SearcharxivSearch

arXiv subjects

X. L. Sun

Publications and source records attributed to X. L. Sun.

15 recordsLinked to original sources

Reactor neutrino physics potentials of cryogenic pure-CsI crystal

This paper presents a world-leading scintillation light yield among inorganic crystals measured from a 0.5~kg pure-CsI detector operated at 77 Kelvin. Scintillation photons were detected by two 2-inch Hamamatsu SiPM arrays equipped with cryogenic front-end electronics. Benefiting the light yield enhancement of pure-CsI at low temperatures and the high photon detection efficiency of SiPM, a light yield of 30.1 photoelectrons per keV energy deposit was obtained for X-rays and $γ$-rays with energies from 5.9~keV to 59.6~keV. Instrumental and physical effects in the light yield measurement are carefully analyzed. This is the first stable cryogenic operation of kg-scale pure-CsI crystal readout by SiPM arrays at liquid nitrogen temperatures for several days. The world-leading light yield opens a door for the usage of pure-CsI crystal in several fields, particularly in detecting the coherent elastic neutrino-nucleus scattering of reactor neutrinos. The potential of using pure-CsI crystals in neutrino physics is discussed in the paper.

physics.ins-det

The First GECAM Observation Results on Terrestrial Gamma-ray Flashes and Terrestrial Electron Beams

Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is a space-borne instrument dedicated to monitoring high-energy transients, including Terrestrial Gamma-ray Flashes (TGFs) and Terrestrial Electron Beams (TEBs). We implemented a TGF/TEB search algorithm for GECAM, with which 147 bright TGFs, 2 typical TEBs and 2 special TEB-like events are identified during an effective observation time of $\sim$9 months. We show that, with gamma-ray and charged particle detectors, GECAM can effectively identify and distinguish TGFs and TEBs, and measure their temporal and spectral properties in detail. A very high TGF-lightning association rate of $\sim$80\% is obtained between GECAM and GLD360 in east Asia region.

astro-ph.HE

The Design and Performance of Charged Particle Detector onboard the GECAM Mission

The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.

astro-ph.IM

Quality assurance test and Failure Analysis of SiPM Arrays of GECAM Satellites

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) satellite consists of two small satellites. Each GECAM payload contains 25 gamma ray detectors (GRD) and 8 charged particle detectors (CPD). GRD is the main detector which can detect gamma-rays and particles and localize the Gamma-Ray Bursts (GRB),while CPD is used to help GRD to discriminate gamma-ray bursts and charged particle bursts. The GRD makes use of lanthanum bromide (LaBr3) crystal readout by SiPM. As the all available SiPM devices belong to commercial grade, quality assurance tests need to be performed in accordance with the aerospace specifications. In this paper, we present the results of quality assurance tests, especially a detailed mechanism analysis of failed devices during the development of GECAM. This paper also summarizes the application experience of commercial-grade SiPM devices in aerospace payloads, and provides suggestions for forthcoming SiPM space applications.

physics.ins-det

Dedicated SiPM array for GRD of GECAM

The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.

hep-ex

Inflight performance of the GECAM Gamma-ray and Charge particle Detectors

The GECAM mission consists of two identical microsatellites (GECAM-A and GECAM-B). Each satellite is equipped with 25 gamma-ray detectors (GRD) and 8 charged particle detectors (CPD). The main scientific objective of the GECAM mission is to detect gamma-ray bursts (GRBs) associated with the gravitational wave events produced by the merging of binary compact stars. After the launch on Dec. 10, 2020 , we carried out a series of on orbit tests. This paper introduces the test results of the GECAM-B satellite. According to the in-flight performance, the energy band for gamma-ray detection of GECAM-B is from about 7 keV to 3.5 MeV. GECAM-B can achieve prompt localization of GRBs. For the first time, GECAM-B realized a quasi-real-time transmission of trigger information using Beidou-3 RDSS. Keywords GECAM, gamma-ray burst, gravitational wave, GRD, CPD

physics.ins-det

The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload

The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.

astro-ph.IM

Ground-based calibration and characterization of GRD of GECAM: 8-160 keV

As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.

astro-ph.IM

The design and performance of GRD onboard the GECAM satellite

Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.

astro-ph.IM

GECAM detection of a bright type-I X-ray burst from 4U 0614+09: confirmation its spin frequency at 413 Hz

One month after launching Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM), a bright thermonuclear X-ray burst from 4U~0614+09, was observed on January 24, 2021. We report the time-resolved spectroscopy of the burst and a burst oscillation detection at 413 Hz with a fractional amplitude 3.4\% (rms). This coincides with the burst oscillation previously discovered with \textit{Swift}/BAT \citep{Strohmayer2008}, and therefore confirms the spin frequency of this source. This burst is the brightest one in the normal bursts (except the superburst) ever detected from 4U~0614+09, which leads to an upper limit of distance estimation as 3.1 kpc. The folded light curve during the burst oscillation shows a multi-peak structure, which is the first case observed during a single burst oscillation in nonpulsating sources. The multi-peak profile could be due to additional harmonics of the burst oscillation, which is corresponding to several brighter/fainter spots at the stellar surface.

astro-ph.HE

Characterization of VUV4 SiPM for Liquid Argon Detector

Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370-6050CN SiPM, including the cross talk and after pulse probabilities at liquid argon temperature and the temperature dependence of break down voltage, dark counting rate and relative quantum efficiency were presented.

physics.ins-det

A low-energy sensitive compact gamma-ray detector based on LaBr3 and SiPM for GECAM

The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) project is the planned Chinese space telescope for detecting the X and gamma-ray counterpart. It consists of two micro-satellites in low earth orbit with the advantages of instantaneous full-sky coverage, low energy threshold down to 6 keV and can be achieved within a short period and small budget. Due to the limitation of size, weight and power consumption of micro-satellites, silicon photomultipliers (SiPMs) are used to replace the photomultiplier tubes (PMTs) to assemble a novel gamma-ray detector. A prototype of a SiPM array with LaBr3 crystal is built and tested, and it shows a high detection efficiency (70% at 5.9 keV) and an acceptable uniformity. The low-energy X-ray of 5.9 keV can be detected by a simply readout circuit, and the energy resolution is 6.5% (FWHM) at 662 keV. The design and performance of the detector are discussed in detail in this paper.

astro-ph.IM

Measurement of proton quenching in a LAB based liquid scintillator

Linear alkylbenzene has been recently used as the solvent of liquid scintillator by several neutrino experiments. The energy quenching effect of a linear alkylbenzene based liquid scintillator is studied in this paper with a 14 MeV D-T compact neutron generator, to improve the energy non-linearity modelling of this kind of detectors. The recoiled proton in the liquid scintillator has a kinetic energy ranging from 0.5 MeV to 13 MeV. The data is used to extract the parameters of the Birk's law, an empirical model to describe the energy quenching effect of the liquid scintillator.

physics.ins-det

Study of Silicon Photomultiplier Performance in External Electric Fields

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The SiPM devices used in this study show stable gain, photon detection efficiency, and rates of correlated pulses, when exposed to external fields, within the estimated uncertainties. No observable physical damage to the bulk or surface of the devices was caused by the exposure.

physics.ins-det

Suppression of Dick Effect in the Ramsey-CPT atomic clock by Interleaving Lock

For most passive atomic clocks, the Dick effect is one of the main limits to reach its frequency stability limitation due to quantum projection noise. In this paper, we demonstrate that the minimization of the Dick effect for the Ramsey-CPT atomic clock can be accomplished by interleaving lock. By optimizing the duty circle of laser pulses, averaging time during detection and optical intensity of laser beam, the Dick effect induced Allan deviation can be reduced to the level of 10^-14.

physics.ins-det