SearcharxivSearch

arXiv subjects

Xiaoxiao Yan

Publications and source records attributed to Xiaoxiao Yan.

2 recordsLinked to original sources

Med-CMR: A Fine-Grained Benchmark Integrating Visual Evidence and Clinical Logic for Medical Complex Multimodal Reasoning

MLLMs MLLMs are beginning to appear in clinical workflows, but their ability to perform complex medical reasoning remains unclear. We present Med-CMR, a fine-grained Medical Complex Multimodal Reasoning benchmark. Med-CMR distinguishes from existing counterparts by three core features: 1) Systematic capability decomposition, splitting medical multimodal reasoning into fine-grained visual understanding and multi-step reasoning to enable targeted evaluation; 2) Challenging task design, with visual understanding across three key dimensions (small-object detection, fine-detail discrimination, spatial understanding) and reasoning covering four clinically relevant scenarios (temporal prediction, causal reasoning, long-tail generalization, multi-source integration); 3) Broad, high-quality data coverage, comprising 20,653 Visual Question Answering (VQA) pairs spanning 11 organ systems and 12 imaging modalities, validated via a rigorous two-stage (human expert + model-assisted) review to ensure clinical authenticity. We evaluate 18 state-of-the-art MLLMs with Med-CMR, revealing GPT-5 as the top-performing commercial model: 57.81 accuracy on multiple-choice questions (MCQs) and a 48.70 open-ended score, outperforming Gemini 2.5 Pro (49.87 MCQ accuracy, 45.98 open-ended score) and leading open-source model Qwen3-VL-235B-A22B (49.34 MCQ accuracy, 42.62 open-ended score). However, specialized medical MLLMs do not reliably outperform strong general models, and long-tail generalization emerges as the dominant failure mode. Med-CMR thus provides a stress test for visual-reasoning integration and rare-case robustness in medical MLLMs, and a rigorous yardstick for future clinical systems.

cs.AI

A flexible film thermocouple temperature sensor

This article introduces a thin-film thermocouple temperature sensor with symmetrical electrode structure. It uses PI film as a flexible substrate. Cu film and CuNi film made by MEMS manufacturing process as positive and negative electrodes. The device itself has the advantages of miniature, bendable and fast response speed. To reduce the film resistance value. Conducting metal film thickness and sputtering substrate temperature optimization experiments. The critical dimensions of Cu/CuNi film are 650nm and 400nm. The best sputtering substrate temperature for Cu/CuNi films is 100 degrees Celsius and 150 degrees Celsius. Testing the adhesion of thin film thermocouples using the peel-off method. The test result is 9.4N. Finally, the film thermocouple temperature sensor is subjected to a temperature static calibration experiment. The result shows that the actual potential difference error is within 1 degrees Celsius. It belongs to the second class standard in the formulation of thermocouple standards in my country. Through curve fitting, the corresponding relationship between temperature and potential difference is more accurate.

cond-mat.mtrl-sci