveraging the expected temporal evolution of the signal, we set improved constraints on Dark Matter masses below 1.2 MeV/c2, surpassing our previous limits.

hep-ex

First Production of Skipper-CCD Modules for the DAMIC-M Experiment

The DAMIC-M experiment will search for sub-GeV dark matter particles with a large array of silicon skipper charge-coupled devices (CCDs) at the Modane Underground Laboratory (LSM) in France. After five years of development, we recently completed the production of 28 CCD modules at the University of Washington, each consisting of four 9-megapixel skipper CCDs. Material screening and background controls were implemented to meet stringent radio-purity targets, while extensive testing was employed to select science-grade CCDs for the modules and confirm their excellent performance after fabrication. Further testing at LSM will select 26 of these modules (${\sim}$350 g active mass) to be installed and operated in the DAMIC-M detector in early 2026.

physics.ins-det

Probing Benchmark Models of Hidden-Sector Dark Matter with DAMIC-M

We report on a search for sub-GeV dark matter (DM) particles interacting with electrons using the DAMIC-M prototype detector at the Modane Underground Laboratory. The data feature a significantly lower detector single $e^-$ rate (factor 50) compared to our previous search, while also accumulating a ten times larger exposure of $\sim$1.3 kg-day. DM interactions in the skipper charge-coupled devices (CCDs) are searched for as patterns of two or three consecutive pixels with a total charge between 2 and 4 $e^-$. We find 144 candidates of 2 $e^-$ and 1 candidate of 4 $e^-$, where 141.5 and 0.071, respectively, are expected from background. With no evidence of a DM signal, we place stringent constraints on DM particles with masses between 1 and 1000 MeV/$c^2$ interacting with electrons through an ultra-light or heavy mediator. For large ranges of DM masses below 1 GeV/c$^2$, we exclude theoretically-motivated benchmark scenarios where hidden-sector particles are produced as a major component of DM in the Universe through the freeze-in or freeze-out mechanisms.

hep-ex

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

The Pierre Auger Observatory Open Data

The Pierre Auger Collaboration has embraced the concept of open access to their research data since its foundation, with the aim of giving access to the widest possible community. A gradual process of release began as early as 2007 when 1% of the cosmic-ray data was made public, along with 100% of the space-weather information. In February 2021, a portal was released containing 10% of cosmic-ray data collected from 2004 to 2018, during Phase I of the Observatory. The Portal included detailed documentation about the detection and reconstruction procedures, analysis codes that can be easily used and modified and, additionally, visualization tools. Since then the Portal has been updated and extended. In 2023, a catalog of the 100 highest-energy cosmic-ray events examined in depth has been included. A specific section dedicated to educational use has been developed with the expectation that these data will be explored by a wide and diverse community including professional and citizen-scientists, and used for educational and outreach initiatives. This paper describes the context, the spirit and the technical implementation of the release of data by the largest cosmic-ray detector ever built, and anticipates its future developments.

astro-ph.HE

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.

hep-ex

Confirmation of the spectral excess in DAMIC at SNOLAB with skipper CCDs

We present results from a 3.25 kg-day target exposure of two silicon charge-coupled devices (CCDs), each with 24 megapixels and skipper readout, deployed in the DAMIC setup at SNOLAB. With a reduction in pixel readout noise of a factor of 10 relative to the previous detector, we investigate the excess population of low-energy events in the CCD bulk previously observed above expected backgrounds. We address the dominant systematic uncertainty of the previous analysis through a depth fiducialization designed to reject surface backgrounds on the CCDs. The measured bulk ionization spectrum confirms the presence of an excess population of low-energy events in the CCD target with characteristic rate of ${\sim}7$ events per kg-day and electron-equivalent energies of ${\sim}80~$eV, whose origin remains unknown.

astro-ph.CO

First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e$^-$. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/$c^2$, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/$c^2$ and [1.5,15.1] MeV/$c^2$ for ultralight and heavy mediator interactions, respectively.

hep-ex

A Catalog of the Highest-Energy Cosmic Rays Recorded During Phase I of Operation of the Pierre Auger Observatory

A catalog containing details of the highest-energy cosmic rays recorded through the detection of extensive air-showers at the Pierre Auger Observatory is presented with the aim of opening the data to detailed examination. Descriptions of the 100 showers created by the highest-energy particles recorded between 1 January 2004 and 31 December 2020 are given for cosmic rays that have energies in the range 78 EeV to 166 EeV. Details are also given of a further nine very-energetic events that have been used in the calibration procedure adopted to determine the energy of each primary. A sky plot of the arrival directions of the most energetic particles is shown. No interpretations of the data are offered.

astro-ph.HE

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $γ$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $γ$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.

physics.ins-det

The energy spectrum of cosmic rays beyond the turn-down around $10^{17}$ eV as measured with the surface detector of the Pierre Auger Observatory

We present a measurement of the cosmic-ray spectrum above 100\,PeV using the part of the surface detector of the Pierre Auger Observatory that has a spacing of 750~m. An inflection of the spectrum is observed, confirming the presence of the so-called \emph{second-knee} feature. The spectrum is then combined with that of the 1500\,m array to produce a single measurement of the flux, linking this spectral feature with the three additional breaks at the highest energies. The combined spectrum, with an energy scale set calorimetrically via fluorescence telescopes and using a single detector type, results in the most statistically and systematically precise measurement of spectral breaks yet obtained. These measurements are critical for furthering our understanding of the highest energy cosmic rays.

astro-ph.HE

Testing effects of Lorentz invariance violation in the propagation of astroparticles with the Pierre Auger Observatory

Lorentz invariance violation (LIV) is often described by dispersion relations of the form $E_i^2=m_i^2+p_i^2+δ_{i,n} E^{2+n}$ with delta different based on particle type $i$, with energy $E$, momentum $p$ and rest mass $m$. Kinematics and energy thresholds of interactions are modified once the LIV terms become comparable to the squared masses of the particles involved. Thus, the strongest constraints on the LIV coefficients $δ_{i,n}$ tend to come from the highest energies. At sufficiently high energies, photons produced by cosmic ray interactions as they propagate through the Universe could be subluminal and unattenuated over cosmological distances. Cosmic ray interactions can also be modified and lead to detectable fingerprints in the energy spectrum and mass composition observed on Earth. The data collected at the Pierre Auger Observatory are therefore possibly sensitive to both the electromagnetic and hadronic sectors of LIV. In this article, we explore these two sectors by comparing the energy spectrum and the composition of cosmic rays and the upper limits on the photon flux from the Pierre Auger Observatory with simulations including LIV. Constraints on LIV parameters depend strongly on the mass composition of cosmic rays at the highest energies. For the electromagnetic sector, while no constraints can be obtained in the absence of protons beyond $10^{19}$ eV, we obtain $δ_{γ,0} > -10^{-21}$, $δ_{γ,1} > -10^{-40}$ eV$^{-1}$ and $δ_{γ,2} > -10^{-58}$ eV$^{-2}$ in the case of a subdominant proton component up to $10^{20}$ eV. For the hadronic sector, we study the best description of the data as a function of LIV coefficients and we derive constraints in the hadronic sector such as $δ_{\mathrm{had},0} < 10^{-19}$, $δ_{\mathrm{had},1} < 10^{-38}$ eV$^{-1}$ and $δ_{\mathrm{had},2}< 10^{-57}$ eV$^{-2}$ at 5$σ$ CL.

astro-ph.HE

PlomBOX -- development of a low-cost CMOS device for environmental monitoring

This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of developing the electronics for the PlomBOX and on the first prototype.

physics.ins-det

Extraction of the Muon Signals Recorded with the Surface Detector of the Pierre Auger Observatory Using Recurrent Neural Networks

The Pierre Auger Observatory, at present the largest cosmic-ray observatory ever built, is instrumented with a ground array of 1600 water-Cherenkov detectors, known as the Surface Detector (SD). The SD samples the secondary particle content (mostly photons, electrons, positrons and muons) of extensive air showers initiated by cosmic rays with energies ranging from $10^{17}~$eV up to more than $10^{20}~$eV. Measuring the independent contribution of the muon component to the total registered signal is crucial to enhance the capability of the Observatory to estimate the mass of the cosmic rays on an event-by-event basis. However, with the current design of the SD, it is difficult to straightforwardly separate the contributions of muons to the SD time traces from those of photons, electrons and positrons. In this paper, we present a method aimed at extracting the muon component of the time traces registered with each individual detector of the SD using Recurrent Neural Networks. We derive the performances of the method by training the neural network on simulations, in which the muon and the electromagnetic components of the traces are known. We conclude this work showing the performance of this method on experimental data of the Pierre Auger Observatory. We find that our predictions agree with the parameterizations obtained by the AGASA collaboration to describe the lateral distributions of the electromagnetic and muonic components of extensive air showers.

hep-ex

Deep-Learning based Reconstruction of the Shower Maximum $X_{\mathrm{max}}$ using the Water-Cherenkov Detectors of the Pierre Auger Observatory

The atmospheric depth of the air shower maximum $X_{\mathrm{max}}$ is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of $X_{\mathrm{max}}$ are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect estimation of $X_{\mathrm{max}}$ from the characteristics of the shower particles registered with surface detector arrays. In this paper, we present a deep neural network (DNN) for the estimation of $X_{\mathrm{max}}$. The reconstruction relies on the signals induced by shower particles in the ground based water-Cherenkov detectors of the Pierre Auger Observatory. The network architecture features recurrent long short-term memory layers to process the temporal structure of signals and hexagonal convolutions to exploit the symmetry of the surface detector array. We evaluate the performance of the network using air showers simulated with three different hadronic interaction models. Thereafter, we account for long-term detector effects and calibrate the reconstructed $X_{\mathrm{max}}$ using fluorescence measurements. Finally, we show that the event-by-event resolution in the reconstruction of the shower maximum improves with increasing shower energy and reaches less than $25~\mathrm{g/cm^{2}}$ at energies above $2\times 10^{19}~\mathrm{eV}$.

astro-ph.IM

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

astro-ph.IM