Searcharxiv⌕ Search

arXiv subjects

X. Fléchard

Publications and source records attributed to X. Fléchard.

At least 19 recordsLinked to original sources

High-precision beam profile measurement with a microchannel-plate detector in the high magnetic field of the WISArD experiment

We present the development and characterization of a compact low-energy ion beam diagnostic for the WISArD (Weak Interaction Studies with $\mathrm{^{32}Ar}$ Decay) experiment at ISOLDE/CERN. The microchannel plate (MCP) detector, which is configured in a Z-stack and has a resistive position sensitive anode, was tested with both stable and radioactive beams. This work focuses on the image reconstruction method, which corrects the pincushion distortion inherent to the square-shaped resistive anode, and investigates the influence of the magnetic field on the detector performance. Our results demonstrate that the detector achieves beam profile measurements with sub-millimeter accuracy, while coping with the spatial and high-magnetic field (4 T) constraints of the experiment. These capabilities meet the precision requirements of the WISArD experiment for extracting the modified beta-neutrino angular correlation coefficient, ã$_{βν}$, with an uncertainty of 0.1%.

physics.ins-det↗

Backscattering Study of Electrons from 0.1 to 3.4 MeV

Benchmarking simulation codes for electron transport and scattering in matter is a crucial step for estimating uncertainties in many applications. However, experimental data for electron energies of a few MeV is scarce to make such comparisons. We report here the measurement and the quantitative analysis of backscattering probabilities of electrons in the energy range 0.1 to 3.4~MeV impinging on YAP:Ce scintillator. The setup consists of a $2\times 2π$ calorimeter which enables, in particular, the inclusion of large incidence angles. The results are used to benchmark various scattering models incorporated in Geant4, showing relative deviations smaller than 5% between experiment and simulations. They demonstrate the current rather high reliability of the simulations when employing appropriate electromagnetic Physics Lists.

nucl-ex↗

Optical studies of scintillation detectors for precision beta-energy measurements

This work presents optical calculations and simulations for scintillation detectors used in precision measurements of beta-particle energy spectra. Particular attention is given to Cherenkov photons and the impact of the light detection efficiency in the detector ensemble. We present an approach to estimate this light detection efficiency from the measured energy resolution of a detector. This is essential for the inclusion of scintillation photons in optical tracking Monte-Carlo simulations. A method to account for possible saturation and cross-talk of silicon photo-multipliers is also discussed. The impact of these effects is quantified in terms of systematic shifts in the extraction of the Fierz interference term from measurements of beta-energy spectra using scintillator detectors.

physics.ins-det↗

Search for a neutron dark decay in $^6$He

Neutron dark decays have been suggested as a solution to the discrepancy between bottle and beam experiments, providing a dark matter candidate that can be searched for in halo nuclei. The free neutron in the final state following the decay of $^6$He into $^4$He $+$ $n$ + $χ$ provides an exceptionally clean detection signature when combined with a high efficiency neutron detector. Using a high-intensity $^6$He$^+$ beam at GANIL, a search for a coincident neutron signal resulted in an upper limit on a dark decay branching ratio of Br$_χ\leq 4.0\times10^{-10}$ (95\% C.L.). Using the dark neutron decay model proposed originally by Fornal and Grinstein, we translate this into an upper bound on a dark neutron branching ratio of $\mathcal{O}(10^{-5})$, improving over global constraints by one to several orders of magnitude depending on $m_χ$.

nucl-ex↗

High precision measurement of the $^6$He half-life

The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$π$ geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, $T_{1/2} = (807.25 \pm 0.16_{\rm stat} \pm 0.11_{\rm sys}$)~ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the longstanding discrepancy previously observed between two sets of measurements.

nucl-ex↗

$β$-nuclear-recoil correlation from $^6$He decay in a laser trap

We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for left-handed neutrinos the limits are $0.007< C_T/C_A <0.111$~(90\%\ C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the micro-channel plate used for recoil ion detection.

nucl-ex↗

Investigation of the Carbon Monoxide Dication Lifetime Using (CO)$_2$ Dimer Fragmentation

The fragmentation of carbon monoxide dimers induced by collisions with low energy Ar$^{9+}$ ions is investigated using the COLTRIMS technique. The presence of a neighbor molecule in the dimer serves here as a diagnostic tool to probe the lifetimes of the $\rm CO^{2+}$ molecular dications resulting from the collision. The existence of metastable states with lifetimes ranging from 2~ps to 200~ns is clearly evidenced experimentally through a sequential 3-body fragmentation of the dimer, whereas fast dissociation channels are observed in a so-called concerted 3-body fragmentation process. The fast fragmentation process leads to a kinetic energy release distribution also observed in collisions with monomer CO targets. This is found in contradiction with the conclusions of a former study attributing this fast process to the perturbation induced by the neighbor molecular ion.

physics.atm-clus↗

Coulomb explosion imaging of carbon monoxide dimers

We report on experimental results obtained from collisions of slow highly charged Ar9+ ions with a carbon monoxide dimer (CO)2 target. A COLTRIMS setup and a Coulomb explosion imaging approach are used to reconstruct the structure of the CO dimers. The three dimensional structure is deduced from the 2-body and 3-body dissociation channels from which both the intermolecular bond length and the relative orientation of the two molecules are determined. For the 3-body channels, the experimental data are interpreted with the help of a classical model in which the trajectories of the three emitted fragments are numerically integrated. We measured the equilibrium intermolecular distance to be Re = 4.2 A. The orientation of both CO molecules with respect to the dimer axis is found to be quasi-isotropic due to the large vibrational temperature of the gas jet.

physics.atm-clus↗

Simultaneous Measurements of the Beta Neutrino Angular Correlation in $^{32}$Ar Pure Fermi and Pure Gamow-Teller Transitions using Beta-Proton Coincidences

We report first time measurements of the beta-neutrino angular correlation based on the kinetic energy shift of protons emitted in parallel or anti-parallel directions with respect to the positron in the beta decay of $^{32}$Ar. This proof of principle experiment provided simultaneous measurements for the superallowed 0$^+$~$\rightarrow$~0$^+$ transition followed by a 3356~keV proton emission and for a Gamow-Teller transition followed by a 2123~keV proton emission. The results, respectively ${\tilde a_{βν}}=1.01(3)_{(stat)}(2)_{(syst)}$ and ${\tilde a_{βν}}=-0.22(9)_{(stat)}(2)_{(syst)}$, are found in agreement with the Standard Model. A careful analysis of the data shows that future measurements can reach a precision level of 10$^{-3}$ for both pure Fermi and pure Gamow-Teller decay channels, providing new constraints on both scalar and tensor weak interactions.

nucl-ex↗

Geometry optimisation of a transparent axisymmetric ion trap for the MORA project

In the frame of the project MORA (Matter's Origin from the Radio Activity of trapped and oriented ions), a transparent axially symmetric radio-frequency ion trap (MORATrap) was designed in order to measure the triple correlation parameter $D$ in nuclear $β-$decay of laser-polarised ions. The trap design was inspired from the LPCTrap geometry, operated at GANIL from 2005 to 2013. In a real (non-ideal) Paul trap, the quadrupole electric potential is not perfect leading to instabilities in ion motion and therefore affecting the overall trapping efficiency. This paper presents a numerical method aiming to optimise the geometry of a trap. It is applied to MORATrap in order to improve the trapping efficiency and to enlarge the axial transparent solid angle compared to LPCTrap. In the whole optimisation process, numerical computation of electric potential and field was carried out using an electrostatic solver based on boundary element method (BEM). The optimisation consisted in minimising an objective function (fitness function) depending on higher order multipoles of the potential. Finally, systematic changes of trap dimensions and electrode displacements were applied to investigate geometrical effects on the potential quality.

physics.ins-det↗

The open LPC Paul trap for precision measurements in beta decay

The LPCTrap experiment uses an open Paul trap which was built to enable precision measurements in the beta decay of radioactive ions. The initial goal was the precise measurement of the beta-neutrino angular correlation coefficient in the decay of 6He. Its geometry results from a careful optimization of the harmonic potential created by cylindrical electrodes. It supersedes previously considered geometries that presented a smaller detection solid angle to the beta particle and the recoiling ion. We describe here the methods which were used for the potential optimization, and we present the measured performances in terms of trapping time, cloud size and temperature, and space charge related limits. The properties of the ion cloud at equilibrium are well reproduced by a simple numerical simulation using hard sphere collisions, which additionally gives insights on the trapping loss mechanism. The interpretation for the observed trapping liftetimes is further corroborated by a model recently developed for ion clouds in Paul traps. The open trap shall serve other projects. It is currently used for commissioning purpose in the TRAPSENSOR experiment and is also considered in tests of the Standard Model involving the beta decay of polarized $^{23}$Mg and $^{39}$Ca ion in the frame of the MORA experiment. The latter tests require in-trap polarization of the ions and further optimization of the trapping and detection setup. Based on the results of the simulations and of their interpretations given by the model, different improvements of the trapping setup are discussed.

physics.ins-det↗

The MORA project

The MORA (Matter's Origin from the RadioActivity of trapped and oriented ions) project aims at measuring with unprecedented precision the D correlation in the nuclear beta decay of trapped and oriented ions. The D correlation offers the possibility to search for new CP-violating interactions, complementary to searches done at the LHC and with Electric Dipole Moments. Technically, MORA uses an innovative in-trap orientation method which combines the high trapping efficiency of a transparent Paul trap with laser orientation techniques. The trapping, detection, and laser setups are under development, for first tests at the Accelerator laboratory, JYFL, in the coming years.

physics.ins-det↗

A Coulomb Over-the-Barrier Monte Carlo Simulation to probe Ion-Dimer Collision Dynamics

We present a combined theoretical and experimental study of primary and post-collision mechanisms involved when colliding low energy multiply charged ions with van der Waals dimers. The collision dynamics is investigated using a classical calculation based on the Coulombic Over-the- Barrier Model adapted to rare-gas dimer targets. Despite its simplicity, the model predictions are found in very good agreement with experimental results obtained using COLd Target Recoil Ion Momentum Spectroscopy (COLTRIMS), both for the relative yields of the different relaxation processes and for the associated transverse momentum exchange distributions between the projectile and the target. This agreement shows to which extent van der Waals dimers can be assimilated to independent atoms.

physics.atm-clus↗

Electron shakeoff following the \b{eta}+ decay of 19Ne+ and 35Ar+ trapped ions

The electron shakeoff of 19F and 35Cl atoms resulting from the \b{eta}+ decay of 19Ne+ and 35Ar+ ions has been investigated using a Paul trap coupled to a time of flight recoil-ion spectrometer. The charge-state distributions of the recoiling daughter nuclei were compared to theoretical calculations based on the sudden approximation and accounting for subsequent Auger processes. The excellent agreement obtained for 35Cl is not reproduced in 19F. The shortcoming is attributed to the inaccuracy of the independent particle model employed to calculate the primary shakeoff probabilities in systems with rather low atomic numbers. This calls for more elaborate calculations, including explicitly the electron-electron correlations.

nucl-ex↗

High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition

The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569\pm0.0019_{(stat)}\pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {\it et al.}, Phys. Rev. Lett. {\bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.

nucl-ex↗

Atomic site sensitive processes in low energy ion-dimer collisions

Electron capture processes for low energy Ar9+ ions colliding on Ar2 dimer targets are investigated, focusing attention on charge sharing as a function of molecule orientation and impact parameter. A preference in charge-asymmetric dissociation channels is observed, with a strong correlation between the projectile scattering angle and the molecular ion orientation. The measurements provide here clear evidences that projectiles distinguish each atom in the target and, that electron capture from near-site atom is favored. Monte Carlo calculations based on the classical over-the-barrier model, with dimer targets represented as two independent atoms, are compared to the data. They give a new insight into the dynamics of the collision by providing, for the di erent electron capture channels, the two-dimensional probability maps p(~b), where ~b is the impact parameter vector in the molecular frame.

nucl-ex↗

Electron shakeoff following the ?+ decay of trapped 35Ar+ ions

The electron shakeoff of $^{35}$Cl atoms resulting from the $β$$^+$ decay of $^{35}$Ar$^+$ ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The charge-state distribution of the recoiling daughter nuclei is compared to theoretical calculations accounting for shakeoff and Auger processes. The calculations are in excellent agreement with the experimental results and enable to identify the ionization reaction routes leading to the formation of all charge states.

nucl-ex↗

Precision measurements in nuclear β-decay with LPCTrap

The experimental achievements and the current program with the LPCTrap device installed at the LIRAT beam line of the SPIRAL1-GANIL facility are presented. The device is dedicated to the study of the weak interaction at low energy by means of precise measurements of the β-ν angular correlation parameter. Technical aspects as well as the main results are reviewed. The future program with new available beams is briefly discussed.

nucl-ex↗