SearcharxivSearch

arXiv subjects

X. G. Cao

Publications and source records attributed to X. G. Cao.

At least 19 recordsLinked to original sources

On the High Excitation 7$α$ De-exciting States in $^{28}$Si$^*$

A direct comparison and analysis of published spectra for the 7$α$ disassembly of $^{28}$Si projectiles excited in collisions with $^{12}$C at 35 MeV/u reveals significant agreement in the derived excitation energies of high excitation energy resonances observed in two different experiments, in contrast to some earlier conclusions reported in the literature. Many of the observed resonances have excitation energies consistent with those arrived at in recent theoretical investigations explicitly predicting the excitation energies and spins of toroidal nuclei. An AI-assisted application of well-established statistical filtering techniques reveals identical structures in all spectra investigated. Some additional peaks are observed. The possibility that they correspond to other favored geometries is discussed.

nucl-ex

New direct limit on neutrinoless double beta decay half-life of $^{128}$Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0$νββ$) decay. Its main goal is to investigate this decay in $^{130}$Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. In this work, we present our first results on the search for \nbb decay of $^{128}$Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the $^{128}$Te \nbb decay half-life of T$_{1/2} > 3.6 \times 10^{24}$ yr (90\% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.

nucl-ex

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

physics.ins-det

Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

nucl-ex

Effects of neutron-skin thickness on direct hard photon emission from reactions induced by the neutron-rich projectile $^{50}$Ca

Direct hard photon emissions from incoherent proton-neutron bremsstrahlung in collisions of the neutron-rich projectile $^{50}$Ca with $^{12}$C and $^{40}$Ca targets are simulated in the framework of the isospin-dependent quantum molecular dynamics (IQMD) model. By adjusting the diffuseness parameter of neutron density in the droplet model to obtain different neutron skin thicknesses for $^{50}$Ca, the effects of neutron skin thickness on direct hard photon emission are investigated via several probes. The results show that more direct hard photons are produced with increasing neutron skin thickness in peripheral collisions. Meanwhile, we find that the multiplicity yield ratio $R_{cp}(σ_γ)$ between central collisions and peripheral collisions as well as the rapidity dependence of multiplicity for direct hard photons are sensitive to neutron skin thickness. The results indicate that direct hard photon emission can be taken as an experimental observable to extract information on neutron skin thickness.

nucl-th

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

nucl-ex

Neutron capture measurement and resonance parameter analysis of natSm

Multiple isotopes of samarium element are the isotopes produced by the s process, and 154Sm is produced by the r process. In addition, 144Sm is p nuclei in nuclear astrophysics. The measurement of these can help us to better understand the results of relevant photonuclear reaction experiments. On the other hand, 149Sm is a 235U fission product with a 1% yield, its cross sections are important to reactor neutronics. In this work, the neutron capture yield of the natural samarium target was measured at the back-streaming white neutron beamline (Back-n) of the China Spallation Neutron Source (CSNS), and the resonance parameters were analyzed by SAMMY code. The resonance peaks and the neutron separation energies contributed by the different isotopes are considered individually. The results of the capture yield found signs of the possibility of two resonance peaks at 8 eV, which awaits further experimental examination. Cross-section was calculated according to resonance parameters and was compared with other experimental results and evaluation databases of ENDF/B-VIII.0 and CENDL-3.2. A clear difference between ENDF/B VIII.0 and CENDL-3.2 database appears at 23.2 eV, the experimental result at this energy is smaller than data of ENDF/B VIII.0 database but CENDL-3.2 database. Most of the controversial experimental results invariably come from the samarium 149 isotope.

nucl-ex

p-process chaser detector in $n$-$γ$ coincidences

We propose two types of neutron-$γ_1$-$γ_2$ triple coincidence detectors (not constructed) to chase gamma transitions to produce p-nuclei following the neutron emission in the $(γ, n)$ reaction. Neutrons are detected with 24 $^3$He counters embedded in a polyethylene moderator in Type I detector and with 6 liquid scintillation detectors in Type II detector, respectively. $γ$ rays are detected with two high-purity germanium detectors and four LaBr$_3$(Ce) detectors. The detector which is referred to as p-process chaser detector is used to search for mediating states in $^{180}$Ta through which the isomeric and ground states in $^{180}$Ta are thermalized in the p-process. A search is made for both resonant states and unresolved states in high nuclear-level-density domain.

physics.ins-det

CUORE Opens the Door to Tonne-scale Cryogenics Experiments

The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require ever greater exposures, which has driven them to ever larger cryogenic detectors, with the CUORE experiment being the first to reach a tonne-scale, mK-cooled, experimental mass. CUORE, designed to search for neutrinoless double beta decay, has been operational since 2017 at a temperature of about 10 mK. This result has been attained by the use of an unprecedentedly large cryogenic infrastructure called the CUORE cryostat: conceived, designed and commissioned for this purpose. In this article the main characteristics and features of the cryogenic facility developed for the CUORE experiment are highlighted. A brief introduction of the evolution of the field and of the past cryogenic facilities are given. The motivation behind the design and development of the CUORE cryogenic facility is detailed as are the steps taken toward realization, commissioning, and operation of the CUORE cryostat. The major challenges overcome by the collaboration and the solutions implemented throughout the building of the cryogenic facility will be discussed along with the potential improvements for future facilities. The success of CUORE has opened the door to a new generation of large-scale cryogenic facilities in numerous fields of science. Broader implications of the incredible feat achieved by the CUORE collaboration on the future cryogenic facilities in various fields ranging from neutrino and dark matter experiments to quantum computing will be examined.

physics.ins-det

Search for Double-Beta Decay of $\mathrm{^{130}Te}$ to the $0^+$ States of $\mathrm{^{130}Xe}$ with CUORE

The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ($0νββ$) in the isotope $\mathrm{^{130}Te}$. In this work we present the latest results on two searches for the double beta decay (DBD) of $\mathrm{^{130}Te}$ to the first $0^{+}_2$ excited state of $\mathrm{^{130}Xe}$: the $0νββ$ decay and the Standard Model-allowed two-neutrinos double beta decay ($2νββ$). Both searches are based on a 372.5 kg$\times$yr TeO$_2$ exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90\% Credible Interval (C.I.) of the given searches were estimated as $\mathrm{S^{0ν}_{1/2} = 5.6 \times 10^{24} \: \mathrm{yr}}$ for the ${0νββ}$ decay and $\mathrm{S^{2ν}_{1/2} = 2.1 \times 10^{24} \: \mathrm{yr}}$ for the ${2νββ}$ decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $90\%$ C.I. on the decay half lives is obtained as: $\mathrm{(T_{1/2})^{0ν}_{0^+_2} > 5.9 \times 10^{24} \: \mathrm{yr}}$ for the $0νββ$ mode and $\mathrm{(T_{1/2})^{2ν}_{0^+_2} > 1.3 \times 10^{24} \: \mathrm{yr}}$ for the $2νββ$ mode. These represent the most stringent limits on the DBD of $^{130}$Te to excited states and improve by a factor $\sim5$ the previous results on this process.

nucl-ex

Measurement of the 2$νββ$ Decay Half-life of $^{130}$Te with CUORE

We measured two-neutrino double beta decay of $^{130}$Te using an exposure of 300.7 kg$\cdot$yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: $T^{2ν}_{1/2} = 7.71^{+0.08}_{-0.06}\mathrm{(stat.)}^{+0.12}_{-0.15}\mathrm{(syst.)}\times10^{20}$ yr. This measurement is the most precise determination of the $^{130}$Te 2$νββ$ decay half-life to date.

nucl-ex

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.

physics.ins-det

Azimuthal anisotropy and multiplicities of hard photons and free nucleons in intermediate-energy heavy-ion collisions

Anisotropic flow can offer significant information of evolution dynamics in heavy-ion collisions. A systematic study of the directed flow $v_1$ and elliptic flow $v_2$ of hard photons and free nucleons is performed for $^{40}$Ca+$^{40}$Ca collisions in a framework of isospin dependent quantum molecular dynamics (IQMD) model. The study firstly reveals that thermal photons emitted in intermediate-energy heavy-ion collisions have the behaviors of directed and elliptic flows. The interesting phenomena of incident energy dependence of $v_1$ and $v_2$ for thermal photons in central collisions also confirmed that it can be regarded as a good probe of evolution dynamics. Moreover, the multiplicities of hard photons and free nucleons and their correlation are also investigated. We find that direct photon emission is positively related to free nucleons emission, however, there exists an anti-correlation for thermal photons with free nucleons.

nucl-th

Direct photon emission and influence of dynamical wave packets in an extended quantum molecular dynamics model

Direct photon produced from first proton-neutron ($p$-$n$) collision during the early stage of heavy ion reaction is a sensitive probe to reflect energy and momentum distribution of nucleons. In this work, we embedded the hard photon production channel in an extended quantum molecular dynamics (EQMD) model, and took the direct photon as a possible probe to improve namely the Fermi motion in the EQMD model. A possible scheme is offered to handle the dynamical wave packet width within incoherent bremsstrahlung process. Direct photons calculated by our modified EQMD were compared with data of $^{14}$N + $^{12}$C at beam energies $E/A$ = 20, 30 and 40 MeV, and it is found that the yield, inverse slope and angular distribution of direct photons could be reasonably reproduced. In addition, asymmetric reaction systems of $^{4}$He + C and $^{4}$He + Zn at $E/A$ = 53 MeV are also simulated in this work. It is found that the symmetric angular distribution in the nucleon-nucleon ($N$-$N$) center-of-mass (c.m.) frame and the velocity of $ the γ$-emission source can be reasonably obtained from our method although there is some quantitative differences.

nucl-th

Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE

We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

nucl-ex

Nuclear probes of an out-of-equilibrium plasma at the highest compression

We report the highest compression reached in laboratory plasmas using eight laser beams, E$_{laser}$$\approx$12 kJ, $τ_{laser}$=2 ns in third harmonic on a CD$_2$ target at the ShenGuang-II Upgrade (SGII-Up) facility in Shanghai, China. We estimate the deuterium density $ρ_D$= 2.0 $\pm$ 0.9 kg/cm$^{3}$, and the average kinetic energy of the plasma ions less than 1 keV. The highest reached areal density $Λρ_{D}$=4.8 $\pm$ 1.5 g/cm$^{2}$ was obtained from the measured ratio of the sequential ternary fusion reactions (dd$\rightarrow$t+p and t+d$\rightarrow$$α$+n) and the two body reaction fusions (dd$\rightarrow$$^3$He+n). At such high densities, sequential ternary and also quaternary nuclear reactions become important as well (i.e. n(14.1 MeV) + $^{12}$C $\rightarrow$ n'+$^{12}$C* etc.) resulting in a shift of the neutron (and proton) kinetic energies from their birth values. The Down Scatter Ratio (DSR-quaternary nuclear reactions) method, i.e. the ratio of the 10-12MeV neutrons divided by the total number of 14.1MeV neutrons produced, confirms the high densities reported above. The estimated lifetime of the highly compressed plasma is 52 $\pm$ 9 ps, much smaller than the lasers pulse duration.

physics.plasm-ph

Results of CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) at the Laboratori Nazionali del Gran Sasso, Italy, is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently in data taking, searching for the neutrinoless double beta decay of 130 Te. CUORE is operational since the spring of 2017. The initial science run already allowed to provide the most stringent limit on the neutrinoless double beta decay half-life of 130Te, and to perform the most precise measurement of the two-neutrino double beta decay half-life. Up to date, we have more than doubled the collected exposure. In this talk, we presenteded the most recent results and discuss the present status of the CUORE experiment.

nucl-ex

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.

nucl-ex