Searcharxiv⌕ Search

arXiv subjects

Xihan Ma

Publications and source records attributed to Xihan Ma.

9 recordsLinked to original sources

Beyond Future Views: Exploring Future-State World Models for Vision-Language Navigation

Vision-Language Navigation(VLN) requires an embodied agent to follow language instructions through unseen 3D environments, where the target spaces often lie beyond the current observation. Navigation world models address this challenge by predicting future views either as pixels or latent representations, providing valuable look-ahead information for action decision. Both paradigms define the future primarily through what the agent may observe, raising a fundamental question: is predicting future views the ultimate form to represent the future for VLN? Cognitive studies show that the human hippocampus prospectively represents both future goals and intervening locations along planned routes. Inspired by this predictive-map view, we organize the navigation-relevant future around goal-directed spatial states and route structure. We instantiate this perspective with two complementary abstractions: a short-horizon waypoint that specifies the next local state to reach, and a mid-horizon corridor that captures the spatial support of the upcoming route. Based on this design, we propose FS-Nav, a future-state world modeling framework that predicts waypoint-corridor states from spatial memory and language instructions, and communicates them to a VLM navigator through top-down and first-person interfaces. Experiments on standard VLN benchmarks demonstrate that FS-Nav achieves state-of-the-art performance. This highlights navigation-relevant future-state modeling as a promising direction for representing the future in VLN.

cs.RO↗

HoloBoxing: A Simple Recipe for Humanoid Boxing with 7 Minutes of Single-GPU Training

HoloBoxing presents a simple recipe for learning humanoid boxing by building on a pretrained whole-body controller. The recipe separates reusable motor skills from task decisions: a compact planner requests future body-point targets, while the frozen controller handles joint-level execution. A learned decoder maps 32-dimensional actions to structured target windows, and measured-state imitation initializes the planner before reinforcement learning. Task learning then refines interaction behavior while reusing the decoder and controller, avoiding the need to relearn whole-body control. This combination keeps task optimization focused on a compact upper policy and supplies an initial behavior before reward-driven exploration. Starting from that available controller, the recipe accounts for about seven minutes of additional training, including reused representation fitting and a single-GPU task run. This excludes controller pretraining, data preparation, evaluation, and search. Simulated boxing experiments and component controls evaluate the resulting behavior and the roles of imitation initialization and the target representation.

cs.RO↗

From Self-Normal-Positioning to Omni-Directional Tracking: Real-Time Surface Modeling Enabled Probe Tilt Control for Robotic Ultrasound Imaging

Ultrasound (US) provides real-time, radiation-free imaging, but the image quality depends strongly on how the probe is oriented against the patient body. Robotic US can reduce operator workload and improve acquisition consistency; however, most existing systems focus on normal positioning, where the probe is maintained perpendicular to the local surface. This constraint is inadequate for examinations like echocardiography, where obtaining a diagnostic view requires a non-normal probe angle. Consequently, a clinically useful robotic system must sense the local surface in real-time and preserve the desired probe orientation. Here, we propose an omni-directional probe-orientation control framework that integrates RGB-D perception, local-surface modeling, and task-space orientation control. The surface model fuses multi-view point clouds and provides a quadratic estimate of the local surface. A desired imaging direction is then encoded relative to the normal, enabling the probe to track arbitrary angles. The framework was evaluated through flat-surface tracking, phantom target-angle recovery, and in-vivo tracking of an expert selected view. Results show that the mean angular tracking error was 1.06 +- 0.66 deg. The system recovered a non-normal tilt angle of up to 44.39 +- 2.59 deg relative to the surface normal, and acquired the desired heart chamber view in the phantom and in-vivo experiments.

cs.RO↗

HoloMotion-1 Technical Report

In this report, we present HoloMotion-1, a humanoid motion foundation model for zero-shot whole-body motion tracking. A key innovation of HoloMotion-1 is to scale control-policy training with a large-scale hybrid motion corpus, where video-reconstructed motions from in-the-wild videos provide the dominant source of motion diversity, while curated motion-capture and in-house motion data provide higher-fidelity supervision and deployment-oriented coverage. This data regime enables HoloMotion-1 to move beyond conventional MoCap-only training and exposes the policy to substantially broader behaviors, capture conditions, and motion styles. Learning from such heterogeneous data introduces new challenges, including reconstruction noise, source-domain mismatch, uneven motion quality, and the need for temporal modeling under large behavioral variation. To address these challenges, HoloMotion-1 integrates large-capacity temporal modeling, a sparsely activated Mixture-of-Experts Transformer with KV-cache inference for real-time control, and a sequence-level training strategy that improves learning efficiency on extended motion sequences. Extensive experiments on multiple unseen motion benchmarks show that HoloMotion-1 generalizes robustly across diverse motion types and capture conditions, significantly improves tracking accuracy over prior methods, and transfers directly to a real humanoid robot without task-specific fine-tuning.

cs.RO↗

Towards Autonomous Robotic Kidney Ultrasound: Spatial-Efficient Volumetric Imaging via Template Guided Optimal Pivoting

Medical ultrasound (US) imaging is a frontline tool for the diagnosis of kidney diseases. However, traditional freehand imaging procedure suffers from inconsistent, operator-dependent outcomes, lack of 3D localization information, and risks of work-related musculoskeletal disorders. While robotic ultrasound (RUS) systems offer the potential for standardized, operator-independent 3D kidney data acquisition, the existing scanning methods lack the ability to determine the optimal imaging window for efficient imaging. As a result, the scan is often blindly performed with excessive probe footprint, which frequently leads to acoustic shadowing and incomplete organ coverage. Consequently, there is a critical need for a spatially efficient imaging technique that can maximize the kidney coverage through minimum probe footprint. Here, we propose an autonomous workflow to achieve efficient kidney imaging via template-guided optimal pivoting. The system first performs an explorative imaging to generate partial observations of the kidney. This data is then registered to a kidney template to estimate the organ pose. With the kidney localized, the robot executes a fixed-point pivoting sweep where the imaging plane is aligned with the kidney long axis to minimize the probe translation. The proposed method was validated in simulation and in-vivo. Simulation results indicate that a 60% exploration ratio provides optimal balance between kidney localization accuracy and scanning efficiency. In-vivo evaluation on two male subjects demonstrates a kidney localization accuracy up to 7.36 mm and 13.84 degrees. Moreover, the optimal pivoting approach shortened the probe footprint by around 75 mm when compared with the baselines. These results valid our approach of leveraging anatomical templates to align the probe optimally for volumetric sweep.

cs.RO↗

A-SEE2.0: Active-Sensing End-Effector for Robotic Ultrasound Systems with Dense Contact Surface Perception Enabled Probe Orientation Adjustment

Conventional freehand ultrasound (US) imaging is highly dependent on the skill of the operator, often leading to inconsistent results and increased physical demand on sonographers. Robotic Ultrasound Systems (RUSS) aim to address these limitations by providing standardized and automated imaging solutions, especially in environments with limited access to skilled operators. This paper presents the development of a novel RUSS system that employs dual RGB-D depth cameras to maintain the US probe normal to the skin surface, a critical factor for optimal image quality. Our RUSS integrates RGB-D camera data with robotic control algorithms to maintain orthogonal probe alignment on uneven surfaces without preoperative data. Validation tests using a phantom model demonstrate that the system achieves robust normal positioning accuracy while delivering ultrasound images comparable to those obtained through manual scanning. A-SEE2.0 demonstrates 2.47 ${\pm}$ 1.25 degrees error for flat surface normal-positioning and 12.19 ${\pm}$ 5.81 degrees normal estimation error on mannequin surface. This work highlights the potential of A-SEE2.0 to be used in clinical practice by testing its performance during in-vivo forearm ultrasound examinations.

cs.RO↗

SPADE: Spectroscopic Photoacoustic Denoising using an Analytical and Data-free Enhancement Framework

Spectroscopic photoacoustic (sPA) imaging uses multiple wavelengths to differentiate chromophores based on their unique optical absorption spectra. This technique has been widely applied in areas such as vascular mapping, tumor detection, and therapeutic monitoring. However, sPA imaging is highly susceptible to noise, leading to poor signal-to-noise ratio (SNR) and compromised image quality. Traditional denoising techniques like frame averaging, though effective in improving SNR, can be impractical for dynamic imaging scenarios due to reduced frame rates. Advanced methods, including learning-based approaches and analytical algorithms, have demonstrated promise but often require extensive training data and parameter tuning, limiting their adaptability for real-time clinical use. In this work, we propose a sPA denoising using a tuning-free analytical and data-free enhancement (SPADE) framework for denoising sPA images. This framework integrates a data-free learning-based method with an efficient BM3D-based analytical approach while preserves spectral linearity, providing noise reduction and ensuring that functional information is maintained. The SPADE framework was validated through simulation, phantom, ex vivo, and in vivo experiments. Results demonstrated that SPADE improved SNR and preserved spectral information, outperforming conventional methods, especially in challenging imaging conditions. SPADE presents a promising solution for enhancing sPA imaging quality in clinical applications where noise reduction and spectral preservation are critical.

cs.CV↗

Guiding the Last Centimeter: Novel Anatomy-Aware Probe Servoing for Standardized Imaging Plane Navigation in Robotic Lung Ultrasound

Navigating the ultrasound (US) probe to the standardized imaging plane (SIP) for image acquisition is a critical but operator-dependent task in conventional freehand diagnostic US. Robotic US systems (RUSS) offer the potential to enhance imaging consistency by leveraging real-time US image feedback to optimize the probe pose, thereby reducing reliance on operator expertise. However, determining the proper approach to extracting generalizable features from the US images for probe pose adjustment remain challenging. In this work, we propose a SIP navigation framework for RUSS, exemplified in the context of robotic lung ultrasound (LUS). This framework facilitates automatic probe adjustment when in proximity to the SIP. This is achieved by explicitly extracting multiple anatomical features presented in real-time LUS images and performing non-patient-specific template matching to generate probe motion towards the SIP using image-based visual servoing (IBVS). This framework is further integrated with the active-sensing end-effector (A-SEE), a customized robot end-effector that leverages patient external body geometry to maintain optimal probe alignment with the contact surface, thus preserving US signal quality throughout the navigation. The proposed approach ensures procedural interpretability and inter-patient adaptability. Validation is conducted through anatomy-mimicking phantom and in-vivo evaluations involving five human subjects. The results show the framework's high navigation precision with the probe correctly located at the SIP for all cases, exhibiting positioning error of under 2 mm in translation and under 2 degree in rotation. These results demonstrate the navigation process's capability to accomondate anatomical variations among patients.

cs.RO↗

Fast Adaptable Mobile Robot Navigation in Dynamic Environment

Autonomous navigation in dynamic environment heavily depends on the environment and its topology. Prior knowledge of the environment is not usually accurate as the environment keeps evolving in time. Since robot is continuously evaluating the environment as it proceeds, deciding the optimal way to traverse the environment to get to the goal, computationally efficient yet mathematically adaptive navigation algorithms are needed. In this paper, a navigation scheme for mobile robot, capable of dealing with time variant environment is proposed. This approach consists of a global planner (A*) and local planner (VFH) to assure an optimal and collision-free robot motion. The algorithm is tested both in simulation and experimentation in different environments that are known to result in failures in VFH and ROS navigation stack, for comparison purposes. Overall, the algorithm enables the robot to get to the goal faster and also produces a smoother path while doing so.

cs.RO↗