SearcharxivSearch

arXiv subjects

X. Defay

Publications and source records attributed to X. Defay.

29 records · Page 2Linked to original sources

Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect

There is a common need in astroparticle experiments such as direct dark matter detection, 0ν\b{eta}\b{eta} (double beta decay without emission of neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light detectors with a very low energy threshold. By employing the Neganov-Luke Effect, the thermal signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures, can be amplified by drifting the photogenerated electrons and holes in an electric field. This technology is not used in current experiments, in particular because of a reduction of the signal amplitude with time which is due to trapping of the charges within the absorber. We present here the first results of a novel type of Neganov-Luke Effect detector with an electric field configuration designed to improve the charge collection within the semiconductor.

astro-ph.IM

The CRESST Dark Matter Search - Status and Perspectives

In the past years the spotlight of the search for dark matter particles widened to the low mass region, both from theoretical and experimental side. We discuss results from data obtained in 2013 with a single detector TUM40. This detector is equipped with a new upgraded holding scheme to efficiently veto backgrounds induced by surface alpha decays. This veto, the low threshold of 0.6keV and an unprecedented background level for CaWO$_4$ target crystals render TUM40 the detector with the best overall performance of CRESST-II phase 2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate light dark matter particles (<3GeV/c$^2$), previously not accessible for other direct detection experiments.

physics.ins-det

Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.

astro-ph.CO

Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments

The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.

astro-ph.CO

A detection system to measure muon-induced neutrons for direct Dark Matter searches

Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.

astro-ph.IM

Monitoring of the thermal neutron flux in the LSM underground laboratory

This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$π$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $Φ_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.

astro-ph.IM

First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.

astro-ph.CO

A new high-background-rejection dark matter Ge cryogenic detector

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $β$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.

astro-ph.IM

Proceedings of the 1st International Workshop "Radiopure Scintillators for EURECA" (RPScint'2008)

Workshop RPSCINT'2008 was organized in Kyiv (Ukraine) on 9th and 10th September 2008. The idea was to bring together physicists, chemists, crystal scintillator experts and manufacturers to discuss the requirements of low-count rate experiments, in particular the required radiopurity and scintillation properties; selection and screening of input materials; purification of materials; raw compound preparation; crystal growing, annealing and handling; test of crystals; search for and development of new scintillating materials. Some contributions to the RPSCINT 2008 workshop are presented in these proceedings.

nucl-ex

Identification of backgrounds in the EDELWEISS-I dark matter search experiment

This paper presents our interpretation and understanding of the different backgrounds in the EDELWEISS-I data sets. We analyze in detail the several populations observed, which include gammas, alphas, neutrons, thermal sensor events and surface events, and try to combine all data sets to provide a coherent picture of the nature and localisation of the background sources. In light of this interpretation, we draw conclusions regarding the background suppression scheme for the EDELWEISS-II phase.

astro-ph

Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.

astro-ph