SearcharxivSearch

arXiv subjects

Xavier Vacheret

Publications and source records attributed to Xavier Vacheret.

4 recordsLinked to original sources

A new method of probing mechanical losses of coatings at cryogenic temperatures

A new method of probing mechanical losses and comparing the corresponding deposition processes of metallic and dielectric coatings in 1-100 MHz frequency range and cryogenic temperatures is presented. The method is based on the use of extremely high-quality quartz acoustic cavities whose internal losses are orders of magnitude lower than any available coatings nowadays. The approach is demonstrated for Chromium, Chromium/Gold and a multilayer tantala/silica coatings. The ${\rm Ta}_2{\rm O}_5/{\rm Si}{\rm O}_2$ coating has been found to exhibit a loss angle lower than $1.6\times10^{-5}$ near 30 {\rm MHz} at 4 {\rm K}. The results are compared to the previous measurements.

physics.ins-det

About Quartz Crystal Resonator Noise: Recent Study

The first step, before investigating physical origins of noise in resonators, is to investigate correlations between external measurement parameters and the resonator noise. Tests and measurements are mainly performed on an advanced phase noise measurement system, recently set up. The resonator noise is examined as a function of the sensitivity to the drive level, the temperature operating point and the tuning capacitor.

physics.ins-det

Development of a 5 MHz frequency difference pre-multiplier for a short term frequency stability bench of the oscillators

This paper reports the realization of a 5 MHz frequency difference x10 pre-multiplier, developed in the laboratory to replace an obsolete one. The principle we chose is to synthesize a 45 MHz and a 50 MHz from a reference signal and from the signal to be measured, and to subtract one to the other to generate a 5 MHz, whose precision on the measurement is increased by a factor 10. Obtained Allan variance y() at 1 s is 5.10-14 and output spectral density of phase noise floor is about -160 dBc/Hz at 5 MHz.

physics.ins-det

Advanced bridge instrument for the measurement of the phase noise and of the short-term frequency stability of ultra-stable quartz resonators

High-stability quartz oscillators are needed in a number of space applications. A short-term stability of parts in 10^{-14} [Allan deviation σy(τ) ] is sometimes required, for integration time τof approximately 1-10 s. The Centre National d'Etudes Spatiales (CNES) and the FEMTO-ST Institute (formerly LPMO and LCEP), have been collaborating for many years in this domain, aiming at measuring and at understanding the oscillator noise. The highest stability has been observed on 5 MHz and 10 MHz bulk acoustic-wave resonators. Yet this stability is still not sufficient, or the the manufacturing method is not reproducible. Recently, the analysis of a few premium-stability oscillators has demonstrated that the oscillator frequency instability is due to the fluctuation of the resonator natural frequency, rather than to the noise of the sustaining amplifier via the Leeson effect. It is therefore natural to give attention to the measurement of the resonator fluctuations.

physics.ins-det