SearcharxivSearch

arXiv subjects

Xiao-Peng Zhou

Publications and source records attributed to Xiao-Peng Zhou.

3 recordsLinked to original sources

Precision measurement and modelling of the threshold-free 210Pb β spectrum

Beta decay is a fundamental process that governs nuclear stability and serves as a sensitive probe of the weak interaction and possible physics beyond the Standard Model of particle physics. However, precise measurements of complete $β$ decay spectra, particularly at low energies, remain experimentally and theoretically challenging. Here we report a high-precision, threshold-free measurement of the full $β$ decay spectrum of 210Pb to excited states of 210Bi, using a transition-edge sensor (TES)-based micro-calorimeter. This approach enables the detection of $β$ particle energies from 0 keV up to their endpoint by coincidence summing with subsequent de-excitation energy, thereby eliminating reconstruction artifacts near zero energy that have traditionally limited low-energy spectral accuracy. To our knowledge, this is the first complete, high-precision $β$ decay spectrum from 0 keV. The data resolve theoretical uncertainties associated with the atomic quantum exchange (AQE) effect. An accompanying ab initio theoretical framework, incorporating atomic, leptonic, and nuclear components, predicts a statistically significant (7.2 {$σ$}) enhancement in $β$ emission probability near zero energy, in agreement with the measurement and in contrast to models that omit AQE corrections. These results provide a new benchmark for $β$ decay theory at low energies, deepen our understanding of the weak interaction, and establish a critical foundation for searches for new physics, including dark matter interactions and precision studies of neutrinos.

nucl-ex

Preparation and measurement of an $\rm ^{37}$Ar source for liquid xenon detector calibration

We present the preparation and measurement of the radioactive isotope $\rm ^{37}Ar$, which was produced using thermal neutrons from a reactor, as a calibration source for liquid xenon time projection chambers. $\rm ^{37}Ar$ is a low-energy calibration source with a half-life of 35.01 days, making it suitable for calibration in the low-energy region of liquid xenon dark-matter experiments. Radioactive isotope $\rm ^{37}Ar$ was produced by irradiating $\rm ^{36}Ar$ with thermal neutrons. It was subsequently measured in a gaseous xenon time projection chamber (GXe TPC) to validate its radioactivity. Our results demonstrate that $\rm ^{37}Ar$ is an effective and viable calibration source that offers precise calibration capabilities in the low-energy domain of xenon-based detectors.

physics.ins-det

Transition edge sensor based detector: from X-ray to $γ$-ray

The Transition Edge Sensor is extremely sensitive to the change of temperature, combined with the high-Z metal of a certain thickness, it can realize the high energy resolution measurement of particles such as X-rays. X-rays with energies below 10 keV have very weak penetrating ability, so only a few microns thick of gold or bismuth can obtain quantum efficiency higher than 70\%. Therefore, the entire structure of the TES X-ray detector in this energy range can be realized in the microfabrication process. However, for X-rays or gamma rays from 10 keV to 200 keV, sub-millimeter absorber layers are required, which cannot be realized by microfabrication process. This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems built by ShanghaiTech University, then focus on the introduction of the TES $γ$-ray detector, with absorber based on an sub-millimeter lead-tin alloy sphere. The detector has a quantum efficiency above 70\% near 100 keV, and an energy resolution of about 161.5eV@59.5keV.

physics.ins-det