Searcharxiv⌕ Search

arXiv subjects

Xiao-Yun Zhao

Publications and source records attributed to Xiao-Yun Zhao.

At least 19 recordsLinked to original sources

The trigger and localization system of SVOM-GRM

The Space multi-band Variable Object Monitor (SVOM) is an astronomical satellite jointly developed by China and France, primarily focused on the detection of gamma-ray bursts (GRBs) and transient sources. The SVOM satellite was launched on 22nd June, 2024 with four payloads installed onboard. As one of payload, GRM comprises 3 gamma-ray detectors (each detector has an effective area of approximately 200~cm$^{2}$) with distinct pointing directions, enabling the temporal and spectral measurements as well as localization of GRBs in the energy range of 15-5000 keV. This article firstly introduces the on-board localization algorithm design for GRM and presents preliminary test results. Then, leveraging abundant ground-based computational resources, a joint fitting method for spectral and localization analysis using Monte Carlo Markov Chain (MCMC) is implemented. In contrast to the on-board localization algorithm, the on-ground MCMC method comprehensively considers the influence of spectral characteristics, thereby mitigating systematic biases. Finally, a systematic analysis based on this method is provided, highlighting the localization and spectral measurement capabilities of GRM. The preliminary localization analysis result for the on-board detected GRB 240629A by both GRM and Fermi/GBM shows that the localization result (error$\sim$4.14$^{\circ}$) of GRM is consistent with the Fermi/GBM result.

astro-ph.IM↗

Study on the detector energy response of SVOM/GRM

The SVOM mission is specifically designed to for the detection and localization of Gamma-Ray Bursts (GRBs) and subsequent follow-up observations. Among the four telescopes installed on the SVOM satellite, the Gamma-Ray Monitor (GRM) plays a crucial role in capturing the prompt emission of GRBs due to its wide field of view (FOV) and broad energy range. Accurate determination of the detector's energy response is vital for analyzing GRM data, particularly considering the significant impact of the atmospheric albedo effect on this response. This research focuses on deriving the detector's energy response and establishing a calibration database for the GRM, with particular emphasis on investigating the atmospheric albedo effect. The study shows that the contribution of albedo photons to the detector's effective area depends strongly on the orientation of the GRD line of sight (LoS) relative to Earth and on the incident direction of the GRB. When the GRD LoS is anti-Earth oriented, the albedo effect is minimal, with the highest proportion of albedo effective area accounting for approximately 10% of the total effective area. This occurs when the incident angle of the GRB is nearly perpendicular to the LoS. Conversely, if the GRD LoS is not pointing away from Earth and the GRB arrives from angles greater than about 90$^{\circ}$, the albedo component can become predominant, contributing up to around 100% of the total effective area. This is especially pronounced in the 8-20 keV range, where the direct effective area drops to zero due to the large GRB injection angle. Our results show that, it is necessary for GRM to consider the atmospheric albedo effects in detector response, otherwise the spectral and localization analyses will result in biased measurements.

astro-ph.HE↗

The Gamma-Ray Monitor onboard the SVOM satellite

The Gamma-Ray Monitor (GRM) is a key scientific payload onboard the Space-based Multi-band Variable Object Monitor (SVOM) satellite, designed specifically for the detection and study of gamma-ray bursts (GRBs). Launched into a 625 km low-Earth orbit on 22 June 2024, GRM serves as a large-area, wide-field-of-view instrument capable of observing the hard X-ray and soft gamma-ray emissions in the energy range of 15 keV to 5 MeV. Its primary scientific objectives include: promptly triggering and localizing GRBs (with particular sensitivity to short-hard GRBs), measuring spectral and temporal properties of bursts, monitoring charged particle fluxes in orbit. GRM successfully detected its first GRB (GRB 240627B) on 27 June 2024, and has since maintained a detection rate of more than 100 GRBs per year. Cross-instrument comparisons with detectors such as GECAM and Fermi/GBM have validated the performance and data quality of GRM. This paper provides a comprehensive overview of GRM instrument design, reliability verification through ground testing, in-orbit triggering and localization algorithms, performance calibration, and preliminary in-orbit results, demonstrating its capability as a versatile gamma-ray all-sky monitor.

astro-ph.IM↗

GRM Scientific Pipeline

The Gamma-Ray Monitor (GRM) is a key payload of the Space-based multiband astronomical Variable Objects Monitor (SVOM) mission, which is designed to detect gamma ray bursts (GRBs) within the energy range of 15 keV to 5 MeV. The GRM Instrument Center (GRM\_IC) features real-time data processing through the X-band, enabling rapid response of high-energy GRB events. The system employs an event-driven architecture and distributed design, achieving efficient processing and real-time monitoring of massive observational data. Through comprehensive data production processes and scientific data product management, the system achieves efficient production of scientific data products of the L1B / C level through the submission of jobs to the task scheduling system. Through modular architecture design and automated processing workflow, the GRM data processing system realizes precise conversion and scientific analysis of GRB detection data, providing robust technical support for future system upgrades and cross-platform collaboration.

astro-ph.IM↗

GECAM discovery of a peculiar magnetar X-ray burst (MXB 221120) from SGR J1935+2154 associated with a fast radio burst

Fast radio bursts (FRBs) are enigmatic cosmic transients of millisecond duration observed in the radio band. The identification of FRB-associated magnetar X-ray bursts (MXBs) from galactic magnetar SGR J1935+2154 suggests that at least a fraction of FRBs can be produced from magnetar activity. However, the sample size of FRB-associated MXBs is still very small. Here we report a bright and peculiar FRB-associated MXB from SGR J1935+2154 detected by GECAM on November 20, 2022, dubbed MXB 221120. We find that both temporal and spectral properties of MXB 221120 exhibit distinctive features. Its light curve could be generally described by a single FRED function with superposition of several narrow pulses. Interestingly, we identify a possible QPO feature with center frequency of ~18 Hz in this MXB. The time-integrated spectrum is best fitted by a blackbody model with temperature (kT ) of 18.6 keV, rendering it the first thermal spectrum FRB-associated MXB from SGR J1935+2154. Compared to other MXBs with single emission episode, MXB 221120 has longer duration and higher blackbody temperature, making it an outlier in the burst sample. These results indicate that MXB 221120 may be produced by a special mechanism with extreme physical conditions.

astro-ph.HE↗

Comprehensive Measurement of Spectral Evolution in a GRB Flare: High Time-Resolution Insights into the "Double-Tracking" Phenomenon

The spectral evolution characteristics of the prompt emission in gamma-ray bursts (GRBs) have been extensively studied, but detailed investigations of spectral evolution in a GRB flare remain lacking. In this work, we present the first analysis of spectral parameter evolution in a GRB flare through high time-resolved spectral fitting of the Brightest Flare in GRB 221009A. We find that the $α$-Flux, $E_p$-Flux, and $E_p$-$α$ relationships during both the overall phase and the rise phase of flare can be well described by simple power-law model, showing positive correlations. Therefore, we conclude that Brightest Flare exhibits "Double-tracking" behavior. Since values of $α$ do not exceed the synchrotron "death line" (-2/3), we explain this phenomenon using a magnetic dissipation synchrotron radiation model. In the decay phase of flare, the $E_p$-Flux and $E_p$-$α$ correlations become notably flatter, with their power-law indices decreasing significantly compared to those in the rise phase. This may be due to the fact that the next flare begins to erupt before the Brightest Flare has completely ended, resulting in the combined effects of both two flares. Our study of spectral parameter relations of the Brightest Flare provides new insights into the radiation mechanisms of both GRB prompt emission and flares.

astro-ph.HE↗

Performance of the Gamma-ray Transient Monitor at the IHEP Electron-Beam Facility

Gamma-Ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite, with the scientific objective of detecting gamma-ray bursts in the energy range of 20 keV to 1 MeV. GTM is equipped with five Gamma-Ray Transient Probes (GTPs), utilizing NaI(Tl) scintillators coupled with silicon photomultiplier (SiPM) arrays for signal readout. To test the performance of the GTP in detecting electrons, we used the IHEP Electron-Beam Facility (a continuous-energy-tunable, low-current, quasi-single-electron accelerator) for ground-based electron tests of the GTP. This paper provides a detailed description of the operating principles of the electron accelerator and presents the process and results of the GTP electron-beam tests. The test results show that the GTP has a dead time of less than 4 $μ$s for normal signals and approximately 70 $μ$s for overflow signals, consistent with the design specifications. The time-recording capability of the GTP was tested and found to be normal, with accurate recording of overflow events. The GTP's response to electrons in the 0.4-1.4 MeV range is also normal. Additionally, we used Geant4 to simulate the GTP's energy response and performed a comparative analysis of the simulation and experimental results. The performance tests and ground-based electron calibration validated the design of the GTP and enhanced the GTP's mass model, laying the foundation for payload development, in-orbit observation strategies, and scientific data analysis.

astro-ph.IM↗

GECAM discovery of the second FRB-associated Magnetar X-ray Burst from SGR J1935+2154

Fast radio burst (FRB) is mysterious phenomenon with millisecond-duration radio pulses observed mostly from cosmological distance. The association between FRB 200428 and a magnetar X-ray burst (MXB) from SGR J1935+2154 has significantly advanced the understanding of FRB and magnetar bursts. However, it is uncertain whether this association between MXB and FRB (i.e. MXB/FRB 200428) is genuine or just coincidental only based on this single event. Here we report the discovery of a bright ($\rm\sim7.6\times10^{-7}\,erg \cdot cm^{-2}$ in 1-250 keV) magnetar X-ray burst detected by GECAM on October 14th, 2022 (dubbed as MXB 221014) from SGR J1935+2154, which is associated with a FRB detected by CHIME and GBT. We conducted a detailed temporal and spectral analysis of MXB 221014 with GECAM data and find that it is a bright and typical ($T_{90}\sim$250 ms) X-ray burst from this magnetar. Interestingly, we find two narrow X-ray pulses in the MXB, one of which temporally aligns with the main pulse of the FRB 221014 $\sim5.70$ ms latter than the peak time of FRB 221014), resembling the feature found in MXB/FRB 200428. Furthermore, we did comprehensive comparison between MXB/FRB 221014 and MXB/FRB 200428, and find that while the two events share several common features, they also exhibit distinct differences, highlighting the variety of the MXB-FRB association morphology. This finding not only confirms the association between MXB and FRB but also provides new insights into the mechanism of and the relationship between FRB and MXB.

astro-ph.HE↗

Systematic Study of the Simultaneous Events Detected by GECAM

GECAM is a constellation of all-sky monitors in hard X-ray and gamma-ray band primarily aimed at high energy transients such as gamma-ray bursts, soft gamma-ray repeaters, solar flares and terrestrial gamma-ray flashes. As GECAM has the highest temporal resolution (0.1~$μ$s) among instruments of its kind, it can identify the so-called simultaneous events (STE) that deposit signals in multiple detectors nearly at the same time (with a 0.3~$μ$s window). However, the properties and origin of STE have not yet been explored. In this work, we implemented, for the first time, a comprehensive analysis of the STE detected by GECAM, including their morphology, energy deposition, and the dependence on the geomagnetic coordinates. We find that these STE probably result from direct interactions between high-energy charged cosmic rays and satellite. These results demonstrate that GECAM can detect, identify, and characterize high-energy cosmic rays, making it a Micro Cosmic-Ray Observatory (MICRO) in low Earth orbit.

astro-ph.HE↗

Brightest GRB flare observed in GRB 221009A: bridge the last gap between flare and prompt emission in GRB

Flares are usually observed during the afterglow phase of Gamma-Ray Bursts (GRBs) in soft X-ray, optical and radio bands, but rarely in gamma-ray band. Despite the extraordinary brightness, GECAM-C has accurately measured both the bright prompt emission and flare emission of GRB 221009A without instrumental effects, offering a good opportunity to study the relation between them. In this work, we present a comprehensive analysis of flare emission of GRB 221009A, which is composed of a series of flares. Among them, we identify an exceptionally bright flare with a record-breaking isotropic energy $E_{\rm iso} = 1.82 \times 10^{53}$ erg of GRB flares. It exhibits the highest peak energy ever detected in GRB flares, $E_{\rm peak} \sim 300$ keV, making it a genuine gamma-ray flare. It also shows rapid rise and decay timescales, significantly shorter than those of typical X-ray flares observed in soft X-ray or optical band, but comparable to those observed in prompt emissions. Despite these exceptional properties, the flare shares several common properties with typical GRB flares. We note that this is the first observation of a GRB flare in the keV-MeV band with sufficiently high temporal resolution and high statistics, which bridges the last gap between prompt emission and flare.

astro-ph.HE↗

LUNCH: A Lightweight Unified Deep-Learning Framework for General Transients Classification in High-Energy Time-Domain Astronomy

The increasing data volume of high-energy space monitors necessitates real-time, automated transient classification for multi-messenger follow-up. Conventional methods rely on empirical features like hardness ratios and reliable localization, which are not always precisely available during early detection. We developed the Lightweight Unified Neural Classifier for High-energy Transients (LUNCH) - an end-to-end deep-learning framework that performs general transient classification directly from raw multi-band light curves, eliminating the need for background subtraction or source localization. Its dual-scale architecture fuses long- and short-scale temporal evolution adaptively. Evaluated on 15 years of Fermi/GBM triggers, the optimal model achieves 97.23% accuracy when trained on complete energy spectra. A lightweight version using only three broad energy bands retains 95.07% accuracy, demonstrating that coarse spectral information fused with temporal context enables robust discrimination. The system significantly outperforms the GBM in-flight classifier on three months of independent test data. Feature visualization reveals well-separated class clusters, confirming physical interpretability. LUNCH combines high accuracy, low computational cost, and instrument-agnostic inputs, offering a practical solution for real-time in-flight processing that enables timely triggers for immediate multi-wavelength and multi-messenger follow-up observations in future time-domain missions.

astro-ph.IM↗

Revisit the periodicity of SGR J1935+2154 bursts with updated sample

Since FRB 200428 has been found to be associated with an X-ray burst from the Galactic magnetar SGR J1935+2154, it is interesting to explore whether the magnetar bursts also follow the similar active periodic behavior as some repeating FRBs. Previous studies show that there is possible period about 230 day in SGR J1935+2154 bursts. Here, we collected an updated burst sample from SGR J1935+2154, including all bursts reported by Fermi/GBM and GECAM till 2022 January. We also developed a targeted search pipeline to reveal more bursts from SGR J1935+2154 in the Fermi/GBM data from 2008 August to 2014 December (i.e. before the first burst detected by Swift/BAT). With this burst sample, we re-analyzed the possible periodicity of SGR J1935+2154 bursts using the Period Folding and Lomb-Scargle Periodogram methods. Our results show that the periodicity $\sim$238 day reported in literature is probably fake and the observation effects may introduce false periods (i.e. 55 day) according to simulation tests. We find that, for the current burst sample, the most probable period is 126.88$\pm$2.05 day, which could be interpreted as the precession of the magnetar. However, we note that the whole burst history is very complicated and difficult to be perfectly accommodated with any period reported thus far, therefore more monitoring observations of SGR J1935+2154 are required to test any periodicity hypothesis.

astro-ph.HE↗

GECAM Observations of the Galactic Magnetar SGR J1935+2154 during the 2021 and 2022 Burst Active Episodes. I. Burst Catalog

Magnetar is a neutron star with an ultrahigh magnetic field ($\sim 10^{14}-10^{15}$ G). The magnetar SGR J1935+2154 is not only one of the most active magnetars detected so far, but also the unique confirmed source of fast radio bursts (FRBs). Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to monitor gamma-ray transients all over the sky, including magnetar short bursts. Here we report the GECAM observations of the burst activity of SGR J1935+2154 from January 2021 to December 2022, which results in a unique and valuable data set for this important magnetar. With a targeted search of GECAM data, 159 bursts from SGR J1935+2154 are detected by GECAM-B while 97 bursts by GECAM-C, including the X-ray burst associated with a bright radio burst. We find that both the burst duration and the waiting time between two successive bursts follow lognormal distributions. The period of burst activity is $134\pm20$ days, thus the burst activity could be generally divided into four active episodes over these two years. Interestingly, the hardness ratio of X-ray bursts tends to be softer during these two years, especially during the active episode with radio bursts detected.

astro-ph.HE↗

GRB 240715A: Revealing Novel Intrinsic Mechanism by Different Individual Pulse

The Space-based multiband astronomical Variable Objects Monitor (SVOM), detected its first short gamma-ray burst, GRB 240715A, in-flight, which was jointly observed by Fermi. Based on observational data of SVOM/GRM and Fermi/GBM, we perform a comprehensive temporal and spectral analysis for individual pulse in the prompt emission of this burst, and novel characteristics are revealed. Firstly, opposite evolutions of spectral lag are found in the first and third pulse of this burst. Second, the large negative lag of the first pulse is an outlier in short GRB sample, especially when the pulse duration is considered. Spectral analysis shows that the negative lag of the first pulse is caused by the evolution of spectrum index, and is irrelevant to Epeak, which is inconsistent with the previous study. The intrinsic mechanism is probably attributed to electron cooling in the decaying magnetic field, which leads to the continuous hardening of the spectrum index and results in negative lag. Furthermore, spectral analysis also shows that the third pulse is more likely to be described by a quasi-thermal spectrum, indicating the existence of photospheric emission. It is difficult to explain how the synchrotron radiation appears before photospheric emission in a single GRB and some assumptions are discussed.

astro-ph.HE↗

A Method for Gamma-Ray Energy Spectrum Inversion and Correction

Accurate spectral analysis of high-energy astrophysical sources often relies on comparing observed data to incident spectral models convolved with the instrument response. However, for Gamma-Ray Bursts and other high-energy transient events observed at high count rates, significant distortions (e.g., pile-up, dead time, and large signal trailing) are introduced, complicating this analysis. We present a method framework to address the model dependence problem, especially to solve the problem of energy spectrum distortion caused by instrument signal pile-up due to high counting rate and high-rate effects, applicable to X-ray, gamma-ray, and particle detectors. Our approach combines physics-based Monte Carlo (MC) simulations with a model-independent spectral inversion technique. The MC simulations quantify instrumental effects and enable correction of the distorted spectrum. Subsequently, the inversion step reconstructs the incident spectrum using an inverse response matrix approach, conceptually equivalent to deconvolving the detector response. The inversion employs a Convolutional Neural Network, selected for its numerical stability and effective handling of complex detector responses. Validation using simulations across diverse input spectra demonstrates high fidelity. Specifically, for 27 different parameter sets of the brightest gamma-ray bursts, goodness-of-fit tests confirm the reconstructed spectra are in excellent statistical agreement with the input spectra, and residuals are typically within $\pm 2σ$. This method enables precise analysis of intense transients and other high-flux events, overcoming limitations imposed by instrumental effects in traditional analyses.

astro-ph.HE↗

BREAKFAST: A Framework for general joint BA duty and follow-up guidance of multiple $γ$-ray monitors

With the growing number of gamma-ray monitors in operation, several research teams have adopted a strategy of joint operation and scientific duty to improve efficiency. A successful example is the GECAM-HXMT-SVOM (GHS) constellation collaboration, which sets a precedent for other gamma-ray monitor constellations. However, joint duty also presents challenges to Burst Advocates (BAs), including the increased number of triggers and, more importantly, the frequent switching between various systems due to incompatibilities among different missions, which complicates the situation. To address the current requirements of multi-wavelength and multi-messenger astronomy, we developed a customized framework for unified trigger processing within the GHS joint duty, named "BA's Rapid Evaluation and Analysis Kit for Formulating Alerts and Summary Tools" (BREAKFAST). This framework incorporates a series of automated, semi-automated, and manual pipelines designed to rapidly process triggers of prompt emissions in the gamma-ray band from different instruments, while maintaining flexible compatibility for future missions. The pursuit of BREAKFAST goes beyond merely providing trigger processing for BAs. BREAKFAST also aims to filtering high-value targets and guiding follow-up telescopes through rapid analysis and reporting, thus serving as an important bridge between prompt emission observations and afterglow observations. To this end, a suite of comprehensive analysis modules is included in BREAKFAST, particularly the specially designed module that predicts X-ray afterglow brightness based on prompt emission properties. The framework's effectiveness has already been demonstrated in recent observational campaigns, and it is expected to play a significant role in the discovery and observation of peculiar transients in the future.

astro-ph.IM↗

Unveil A Peculiar Light Curve Pattern of Magnetar Burst with GECAM observations of SGR J1935+2154

Magnetar X-ray Burst (MXB) is usually composed of a single pulse or multiple pulses with rapid rise and brief duration mostly observed in hard X-ray (soft gamma-ray) band. Previous work studied the temporal behavior of some magnetar bursts and employed the Fast Rise Exponential Decay (FRED) model to fit pulses of MXB. However, whether there is other kind of pulse shape has not been explored. In this study, we systematically examined light curve of MXBs from SGR J1935+2154 detected by GECAM between 2021 and 2022. We find that there are different light curve morphologies. Especially, we discover a peculiar and new pattern, Exponential Rise and Cut-Off Decay (ERCOD), which is significantly different from FRED and could be well described by a mathematical function we proposed. We find that MXBs with ERCOD shape are generally longer in duration, brighter in the peak flux, and harder in spectrum. We note that the ERCOD shape is not unique to SGR J1935+2154 but also present in other magnetars. This new light curve pattern may imply a special burst and radiation mechanism of magnetar.

astro-ph.HE↗

Multi-Instrument Search for Gamma-Ray Counterpart of X-ray Transients detected by EP/WXT

As a soft X-ray imager with unprecedentedly large field of view, EP/WXT has detected many (fast) X-ray transients, whose nature is very intriguing. Whether there is gamma-ray counterpart for the X-ray transient provides important implications for its origin. Some of them have been reported to be associated with GRB, however, a systematic study on the gamma-ray emission of these X-ray transients is lacking. In this work, we implemented a comprehensive targeted search for gamma-ray counterparts to 63 X-ray transients reported by EP/WXT during its first year of operation, using the dedicated multiple-instrument search pipeline, ETJASMIN, with GECAM-B, GECAM-C, Fermi/GBM, and \textit{Insight}-HXMT data. We find that 14 out of 63 (22\%) EP/WXT X-ray transients have gamma-ray counterparts. For other transients, ETJASMIN pipeline provided upper limit of gamma-ray emission, which is more stringent than that given by individual instrument. Moreover, we investigated the properties of the X-ray transients and their gamma-ray counterparts, and explored the relation between the x-ray transient and gamma-ray counterpart.

astro-ph.HE↗