SearcharxivSearch

arXiv subjects

Xiankang Dou

Publications and source records attributed to Xiankang Dou.

12 recordsLinked to original sources

A high-resolution microresonator-frequency-comb spectrometer

Spectral analysis is one of the most powerful technologies for studying and understanding matter. As the devices for spectral analysis, spectrometers are widely used in material detection, isotope analysis, trace gas detection, and the study of atomic and molecular hyperfine structures. While high resolution, wide bandwidth and fast speed are essential factors, they are always trade-offs for conventional spectrometers. Here, we present a soliton-microcomb-based spectrometer that overcomes these challenges by integrating dissipative Kerr solitons (DKSs) with double-sideband modulation and parallelized detection. Leveraging a high-quality silicon nitride microresonator, we generate a broadband, fully stabilized soliton microcomb and employ radio-frequency-modulated double sidebands to scan the optical spectrum with the resolution constrained only by the comb-line linewidth. By projecting the comb lines onto a two-dimensional charge-coupled device (CCD) via a virtually imaged phased array (VIPA)-grating system, we enable parallel processing of all spectral components, circumventing sequential scanning delays. The resulting spectrometer achieves 200-kHz resolution across a 4-THz bandwidth with minutes-level processing time while maintaining robustness against environmental fluctuations. Being promising for miniaturization, this work bridges the gap between laboratory-grade performance and field-deployable practicality, unlocking new possibilities for spectroscopy in astronomy, metrology, and integrated photonics.

physics.optics

Differential absorption ozone Lidar with 4H-SiC single-photon detectors

Differential absorption Lidar (DIAL) in the ultraviolet (UV) region is an effective approach for monitoring tropospheric ozone. 4H-SiC single-photon detectors (SPDs) are emergent devices for UV single-photon detection. Here, we demonstrate a 4H-SiC SPD-based ozone DIAL. We design and fabricate the 4H-SiC single-photon avalanche diode with a beveled mesa structure and optimized layer thickness. An active quenching circuit with a quenching time of 1.03 ns is developed to significantly mitigate the afterpulsing effect while enhancing the maximum count rate. After characterization, the SPD exhibits excellent performance with a photon detection efficiency of 16.6% at 266 nm, a dark count rate of 138 kcps, a maximum count rate of 13 Mcps, and an afterpulse probability of 2.7% at room temperature. Then, we apply two 4H-SiC SPDs in an ozone DIAL. The measured ozone concentrations at altitudes of 1-3.5 km agree well with the results of a commercial ozone DIAL. Our work provides an alternative solution for general UV Lidar applications.

physics.optics

LWFNet: Coherent Doppler Wind Lidar-Based Network for Wind Field Retrieval

Accurate detection of wind fields within the troposphere is essential for atmospheric dynamics research and plays a crucial role in extreme weather forecasting. Coherent Doppler wind lidar (CDWL) is widely regarded as the most suitable technique for high spatial and temporal resolution wind field detection. However, since coherent detection relies heavily on the concentration of aerosol particles, which cause Mie scattering, the received backscattering lidar signal exhibits significantly low intensity at high altitudes. As a result, conventional methods, such as spectral centroid estimation, often fail to produce credible and accurate wind retrieval results in these regions. To address this issue, we propose LWFNet, the first Lidar-based Wind Field (WF) retrieval neural Network, built upon Transformer and the Kolmogorov-Arnold network. Our model is trained solely on targets derived from the traditional wind retrieval algorithm and utilizes radiosonde measurements as the ground truth for test results evaluation. Experimental results demonstrate that LWFNet not only extends the maximum wind field detection range but also produces more accurate results, exhibiting a level of precision that surpasses the labeled targets. This phenomenon, which we refer to as super-accuracy, is explored by investigating the potential underlying factors that contribute to this intriguing occurrence. In addition, we compare the performance of LWFNet with other state-of-the-art (SOTA) models, highlighting its superior effectiveness and capability in high-resolution wind retrieval. LWFNet demonstrates remarkable performance in lidar-based wind field retrieval, setting a benchmark for future research and advancing the development of deep learning models in this domain.

physics.ao-ph

A photon-level broadband dual-comb interferometer for turbulent open-air trace gases detection application

Open-path dual-comb spectroscopy (DCS) significantly enhances our understanding of regional trace gases. However, due to technical challenges, cost considerations, and eye-safety regulations, its sensing range and flexibility remain limited. The photon-counting DCS demonstrated recently heralds potential innovations over open-path DCS. Nevertheless, a major challenge in open-air applications of this approach lies in accurately extracting information from the arrival time of photons that have traversed the turbulent atmosphere. Here, we demonstrate a photon-level dual-comb interferometer for field deployment in open-air environments, uniquely designed to counteract the impact of optical path-length variations caused by atmospheric turbulence and fiber-length wandering. Under variable optical path-length conditions, 20nm broadband absorption spectrum of H13C14N is acquired, with the power per comb line detected as low as 4 attowatt . Furthermore, this photon-level DCS achieves comb-line resolution with a quantum-noise-limited signal-to-noise (SNR). This paves the way for novel open-path DCS applications, including non-cooperative target sensing and sensing over a hundred-kilometers range, all within a portable, fieldable, eye-safety and low power consumption system.

physics.optics

Compact and lightweight 1.5 μm lidar with a multi-mode fiber coupling free-running InGaAs/InP single-photon detector

We present a compact and lightweight 1.5 μm lidar using a free-running single-photon detector (SPD) based on a multi-mode fiber (MMF) coupling InGaAs/InP negative feedback avalanche diode. The ultimate light detection sensitivity of SPD highly reduces the power requirement of laser, whilst the enhanced collection efficiency due to MMF coupling significantly reduces the volume and weight of telescopes. We develop a specific algorithm for the corrections of errors caused by the SPD and erbium-doped fiber amplifier to extract accurate backscattering signals. We also perform a comparison between single-mode fiber (SMF) coupling and MMF coupling in the lidar receiver, and the results show that the collection efficiency with MMF coupling is five times higher than SMF coupling. In order to validate the functionality, we use the lidar system for the application of cloud detection. The lidar system exhibits the ability to detect both the cloud base height and the thickness of multi-layer clouds to an altitude of 12 km with a temporal resolution of 1 s and a spatial resolution of 15 m. Due to the advantages of compactness and lightweight, our lidar system can be installed on unmanned aerial vehicles for wide applications in practice.

physics.app-ph

Adaptive inversion algorithm for 1.5 um visibility lidar incorporating in situ Angstrom wavelength exponent

As one of the most popular applications of lidar systems, the atmospheric visibility is defined to be inversely proportional to the atmospheric extinction coefficient at 0.55 um. Since the laser at 1.5 um shows the highest maximum permissible exposure in the wavelength ranging from 0.3 um to 10 um, the eye-safe 1.5 um lidar can be deployed in urban areas. In such a case, the measured extinction coefficient at 1.5 um should be converted to that at 0.55 um for visibility retrieval. Although several models have been established since 1962, the accurate wavelength conversion remains a challenge. An adaptive inversion algorithm for 1.5 um visibility lidar is proposed and demonstrated by using the in situ Angstrom wavelength exponent, which is derived from either a sun photometer or an aerosol spectrometer. The impact of the particle size distribution of atmospheric aerosols and the Rayleigh backscattering of atmospheric molecules are taken into account. In comparison, the Angstrom wavelength exponent derived from the sun photometer is 7.7% higher than that derived from the aerosol spectrometer. Then, using 1.5 um visibility lidar, the visibility with a temporal resolution of 5 min is detected over 48 hours in Hefei (31.83 N, 117.25 E). The average visibility error between the new method and a visibility sensor (Vaisala, PWD52) is 5.2% with the R-square value of 0.96, while the relative error between another reference visibility lidar at 532 nm and the visibility sensor is 6.7% with the R-square value of 0.91. All results agree with each other well, demonstrating the accuracy and stability of the algorithm.

physics.ao-ph

Fully integrated free-running InGaAs/InP single-photon detector for accurate lidar applications

We present a fully integrated InGaAs/InP negative feedback avalanche diode (NFAD) based free-running single-photon detector (SPD) designed for accurate lidar applications. A free-piston Stirling cooler is used to cool down the NFAD with a large temperature range, and an active hold-off circuit implemented in a field programmable gate array is applied to further suppress the afterpulsing contribution. The key parameters of the free-running SPD including photon detection efficiency (PDE), dark count rate (DCR), afterpulse probability, and maximum count rate (MCR) are dedicatedly optimized for lidar application in practice. We then perform a field experiment using a Mie lidar system with 20 kHz pulse repetition frequency to compare the performance between the free-running InGaAs/InP SPD and a commercial superconducting nanowire single-photon detector (SNSPD). Our detector exhibits good performance with 1.6 Mcps MCR (0.6 μs hold-off time), 10% PDE, 950 cps DCR, and 18% afterpulse probability over 50 μs period. Such performance is worse than the SNSPD with 60% PDE and 300 cps DCR. However, after performing a specific algorithm that we have developed for afterpulse and count rate corrections, the lidar system performance in terms of range-corrected signal (Pr2) distribution using our SPD agrees very well with the result using the SNSPD, with only a relative error of ~2%. Due to the advantages of low-cost and small size of InGaAs/InP NFADs, such detector provides a practical solution for accurate lidar applications.

quant-ph

Brillouin optical time domain reflectometry for fast detection of dynamic strain incorporating double-edge technique

For the first time, a direct detection BOTDR is demonstrated for distributed dynamic strain sensing incorporating double-edge technique, time-division multiplexing technique and upconversion technique. The double edges are realized by using the transmission curve and reflection curve of an all-fiber Fabry-Perot interferometer (FPI). Benefiting from the low loss of the fiber at, the time-division multiplexing technique is performed to realize the double-edge technique by using only a single-channel FPI and only one piece of a detector. In order to detect the weak spontaneous Brillouin backscattering signal efficiently, a fiber-coupled upconversion detector is adopted to upconvert the backscattering signal at 1548.1 nm to 863 nm, which is detected by a Si-APD finally. In the experiment, dynamic strain disturbance up to 1.9mε over 1.5 km of polarization maintaining fiber is detected at a sampling rate of 30 Hz. An accuracy of 30με and spatial resolution of 0.6 m is realized.

physics.ins-det

All-fiber upconversion high spectral resolution wind lidar using a Fabry-Perot interferometer

An all-fiber, micro-pulse and eye-safe high spectral resolution wind lidar (HSRWL) at 1550nm is proposed and demonstrated by using a pair of upconversion single-photon detectors and a fiber Fabry-Perot scanning interferometer (FFP-SI). In order to improve the optical detection efficiency, both the transmission spectrum and the reflection spectrum of the FFP-SI are used for spectral analyses of the aerosol backscatter and the reference laser pulse. The reference signal is tapped from the outgoing laser and served as a zero velocity indicator. The Doppler shift is retrieved from a frequency response function Q, which is defined as the ratio of difference of the transmitted signal and the reflected signal to their sum. Taking advantages of high signal-to-noise ratio of the detectors and high spectral resolution of the FFP-SI, the Q spectra of the aerosol backscatter are reconstructed along the line-of-sight (LOS) of the telescope. By applying a least squares fit procedure to the measured Q spectra, the center frequencies and the bandwidths are obtained simultaneously. And then the Doppler shifts are determined relative to the center frequency of the reference signal. To eliminate the influence of temperature fluctuations on the FFP-SI, the FFP-SI is cased in a chamber with temperature stability of 0.001 during the measurement. Continuous LOS wind observations are carried out on two days at Hefei (31.843 N, 117.265 E), China. In the meantime, LOS wind measurements from the HSRWL show good agreement with the results from an ultrasonic wind sensor (Vaisala windcap WMT52). Due to the computational expensive of the convolution operation of the Q function, an empirical method is adopted to evaluate the quality of the measurements. The standard deviation of the wind speed is 0.76 m/s at the 1.8 km. The standard deviation of the retrieved bandwidth variation is 2.07 MHz at the 1.8 km.

astro-ph.IM

Micro-pulse upconversion Doppler lidar for wind and visibility detection in the atmospheric boundary layer

For the first time, a versatile, eyesafe, compact and direct detection Doppler lidar is developed using upconversion single-photon detection method. An all-fiber and polarization maintaining architecture is realized to guarantee the high optical coupling efficiency and the system stability. Using integrated-optic components, the conservation of etendue of the optical receiver is achieved by manufacturing a fiber-coupled periodically poled Lithium niobate waveguide and an all-fiber Fabry-Perot interferometer (FPI). The so-called double-edge direct detection is implemented using a single-channel FPI and a single upconversion detector, incorporating time-division multiplexing method. The relative error of the system is lower than 0.1% over 9 weeks. To show the robust of the system, atmospheric wind and visibility over 48 hours are detected in the boundary layer. In the intercomparison experiments, lidar shows good agreement with the ultrasonic wind sensor (Vaisala windcap WMT52), with standard deviation of 1.04 m/s in speed and 12.3° in direction.

astro-ph.IM

Photon-counting Brillouin optical time-domain reflectometry based on up-conversion detector and fiber Fabry-Perot scanning interferometer

A direct-detection Brillouin optical time-domain reflectometry (BOTDR) is proposed and demonstrated by using an up-conversion single-photon detector and a fiber Fabry-Perot scanning interferometer (FFP-SI). Taking advantage of high signal-to-noise ratio of the detector and high spectrum resolution of the FFP-SI, the Brillouin spectrum along a polarization maintaining fiber (PMF) is recorded on a multiscaler with a small data size directly. In contrast with conventional BOTDR adopting coherent detection, photon-counting BOTDR is simpler in structure and easier in data processing. In the demonstration experiment, characteristic parameters of the Brillouin spectrum including its power, spectral width and frequency center are analyzed simultaneously along a 10 km PMF at different temperature and stain conditions.

quant-ph

Long-range micro-pulse aerosol lidar at 1.5 um with an up-conversion single-photon detector

A micro-pulse lidar at eye-safe wavelength is constructed based on an up-conversion single-photon detector. The ultralow noise detector enables using integration technique to improve the signal-to-noise ratio of the atmospheric backscattering even at daytime. With the pulse energy of 110uJ, the pulse repetition rate of 15 kHz, the optical antenna diameter of 100 mm and integration time of 5 minutes, a horizontal detection range of 7 km is realized. In the demonstration experiment, atmospheric visibility over 24 hours is monitored continuously, with results in accordance with the weather forecasts.

physics.optics